These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
272 related articles for article (PubMed ID: 17065888)
61. Contemporary anesthesia ventilators incur a significant "oxygen cost". Klemenzson GK; Perouansky M Can J Anaesth; 2004; 51(6):616-20. PubMed ID: 15197125 [TBL] [Abstract][Full Text] [Related]
62. Accuracy of P0.1 measurements performed by ICU ventilators: a bench study. Beloncle F; Piquilloud L; Olivier PY; Vuillermoz A; Yvin E; Mercat A; Richard JC Ann Intensive Care; 2019 Sep; 9(1):104. PubMed ID: 31520230 [TBL] [Abstract][Full Text] [Related]
63. Home versus intensive care pressure support devices. Experimental and clinical comparison. Lofaso F; Brochard L; Hang T; Lorino H; Harf A; Isabey D Am J Respir Crit Care Med; 1996 May; 153(5):1591-9. PubMed ID: 8630607 [TBL] [Abstract][Full Text] [Related]
64. Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study. Wallon G; Bonnet A; Guérin C Br J Anaesth; 2013 Jun; 110(6):1045-51. PubMed ID: 23381721 [TBL] [Abstract][Full Text] [Related]
65. Heliox delivery with noninvasive positive pressure ventilation: a laboratory study. Chatmongkolchart S; Kacmarek RM; Hess DR Respir Care; 2001 Mar; 46(3):248-54. PubMed ID: 11262551 [TBL] [Abstract][Full Text] [Related]
66. FLOW-i ventilator performance in the presence of a circle system leak. Lucangelo U; Ajčević M; Accardo A; Borelli M; Peratoner A; Comuzzi L; Zin WA J Clin Monit Comput; 2017 Apr; 31(2):273-280. PubMed ID: 27062381 [TBL] [Abstract][Full Text] [Related]
67. Anesthesia and critical care ventilator modes: past, present, and future. Bristle TJ; Collins S; Hewer I; Hollifield K AANA J; 2014 Oct; 82(5):387-400. PubMed ID: 25842654 [TBL] [Abstract][Full Text] [Related]
68. Correction of error in respiratory resistance measurements made with the flow-interruption technique during mechanical ventilation: evaluation of the puritan bennett 7200 and 840 ventilators. Lit LM; Doelken P; Mayo PH Respir Care; 2004 Sep; 49(9):1022-8. PubMed ID: 15329173 [TBL] [Abstract][Full Text] [Related]
69. Volume ventilation of infants with congenital heart disease: a comparison of Dräger, NAD 6000 and Siemens, Servo 900C ventilators. Stayer SA; Andropoulos DB; Bent ST; McKenzie ED; Fraser CD Anesth Analg; 2001 Jan; 92(1):76-9. PubMed ID: 11133604 [TBL] [Abstract][Full Text] [Related]
70. Imposed work and oxygen delivery during spontaneous breathing with adult disposable manual ventilators. Hess D; Hirsch C; Marquis-D'Amico C; Kacmarek RM Anesthesiology; 1994 Nov; 81(5):1256-63. PubMed ID: 7978485 [TBL] [Abstract][Full Text] [Related]
71. Laboratory and clinical evaluation of the MAX transport ventilator. Johannigman JA; Branson RD; Campbell R; Hurst JM Respir Care; 1990 Oct; 35(10):952-9. PubMed ID: 10145333 [TBL] [Abstract][Full Text] [Related]
72. Novel High-tech, Low-cost Ventilation for Military Use, Mass Casualty Incidents, Stockpiling, and Underserved Communities. Weeks MK; Widmann NJ; Nickel AJ; McDonough JM; Mason M; Zuckerberg J; Forti RM; Kilbaugh TJ Mil Med; 2024 Aug; 189(Suppl 3):823-831. PubMed ID: 39160872 [TBL] [Abstract][Full Text] [Related]
73. [Effect on inspiratory cycling-off synchronization with different expiratory trigger sensitivity level during pressure-support ventilation: a lung model study]. Chen Y; Zhang X; Cheng K; Zhou X Zhonghua Yi Xue Za Zhi; 2014 Oct; 94(38):2977-81. PubMed ID: 25547698 [TBL] [Abstract][Full Text] [Related]
74. Performance of ventilators for noninvasive positive-pressure ventilation in children. Fauroux B; Leroux K; Desmarais G; Isabey D; Clément A; Lofaso F; Louis B Eur Respir J; 2008 Jun; 31(6):1300-7. PubMed ID: 18321932 [TBL] [Abstract][Full Text] [Related]
75. The response of flow-triggered infant ventilators. Nishimura M; Hess D; Kacmarek RM Am J Respir Crit Care Med; 1995 Dec; 152(6 Pt 1):1901-9. PubMed ID: 8520753 [TBL] [Abstract][Full Text] [Related]
76. [Effects of aerosol inhalation on respiratory mechanical parameters under different ventilation patterns and ventilator parameters]. Wang L; Guan C; Qin X; Qu Y Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2018 Nov; 30(11):1036-1040. PubMed ID: 30541641 [TBL] [Abstract][Full Text] [Related]
77. Influence of dynamic leaks in volume-targeted pressure support noninvasive ventilation: a bench study. Luján M; Sogo A; Grimau C; Pomares X; Blanch L; Monsó E Respir Care; 2015 Feb; 60(2):191-200. PubMed ID: 25316889 [TBL] [Abstract][Full Text] [Related]
78. [A study of pneumatic performances of 2 new anesthesia ventilators: a trial]. Rawal R; Beydon L Ann Fr Anesth Reanim; 1996; 15(7):1107-10. PubMed ID: 9180989 [TBL] [Abstract][Full Text] [Related]
79. Inspiratory oscillatory flow with a portable ventilator: a bench study. Frank GE; Trimmel H; Fitzgerald RD Crit Care; 2005 Aug; 9(4):R315-22. PubMed ID: 16137343 [TBL] [Abstract][Full Text] [Related]
80. Pressures available for transtracheal jet ventilation from anesthesia machines and wall-mounted oxygen flowmeters. Fassl J; Jenny U; Nikiforov S; Murray WB; Foster PA Anesth Analg; 2010 Jan; 110(1):94-100. PubMed ID: 19910614 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]