21. Performance characteristics of 10 home mechanical ventilators in pressure-support mode: a comparative bench study. Battisti A; Tassaux D; Janssens JP; Michotte JB; Jaber S; Jolliet P Chest; 2005 May; 127(5):1784-92. PubMed ID: 15888859 [TBL] [Abstract][Full Text] [Related]
22. Bench testing of pressure support ventilation with three different generations of ventilators. Richard JC; Carlucci A; Breton L; Langlais N; Jaber S; Maggiore S; Fougère S; Harf A; Brochard L Intensive Care Med; 2002 Aug; 28(8):1049-57. PubMed ID: 12185424 [TBL] [Abstract][Full Text] [Related]
23. Performance of current intensive care unit ventilators during pressure and volume ventilation. Marchese AD; Sulemanji D; Chipman D; Villar J; Kacmarek RM Respir Care; 2011 Jul; 56(7):928-40. PubMed ID: 21352662 [TBL] [Abstract][Full Text] [Related]
24. [A study of 3 new ventilators for anesthesia: a series of tests]. Beydon L; Liu N Ann Fr Anesth Reanim; 1994; 13(6):807-10. PubMed ID: 7668419 [TBL] [Abstract][Full Text] [Related]
25. Trigger performance of five pediatric home ventilators and one ICU ventilator depending on circuit type and system leak in a physical model of the lung. Baumgartner J; Schmidt J; Klotz D; Schneider H; Schumann S; Fuchs H Pediatr Pulmonol; 2022 Mar; 57(3):744-753. PubMed ID: 34910384 [TBL] [Abstract][Full Text] [Related]
26. Trigger performance of mid-level ICU mechanical ventilators during assisted ventilation: a bench study. Ferreira JC; Chipman DW; Kacmarek RM Intensive Care Med; 2008 Sep; 34(9):1669-75. PubMed ID: 18542923 [TBL] [Abstract][Full Text] [Related]
27. Work of breathing, inspiratory flow response, and expiratory resistance during continuous positive airway pressure with the ventilators EVITA-2, EVITA-4 and SV 300. Calzia E; Lindner KH; Stahl W; Martin A; Radermacher P; Georgieff M Intensive Care Med; 1998 Sep; 24(9):931-8. PubMed ID: 9803329 [TBL] [Abstract][Full Text] [Related]
28. Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning. Patel RG; Petrini MF Chest; 1998 Nov; 114(5):1390-6. PubMed ID: 9824020 [TBL] [Abstract][Full Text] [Related]
29. Inside anesthesia breathing circuits: time to reach a set sevoflurane concentration in toddlers and newborns: simulation using a test lung. Kern D; Larcher C; Basset B; Alacoque X; Fesseau R; Samii K; Minville V; Fourcade O Anesth Analg; 2012 Aug; 115(2):310-4. PubMed ID: 22584556 [TBL] [Abstract][Full Text] [Related]
31. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment]. Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533 [TBL] [Abstract][Full Text] [Related]
32. Effects of flow triggering on breathing effort during partial ventilatory support. Aslanian P; El Atrous S; Isabey D; Valente E; Corsi D; Harf A; Lemaire F; Brochard L Am J Respir Crit Care Med; 1998 Jan; 157(1):135-43. PubMed ID: 9445291 [TBL] [Abstract][Full Text] [Related]
33. Modification of a critical care ventilator for anesthesia use. Brown DL; Schulz J; Kirby RR Crit Care Med; 1987 Nov; 15(11):1055-7. PubMed ID: 3479292 [TBL] [Abstract][Full Text] [Related]
34. Performance of noninvasive ventilation modes on ICU ventilators during pressure support: a bench model study. Vignaux L; Tassaux D; Jolliet P Intensive Care Med; 2007 Aug; 33(8):1444-51. PubMed ID: 17563875 [TBL] [Abstract][Full Text] [Related]
35. Comparisons of predictive performance of breathing pattern variability measured during T-piece, automatic tube compensation, and pressure support ventilation for weaning intensive care unit patients from mechanical ventilation. Bien MY; Shui Lin Y; Shih CH; Yang YL; Lin HW; Bai KJ; Wang JH; Ru Kou Y Crit Care Med; 2011 Oct; 39(10):2253-62. PubMed ID: 21666447 [TBL] [Abstract][Full Text] [Related]
36. Effectiveness of Inspiratory Termination Synchrony with Automatic Cycling During Noninvasive Pressure Support Ventilation. Chen Y; Cheng K; Zhou X Med Sci Monit; 2016 May; 22():1694-701. PubMed ID: 27198165 [TBL] [Abstract][Full Text] [Related]
37. Battery duration of portable ventilators: effects of control variable, positive end-expiratory pressure, and inspired oxygen concentration. Campbell RS; Johannigman JA; Branson RD; Austin PN; Matacia G; Banks GR Respir Care; 2002 Oct; 47(10):1173-83. PubMed ID: 12354337 [TBL] [Abstract][Full Text] [Related]
38. Influences of Duration of Inspiratory Effort, Respiratory Mechanics, and Ventilator Type on Asynchrony With Pressure Support and Proportional Assist Ventilation. Vasconcelos RS; Sales RP; Melo LHP; Marinho LS; Bastos VP; Nogueira ADN; Ferreira JC; Holanda MA Respir Care; 2017 May; 62(5):550-557. PubMed ID: 28196936 [TBL] [Abstract][Full Text] [Related]
39. Critical evaluation of emergency stockpile ventilators in an in vitro model of pediatric lung injury. Custer JW; Watson CM; Dwyer J; Kaczka DW; Simon BA; Easley RB Pediatr Crit Care Med; 2011 Nov; 12(6):e357-61. PubMed ID: 21317679 [TBL] [Abstract][Full Text] [Related]
40. The effect of ventilator performance on airway pressure release ventilation: a model lung study. Yoshida T; Uchiyama A; Mashimo T; Fujino Y Anesth Analg; 2011 Sep; 113(3):529-33. PubMed ID: 21519042 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]