These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 17059548)

  • 1. Structural and mechanical properties of nanocrystalline titanium and 316LVM steel processed by hydrostatic extrusion.
    Garbacz H; Lewandowska M; Pachla W; Kurzydłowski KJ
    J Microsc; 2006 Sep; 223(Pt 3):272-4. PubMed ID: 17059548
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of TMCP parameters on the microstructure and mechanical properties of Ti-Nb microalloyed steel.
    Nowotnik A; Siwecki T
    J Microsc; 2010 Mar; 237(3):258-62. PubMed ID: 20500376
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of different types of investments on the alpha-case layer of titanium castings.
    Guilin Y; Nan L; Yousheng L; Yining W
    J Prosthet Dent; 2007 Mar; 97(3):157-64. PubMed ID: 17394914
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Titanium versus stainless steel for anterior spinal fusions: an analysis of rod stress as a predictor of rod breakage during physiologic loading in a bovine model.
    Wedemeyer M; Parent S; Mahar A; Odell T; Swimmer T; Newton P
    Spine (Phila Pa 1976); 2007 Jan; 32(1):42-8. PubMed ID: 17202891
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Corrosion resistance of nanostructured titanium.
    Garbacz H; Pisarek M; Kurzydłowski KJ
    Biomol Eng; 2007 Nov; 24(5):559-63. PubMed ID: 17889602
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microstructure evolution in age-hardenable aluminium alloy during processing by hydrostatic extrusion.
    Lewandowska M
    J Microsc; 2006 Oct; 224(Pt 1):34-7. PubMed ID: 17100901
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-strength, low-alloy steels.
    Rashid MS
    Science; 1980 May; 208(4446):862-9. PubMed ID: 17772810
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comprehensive Evaluation of the Properties of Ultrafine to Nanocrystalline Grade 2 Titanium Wires.
    Palán J; Procházka R; Džugan J; Nacházel J; Duchek M; Németh G; Máthis K; Minárik P; Horváth K
    Materials (Basel); 2018 Dec; 11(12):. PubMed ID: 30545032
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of different brazing and welding methods on tensile strength and microhardness of orthodontic stainless steel wire.
    Bock JJ; Fraenzel W; Bailly J; Gernhardt CR; Fuhrmann RA
    Eur J Orthod; 2008 Aug; 30(4):396-400. PubMed ID: 18617503
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thermal processing and characterization of 316LVM cardiovascular stent.
    Verma A; Choubey A; Raval A; Kothwala D
    Biomed Mater Eng; 2006; 16(6):381-95. PubMed ID: 17119277
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hydrated versus lyophilized forms of porcine extracellular matrix derived from the urinary bladder.
    Freytes DO; Tullius RS; Valentin JE; Stewart-Akers AM; Badylak SF
    J Biomed Mater Res A; 2008 Dec; 87(4):862-72. PubMed ID: 18228251
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical biocompatibilities of titanium alloys for biomedical applications.
    Niinomi M
    J Mech Behav Biomed Mater; 2008 Jan; 1(1):30-42. PubMed ID: 19627769
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microstructure and tensile properties after thermohydrogen processing of Ti-6 Al-4V.
    Guitar A; Vigna G; Luppo MI
    J Mech Behav Biomed Mater; 2009 Apr; 2(2):156-63. PubMed ID: 19627819
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of interface characterization and adhesion of glass ceramics to commercially pure titanium and gold alloy after thermal- and mechanical-loading.
    Vásquez VZ; Ozcan M; Kimpara ET
    Dent Mater; 2009 Feb; 25(2):221-31. PubMed ID: 18718654
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Titanium with aligned, elongated pores for orthopedic tissue engineering applications.
    Spoerke ED; Murray NG; Li H; Brinson LC; Dunand DC; Stupp SI
    J Biomed Mater Res A; 2008 Feb; 84(2):402-12. PubMed ID: 17618479
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Microstructure, mechanical properties and cytocompatibility of stable beta Ti-Mo-Ta sintered alloys.
    Delvat E; Gordin DM; Gloriant T; Duval JL; Nagel MD
    J Mech Behav Biomed Mater; 2008 Oct; 1(4):345-51. PubMed ID: 19627799
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants.
    Traini T; Mangano C; Sammons RL; Mangano F; Macchi A; Piattelli A
    Dent Mater; 2008 Nov; 24(11):1525-33. PubMed ID: 18502498
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fabrication and nanoindentation properties of TiN/NiTi thin films and their applications in electrochemical sensing.
    Kumar A; Singh D; Goyal RN; Kaur D
    Talanta; 2009 May; 78(3):964-9. PubMed ID: 19269458
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Production, microstructural characterization and mechanical properties of as-cast Ti-10Mo-xNb alloys.
    Gabriel SB; Nunes CA; Soares Gde A
    Artif Organs; 2008 Apr; 32(4):299-304. PubMed ID: 18370944
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.