These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 17067406)

  • 1. A method for increasing jet nebulizer delivery efficiency for aerosol drug delivery in ventilated newborns: an in vitro study.
    Quong MC; Thébaud B; Finlay WH
    Respir Care; 2006 Nov; 51(11):1244-50. PubMed ID: 17067406
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation.
    Ari A; Atalay OT; Harwood R; Sheard MM; Aljamhan EA; Fink JB
    Respir Care; 2010 Jul; 55(7):845-51. PubMed ID: 20587095
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Albuterol delivery from a metered-dose inhaler with spacer is reduced following short-duration manual ventilation in a neonatal ventilator-lung model.
    Lugo RA; Ballard J
    Respir Care; 2004 Sep; 49(9):1029-34. PubMed ID: 15329174
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A survey of albuterol administration practices in intubated patients in the neonatal intensive care unit.
    Ballard J; Lugo RA; Salyer JW
    Respir Care; 2002 Jan; 47(1):31-8. PubMed ID: 11749685
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of aerosol generator devices at 3 locations in humidified and non-humidified circuits during adult mechanical ventilation.
    Ari A; Areabi H; Fink JB
    Respir Care; 2010 Jul; 55(7):837-44. PubMed ID: 20587094
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Albuterol Delivery Efficiency in a Pediatric Model of Noninvasive Ventilation With Double-Limb Circuit.
    Velasco J; Berlinski A
    Respir Care; 2018 Feb; 63(2):141-146. PubMed ID: 29114011
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Albuterol delivery during noninvasive ventilation.
    Branconnier MP; Hess DR
    Respir Care; 2005 Dec; 50(12):1649-53. PubMed ID: 16318646
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pressurized Metered-Dose Inhalers Versus Nebulizers in the Treatment of Mechanically Ventilated Subjects With Artificial Airways: An In Vitro Study.
    Ari A; Harwood RJ; Sheard MM; Fink JB
    Respir Care; 2015 Nov; 60(11):1570-4. PubMed ID: 26152470
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of a prototype expiratory-phase aerosol controller during simulated pediatric volume-controlled ventilation.
    Keenan J; Salyer JW
    Respir Care; 1994 Jun; 39(6):617-22. PubMed ID: 10146016
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aerosol deposition in neonatal ventilation.
    Dubus JC; Vecellio L; De Monte M; Fink JB; Grimbert D; Montharu J; Valat C; Behan N; Diot P
    Pediatr Res; 2005 Jul; 58(1):10-4. PubMed ID: 15774850
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aerosol production and aerosol droplet size distribution during mechanical ventilation (IPPV) with a new ultrasonic nebulizer.
    Kemming GI; Kreyling W; Habler O; Merkel M; Kleen M; Welte M; Messmer K; Zwissler B
    Eur J Med Res; 1996 Apr; 1(7):321-7. PubMed ID: 9364032
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pulmonary Drug Delivery System for inhalation therapy in mechanically ventilated patients.
    Dhand R; Sohal H
    Expert Rev Med Devices; 2008 Jan; 5(1):9-18. PubMed ID: 18095891
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ventilator-integrated jet nebulization systems: tidal volume control and efficiency of synchronization.
    Ehrmann S; Lyazidi A; Louis B; Isabey D; Le Pennec D; Brochard L; Apiou-Sbirlea G
    Respir Care; 2014 Oct; 59(10):1508-16. PubMed ID: 24917450
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Delivery of a nebulized aerosol to a lung model during mechanical ventilation. Effect of ventilator settings and nebulizer type, position, and volume of fill.
    O'Doherty MJ; Thomas SH; Page CJ; Treacher DF; Nunan TO
    Am Rev Respir Dis; 1992 Aug; 146(2):383-8. PubMed ID: 1489128
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vitro comparison of five nebulizers during noninvasive ventilation: analysis of inhaled and lost doses.
    Michotte JB; Jossen E; Roeseler J; Liistro G; Reychler G
    J Aerosol Med Pulm Drug Deliv; 2014 Dec; 27(6):430-40. PubMed ID: 24517084
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of inspiratory flow pattern and nebulizer position on aerosol delivery with a vibrating-mesh nebulizer during invasive mechanical ventilation: an in vitro analysis.
    Dugernier J; Wittebole X; Roeseler J; Michotte JB; Sottiaux T; Dugernier T; Laterre PF; Reychler G
    J Aerosol Med Pulm Drug Deliv; 2015 Jun; 28(3):229-36. PubMed ID: 25393556
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of exhalation valve and nebulizer position on albuterol delivery during noninvasive positive pressure ventilation.
    Dai B; Kang J; Sun LF; Tan W; Zhao HW
    J Aerosol Med Pulm Drug Deliv; 2014 Apr; 27(2):125-32. PubMed ID: 23668546
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Albuterol delivery by 4 different nebulizers placed in 4 different positions in a pediatric ventilator in vitro model.
    Berlinski A; Willis JR
    Respir Care; 2013 Jul; 58(7):1124-33. PubMed ID: 23107173
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Albuterol Delivery Efficiency in a Pediatric Model of Noninvasive Ventilation With a Single-Limb Circuit.
    Berlinski A; Velasco J
    Respir Care; 2019 Nov; 64(11):1366-1370. PubMed ID: 31113855
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Albuterol delivery via tracheostomy tube.
    Piccuito CM; Hess DR
    Respir Care; 2005 Aug; 50(8):1071-6. PubMed ID: 16225712
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.