609 related articles for article (PubMed ID: 17065746)
1. Finite element analysis and stent design: Reduction of dogboning.
De Beule M; Van Impe R; Verhegghe B; Segers P; Verdonck P
Technol Health Care; 2006; 14(4-5):233-41. PubMed ID: 17065746
[TBL] [Abstract][Full Text] [Related]
2. Realistic finite element-based stent design: the impact of balloon folding.
De Beule M; Mortier P; Carlier SG; Verhegghe B; Van Impe R; Verdonck P
J Biomech; 2008; 41(2):383-9. PubMed ID: 17920068
[TBL] [Abstract][Full Text] [Related]
3. Cardiovascular stent design and vessel stresses: a finite element analysis.
Lally C; Dolan F; Prendergast PJ
J Biomech; 2005 Aug; 38(8):1574-81. PubMed ID: 15958213
[TBL] [Abstract][Full Text] [Related]
4. Suggestion of potential stent design parameters to reduce restenosis risk driven by foreshortening or dogboning due to non-uniform balloon-stent expansion.
Lim D; Cho SK; Park WP; Kristensson A; Ko JY; Al-Hassani ST; Kim HS
Ann Biomed Eng; 2008 Jul; 36(7):1118-29. PubMed ID: 18437572
[TBL] [Abstract][Full Text] [Related]
5. Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method.
Wang WQ; Liang DK; Yang DZ; Qi M
J Biomech; 2006; 39(1):21-32. PubMed ID: 16271584
[TBL] [Abstract][Full Text] [Related]
6. [Design optimization of endovascular stent by finite element method].
Wang W; Wang L; Yang D; Qi M
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Apr; 25(2):372-7. PubMed ID: 18610625
[TBL] [Abstract][Full Text] [Related]
7. On the finite element modelling of balloon-expandable stents.
Ju F; Xia Z; Sasaki K
J Mech Behav Biomed Mater; 2008 Jan; 1(1):86-95. PubMed ID: 19627774
[TBL] [Abstract][Full Text] [Related]
8. A predictive study of the mechanical behaviour of coronary stents by computer modelling.
Migliavacca F; Petrini L; Montanari V; Quagliana I; Auricchio F; Dubini G
Med Eng Phys; 2005 Jan; 27(1):13-8. PubMed ID: 15604000
[TBL] [Abstract][Full Text] [Related]
9. [Finite element analysis of the expansion behavior of coronary stents].
Wang W; Yang D; Qi M
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Dec; 23(6):1258-62, 1266. PubMed ID: 17228721
[TBL] [Abstract][Full Text] [Related]
10. Assessment of tissue prolapse after balloon-expandable stenting: influence of stent cell geometry.
Capelli C; Gervaso F; Petrini L; Dubini G; Migliavacca F
Med Eng Phys; 2009 May; 31(4):441-7. PubMed ID: 19109049
[TBL] [Abstract][Full Text] [Related]
11. Design optimization of stent and its dilatation balloon using kriging surrogate model.
Li H; Liu T; Wang M; Zhao D; Qiao A; Wang X; Gu J; Li Z; Zhu B
Biomed Eng Online; 2017 Jan; 16(1):13. PubMed ID: 28086895
[TBL] [Abstract][Full Text] [Related]
12. Finite element comparison of performance related characteristics of balloon expandable stents.
Donnelly EW; Bruzzi MS; Connolley T; McHugh PE
Comput Methods Biomech Biomed Engin; 2007 Apr; 10(2):103-10. PubMed ID: 18651276
[TBL] [Abstract][Full Text] [Related]
13. Biomaterial optimization in a percutaneous aortic valve stent using finite element analysis.
Kumar GV; Mathew L
Cardiovasc Revasc Med; 2009; 10(4):247-51. PubMed ID: 19815172
[TBL] [Abstract][Full Text] [Related]
14. Analysis of the stent expansion in a stenosed artery using finite element method: application to stent versus stent study.
Imani SM; Goudarzi AM; Ghasemi SE; Kalani A; Mahdinejad J
Proc Inst Mech Eng H; 2014 Oct; 228(10):996-1004. PubMed ID: 25406228
[TBL] [Abstract][Full Text] [Related]
15. Modeling of size dependent failure in cardiovascular stent struts under tension and bending.
Harewood FJ; McHugh PE
Ann Biomed Eng; 2007 Sep; 35(9):1539-53. PubMed ID: 17503185
[TBL] [Abstract][Full Text] [Related]
16. Multi-objective optimization of coronary stent using Kriging surrogate model.
Li H; Gu J; Wang M; Zhao D; Li Z; Qiao A; Zhu B
Biomed Eng Online; 2016 Dec; 15(Suppl 2):148. PubMed ID: 28155700
[TBL] [Abstract][Full Text] [Related]
17. Virtual optimization of self-expandable braided wire stents.
De Beule M; Van Cauter S; Mortier P; Van Loo D; Van Impe R; Verdonck P; Verhegghe B
Med Eng Phys; 2009 May; 31(4):448-53. PubMed ID: 19117791
[TBL] [Abstract][Full Text] [Related]
18. Simulation of a balloon expandable stent in a realistic coronary artery-Determination of the optimum modelling strategy.
Zahedmanesh H; John Kelly D; Lally C
J Biomech; 2010 Aug; 43(11):2126-32. PubMed ID: 20452594
[TBL] [Abstract][Full Text] [Related]
19. Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall.
Migliavacca F; Petrini L; Massarotti P; Schievano S; Auricchio F; Dubini G
Biomech Model Mechanobiol; 2004 Jun; 2(4):205-17. PubMed ID: 15029511
[TBL] [Abstract][Full Text] [Related]
20. Effects of stent design parameters on normal artery wall mechanics.
Bedoya J; Meyer CA; Timmins LH; Moreno MR; Moore JE
J Biomech Eng; 2006 Oct; 128(5):757-65. PubMed ID: 16995763
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]