These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
210 related articles for article (PubMed ID: 17060762)
1. Effectiveness of negative pressure closure in the integration of split thickness skin grafts: a randomized, double-masked, controlled trial. Llanos S; Danilla S; Barraza C; Armijo E; Piñeros JL; Quintas M; Searle S; Calderon W Ann Surg; 2006 Nov; 244(5):700-5. PubMed ID: 17060762 [TBL] [Abstract][Full Text] [Related]
2. A prospective randomized controlled trial comparing negative pressure dressing and conventional dressing methods on split-thickness skin grafts in burned patients. Petkar KS; Dhanraj P; Kingsly PM; Sreekar H; Lakshmanarao A; Lamba S; Shetty R; Zachariah JR Burns; 2011 Sep; 37(6):925-9. PubMed ID: 21723044 [TBL] [Abstract][Full Text] [Related]
3. Prospective randomized controlled trial comparing two methods of securing skin grafts using negative pressure wound therapy: vacuum-assisted closure and gauze suction. Nguyen TQ; Franczyk M; Lee JC; Greives MR; O'Connor A; Gottlieb LJ J Burn Care Res; 2015; 36(2):324-8. PubMed ID: 25162948 [TBL] [Abstract][Full Text] [Related]
4. Delayed primary closure of the burn wounds. Prasanna M; Mishra P; Thomas C Burns; 2004 Mar; 30(2):169-75. PubMed ID: 15019128 [TBL] [Abstract][Full Text] [Related]
5. Effects of human recombinant growth hormone on donor-site healing in burned adults. Losada F; García-Luna PP; Gómez-Cía T; Garrido M; Pereira JL; Marín F; Astorga R World J Surg; 2002 Jan; 26(1):2-8. PubMed ID: 11898025 [TBL] [Abstract][Full Text] [Related]
6. Vacuum-assisted closure therapy as a pretreatment for split thickness skin grafts. Saaiq M; Hameed-Ud-Din ; Khan MI; Chaudhery SM J Coll Physicians Surg Pak; 2010 Oct; 20(10):675-9. PubMed ID: 20943111 [TBL] [Abstract][Full Text] [Related]
7. The use of Suprathel(®) in deep dermal burns: first results of a prospective study. Keck M; Selig HF; Lumenta DB; Kamolz LP; Mittlböck M; Frey M Burns; 2012 May; 38(3):388-95. PubMed ID: 22078803 [TBL] [Abstract][Full Text] [Related]
9. Effect of amniotic membrane on graft take in extremity burns. Mohammadi AA; Johari HG; Eskandari S Burns; 2013 Sep; 39(6):1137-41. PubMed ID: 23523222 [TBL] [Abstract][Full Text] [Related]
10. Application of topical negative pressure (vacuum-assisted closure) to split-thickness skin grafts: a structured evidence-based review. Azzopardi EA; Boyce DE; Dickson WA; Azzopardi E; Laing JH; Whitaker IS; Shokrollahi K Ann Plast Surg; 2013 Jan; 70(1):23-9. PubMed ID: 23249474 [TBL] [Abstract][Full Text] [Related]
11. Use of a home vacuum-assisted closure device in the burn population is both cost-effective and efficacious. Mushin OP; Bogue JT; Esquenazi MD; Toscano N; Bell DE Burns; 2017 May; 43(3):490-494. PubMed ID: 28256293 [TBL] [Abstract][Full Text] [Related]
12. An improved alternative to vacuum-assisted closure (VAC) as a negative pressure dressing in lower limb split skin grafting: a clinical trial. Rozen WM; Shahbaz S; Morsi A J Plast Reconstr Aesthet Surg; 2008; 61(3):334-7. PubMed ID: 18267313 [TBL] [Abstract][Full Text] [Related]
13. Negative-pressure closure was superior to tie-over technique for stabilization of split-thickness skin graft in large or muscle-exposing defects: A retrospective study. Nakamura Y; Fujisawa Y; Ishitsuka Y; Tanaka R; Maruyama H; Okiyama N; Watanabe R; Fujimoto M J Dermatol; 2018 Oct; 45(10):1207-1210. PubMed ID: 30010206 [TBL] [Abstract][Full Text] [Related]
15. The vacuum assisted closure device: a method of securing skin grafts and improving graft survival. Scherer LA; Shiver S; Chang M; Meredith JW; Owings JT Arch Surg; 2002 Aug; 137(8):930-3; discussion 933-4. PubMed ID: 12146992 [TBL] [Abstract][Full Text] [Related]
16. Demonstration of the safety and effectiveness of the RECELL Holmes JH; Molnar JA; Shupp JW; Hickerson WL; King BT; Foster KN; Cairns BA; Carter JE Burns; 2019 Jun; 45(4):772-782. PubMed ID: 30578048 [TBL] [Abstract][Full Text] [Related]
17. [Clinical application of human tissue engineered skin with full thickness on donor site of split thickness skin graft in burn wounds]. Liu Y; Jin Y; Hu D; Xu M; Dong M; Zhang Y; Xiao H Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2006 Feb; 20(2):169-71. PubMed ID: 16535795 [TBL] [Abstract][Full Text] [Related]
18. Negative pressure dressing assisted healing in pediatric burn patients. Koehler S; Jinbo A; Johnson S; Puapong D; de Los Reyes C; Woo R J Pediatr Surg; 2014 Jul; 49(7):1142-5. PubMed ID: 24952804 [TBL] [Abstract][Full Text] [Related]
19. [Clinical application of negative pressure dressing in the full-thickness skin grafting]. Liang PF; Hu JX; Zhang PH; Zhang MH; Ren LC; Zeng JZ; Zhou J; Guo L; Cui X; Huang MT; He ZY; Huang XY Zhonghua Shao Shang Za Zhi; 2018 Jul; 34(7):492-496. PubMed ID: 30060353 [No Abstract] [Full Text] [Related]
20. Cost-benefit analysis of outcomes from the use of fibrin sealant for fixation of skin grafts in small-size burns compared to staples as historical controls: a retrospective review. Butts CC; Sahawneh J; Duffy A; Curtis R; Mishra N; Frotan MA; Hodge J; Luterman A; Gulati S Ann Plast Surg; 2015 Feb; 74(2):173-5. PubMed ID: 25590248 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]