BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

330 related articles for article (PubMed ID: 17073863)

  • 1. Pressure-controlled ventilation is superior to volume-controlled ventilation with a laryngeal mask airway in children.
    Bordes M; Semjen F; Degryse C; Bourgain JL; Cros AM
    Acta Anaesthesiol Scand; 2007 Jan; 51(1):82-5. PubMed ID: 17073863
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of three modes of positive pressure mask ventilation during induction of anaesthesia: a prospective, randomized, crossover study.
    Seet MM; Soliman KM; Sbeih ZF
    Eur J Anaesthesiol; 2009 Nov; 26(11):913-6. PubMed ID: 19390448
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Positive pressure ventilation with the size 5 laryngeal mask.
    Brimacombe JR
    J Clin Anesth; 1997 Mar; 9(2):113-7. PubMed ID: 9075035
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pressure versus volume-controlled ventilation with a laryngeal mask airway in paediatric patients.
    Keidan I; Berkenstadt H; Segal E; Perel A
    Paediatr Anaesth; 2001 Nov; 11(6):691-4. PubMed ID: 11696145
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Gastric insufflation pressure, air leakage and respiratory mechanics in the use of the laryngeal mask airway (LMA) in children.
    Wahlen BM; Heinrichs W; Latorre F
    Paediatr Anaesth; 2004 Apr; 14(4):313-7. PubMed ID: 15078376
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The effects of endotracheal suction on gas exchange and respiratory mechanics in mechanically ventilated patients under pressure-controlled or volume-controlled ventilation].
    Liu XW; Liu Z
    Zhonghua Jie He He Hu Xi Za Zhi; 2007 Oct; 30(10):751-5. PubMed ID: 18218205
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Gas leak and gastric insufflation during controlled ventilation: face mask versus laryngeal mask airway.
    Ho-Tai LM; Devitt JH; Noel AG; O'Donnell MP
    Can J Anaesth; 1998 Mar; 45(3):206-11. PubMed ID: 9579256
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Facemask pressure-controlled ventilation in children: what is the pressure limit?
    Lagarde S; Semjen F; Nouette-Gaulain K; Masson F; Bordes M; Meymat Y; Cros AM
    Anesth Analg; 2010 Jun; 110(6):1676-9. PubMed ID: 20435941
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pressure-controlled versus volume-controlled ventilation during one-lung ventilation for thoracic surgery.
    Unzueta MC; Casas JI; Moral MV
    Anesth Analg; 2007 May; 104(5):1029-33, tables of contents. PubMed ID: 17456648
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of laryngeal mask airway (LMA)- Proseal and the LMA-Classic in ventilated children receiving neuromuscular blockade.
    Lardner DR; Cox RG; Ewen A; Dickinson D
    Can J Anaesth; 2008 Jan; 55(1):29-35. PubMed ID: 18166745
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pressure vs. volume control ventilation: effects on gastric insufflation with size-1 LMA.
    Sinha A; Sharma B; Sood J
    Paediatr Anaesth; 2010 Dec; 20(12):1111-7. PubMed ID: 21199120
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Carbon dioxide clearance in rabbits during expiratory phase intratracheal pulmonary ventilation.
    Meyappan RT; Raszynski A; Bohorquez J; Totapally BR; Koul PB; Norozian FM; Valcourt K; Torbati D
    ASAIO J; 2007; 53(2):163-7. PubMed ID: 17413555
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A randomized crossover comparison between the Laryngeal Mask Airway-Uniqueâ„¢ and the air-Q intubating laryngeal airway in children.
    Jagannathan N; Sohn LE; Mankoo R; Langen KE; Mandler T
    Paediatr Anaesth; 2012 Feb; 22(2):161-7. PubMed ID: 21917058
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prospective, randomized comparison of laryngeal tube and laryngeal mask airway in pediatric patients.
    Genzwuerker HV; Fritz A; Hinkelbein J; Finteis T; Schlaefer A; Schaeffer M; Thil E; Rapp HJ
    Paediatr Anaesth; 2006 Dec; 16(12):1251-6. PubMed ID: 17121555
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Lower cuff pressures improve the seal of pediatric laryngeal mask airways.
    Licina A; Chambers NA; Hullett B; Erb TO; von Ungern-Sternberg BS
    Paediatr Anaesth; 2008 Oct; 18(10):952-6. PubMed ID: 18647269
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cricoid pressure impedes insertion of, and ventilation through, the ProSeal laryngeal mask airway in anesthetized, paralyzed patients.
    Li CW; Xue FS; Xu YC; Liu Y; Mao P; Liu KP; Yang QY; Zhang GH; Sun HT
    Anesth Analg; 2007 May; 104(5):1195-8, tables of contents. PubMed ID: 17456674
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reduced air leakage by adjusting the cuff pressure in pediatric laryngeal mask airways during spontaneous ventilation.
    Hockings L; Heaney M; Chambers NA; Erb TO; von Ungern-Sternberg BS
    Paediatr Anaesth; 2010 Apr; 20(4):313-7. PubMed ID: 20470334
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pressure-controlled versus volume-controlled ventilation: does it matter?
    Campbell RS; Davis BR
    Respir Care; 2002 Apr; 47(4):416-24; discussion 424-6. PubMed ID: 11929615
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A prospective, randomized comparison of cobra perilaryngeal airway and laryngeal mask airway unique in pediatric patients.
    Szmuk P; Ghelber O; Matuszczak M; Rabb MF; Ezri T; Sessler DI
    Anesth Analg; 2008 Nov; 107(5):1523-30. PubMed ID: 18931209
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.