These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

438 related articles for article (PubMed ID: 17060544)

  • 1. Usefulness of the external jugular vein examination in detecting abnormal central venous pressure in critically ill patients.
    Vinayak AG; Levitt J; Gehlbach B; Pohlman AS; Hall JB; Kress JP
    Arch Intern Med; 2006 Oct; 166(19):2132-7. PubMed ID: 17060544
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Usefulness of a central venous catheter during hepatic surgery.
    Stéphan F; Rezaiguia-Delclaux S
    Acta Anaesthesiol Scand; 2008 Mar; 52(3):388-96. PubMed ID: 18269388
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Physical examination, central venous pressure, and chest radiography for the prediction of transpulmonary thermodilution-derived hemodynamic parameters in critically ill patients: a prospective trial.
    Saugel B; Ringmaier S; Holzapfel K; Schuster T; Phillip V; Schmid RM; Huber W
    J Crit Care; 2011 Aug; 26(4):402-10. PubMed ID: 21273034
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Is external jugular venous pressure a good predictor of volume status in kidney graft recipients?
    Trzebicki J; Flakiewicz E; Nowakowski P; Kosieradzki M; Lisik W; Chmura A
    Transplant Proc; 2009 Oct; 41(8):3033-5. PubMed ID: 19857669
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Non-invasive evaluation of central venous pressure derived from respiratory variations in the diameter of the inferior vena cava].
    Minutiello L
    Minerva Cardioangiol; 1993 Oct; 41(10):433-7. PubMed ID: 8302439
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The sensitivity and specificity of ultrasound estimation of central venous pressure using the internal jugular vein.
    Siva B; Hunt A; Boudville N
    J Crit Care; 2012 Jun; 27(3):315.e7-11. PubMed ID: 22137379
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diagnostic accuracy of a simple ultrasound measurement to estimate central venous pressure in spontaneously breathing, critically ill patients.
    Keller AS; Melamed R; Malinchoc M; John R; Tierney DM; Gajic O
    J Hosp Med; 2009 Jul; 4(6):350-5. PubMed ID: 19670356
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A technique for central venous pressure measurement in normal horses.
    Wilsterman S; Hackett ES; Rao S; Hackett TB
    J Vet Emerg Crit Care (San Antonio); 2009 Jun; 19(3):241-6. PubMed ID: 19691508
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound accurately reflects the jugular venous examination but underestimates central venous pressure.
    Deol GR; Collett N; Ashby A; Schmidt GA
    Chest; 2011 Jan; 139(1):95-100. PubMed ID: 20798190
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The intrathoracic blood volume index as an indicator of fluid responsiveness in critically ill patients with acute circulatory failure: a comparison with central venous pressure.
    Muller L; Louart G; Bengler C; Fabbro-Peray P; Carr J; Ripart J; de La Coussaye JE; Lefrant JY
    Anesth Analg; 2008 Aug; 107(2):607-13. PubMed ID: 18633040
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thrombosis of the superior vena cava and auxiliary branches in patients with indwelling catheterization of the internal jugular vein.
    Li H; Wang SX; Wang W; Xu C; Shen S; Yu L; Zhang GZ
    Chin Med J (Engl); 2009 Mar; 122(6):692-6. PubMed ID: 19323936
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Can peripheral venous pressure be an alternative to central venous pressure during right hepatectomy in living donors?
    Choi SJ; Gwak MS; Ko JS; Kim GS; Kim TH; Ahn H; Kim JA; Yang M; Lee S; Kim M
    Liver Transpl; 2007 Oct; 13(10):1414-21. PubMed ID: 17902127
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prospective evaluation of intravascular volume status in critically ill patients: does inferior vena cava collapsibility correlate with central venous pressure?
    Stawicki SP; Adkins EJ; Eiferman DS; Evans DC; Ali NA; Njoku C; Lindsey DE; Cook CH; Balakrishnan JM; Valiaveedan S; Galwankar SC; Boulger CT; Springer AN; Bahner DP
    J Trauma Acute Care Surg; 2014 Apr; 76(4):956-63; discussion 963-4. PubMed ID: 24662857
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of the right external jugular vein as the preferred access site when the right internal jugular vein is not usable.
    Cho SK; Shin SW; Do YS; Park KB; Choo SW; Choo IW
    J Vasc Interv Radiol; 2006 May; 17(5):823-9. PubMed ID: 16687748
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Use of Internal Jugular Vein Ultrasonography to Anticipate Low or High Central Venous Pressure During Mechanical Ventilation.
    Hilbert T; Ellerkmann RK; Klaschik S; Putensen C; Thudium M
    J Emerg Med; 2016 Apr; 50(4):581-7. PubMed ID: 26806319
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Noninvasive central venous pressure measurement by controlled compression sonography at the forearm.
    Thalhammer C; Aschwanden M; Odermatt A; Baumann UA; Imfeld S; Bilecen D; Marsch SC; Jaeger KA
    J Am Coll Cardiol; 2007 Oct; 50(16):1584-9. PubMed ID: 17936158
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Volume assessment in patients with necrotizing pancreatitis: a comparison of intrathoracic blood volume index, central venous pressure, and hematocrit, and their correlation to cardiac index and extravascular lung water index.
    Huber W; Umgelter A; Reindl W; Franzen M; Schmidt C; von Delius S; Geisler F; Eckel F; Fritsch R; Siveke J; Henschel B; Schmid RM
    Crit Care Med; 2008 Aug; 36(8):2348-54. PubMed ID: 18596637
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of peripheral and central venous pressure in awake dogs and cats.
    Chow RS; Kass PH; Haskins SC
    Am J Vet Res; 2006 Dec; 67(12):1987-91. PubMed ID: 17144798
    [TBL] [Abstract][Full Text] [Related]  

  • 19. External jugular Groshong catheter is associated with fewer complications than a subclavian Argyle catheter.
    Ishizuka M; Nagata H; Takagi K; Horie T; Furihata M; Nakagawa A; Kubota K
    Eur Surg Res; 2008; 40(2):197-202. PubMed ID: 17998779
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pressure measurements during cardiac surgery--internal jugular vs central venous.
    Alemohammad M; Khan ZH; Sanatkar M; Mirkhani SH; Ghorbandaie-Poure I
    Middle East J Anaesthesiol; 2005 Jun; 18(2):357-65. PubMed ID: 16438010
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.