These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 17075701)

  • 21. Effects of phase duration and pulse rate on loudness and pitch percepts in the first auditory midbrain implant patients: Comparison to cochlear implant and auditory brainstem implant results.
    Lim HH; Lenarz T; Joseph G; Battmer RD; Patrick JF; Lenarz M
    Neuroscience; 2008 Jun; 154(1):370-80. PubMed ID: 18384971
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Investigation of a new electrode array technology for a central auditory prosthesis.
    Calixto R; Salamat B; Rode T; Hartmann T; Volckaerts B; Ruther P; Lenarz T; Lim HH
    PLoS One; 2013; 8(12):e82148. PubMed ID: 24312638
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Temporal properties of chronic cochlear electrical stimulation determine temporal resolution of neurons in cat inferior colliculus.
    Vollmer M; Snyder RL; Leake PA; Beitel RE; Moore CM; Rebscher SJ
    J Neurophysiol; 1999 Dec; 82(6):2883-902. PubMed ID: 10601427
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Descending and tonotopic projection patterns from the auditory cortex to the inferior colliculus.
    Straka MM; Hughes R; Lee P; Lim HH
    Neuroscience; 2015 Aug; 300():325-37. PubMed ID: 26002315
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Responses of neurons in the feline inferior colliculus to modulated electrical stimuli applied on and within the ventral cochlear nucleus; Implications for an advanced auditory brainstem implant.
    McCreery D; Yadev K; Han M
    Hear Res; 2018 Jun; 363():85-97. PubMed ID: 29573880
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Auditory midbrain implant: histomorphologic effects of long-term implantation and electric stimulation of a new deep brain stimulation array.
    Lenarz M; Lim HH; Lenarz T; Reich U; Marquardt N; Klingberg MN; Paasche G; Reuter G; Stan AC
    Otol Neurotol; 2007 Dec; 28(8):1045-52. PubMed ID: 18043431
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Auditory brainstem stimulation with a conformable microfabricated array elicits responses with tonotopically organized components.
    Guex AA; Hight AE; Narasimhan S; Vachicouras N; Lee DJ; Lacour SP; Brown MC
    Hear Res; 2019 Jun; 377():339-352. PubMed ID: 30867111
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Acute cochlear nucleus compression alters tuning properties of inferior colliculus neurons.
    Crea KN; Shivdasani MN; Argent RE; Mauger SJ; Rathbone GD; O'Leary SJ; Paolini AG
    Audiol Neurootol; 2010; 15(1):18-26. PubMed ID: 19451706
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Intralaminar stimulation of the inferior colliculus facilitates frequency-specific activation in the auditory cortex.
    Allitt BJ; Benjaminsen C; Morgan SJ; Paolini AG
    J Neural Eng; 2013 Aug; 10(4):046008. PubMed ID: 23800787
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Plasticity in central representations in the inferior colliculus induced by chronic single- vs. two-channel electrical stimulation by a cochlear implant after neonatal deafness.
    Leake PA; Snyder RL; Rebscher SJ; Moore CM; Vollmer M
    Hear Res; 2000 Sep; 147(1-2):221-41. PubMed ID: 10962187
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effects of Electrical Stimulation in the Inferior Colliculus on Frequency Discrimination by Rhesus Monkeys and Implications for the Auditory Midbrain Implant.
    Pages DS; Ross DA; Puñal VM; Agashe S; Dweck I; Mueller J; Grill WM; Wilson BS; Groh JM
    J Neurosci; 2016 May; 36(18):5071-83. PubMed ID: 27147659
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Degradation of temporal resolution in the auditory midbrain after prolonged deafness is reversed by electrical stimulation of the cochlea.
    Vollmer M; Leake PA; Beitel RE; Rebscher SJ; Snyder RL
    J Neurophysiol; 2005 Jun; 93(6):3339-55. PubMed ID: 15659529
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Plasticity of tonotopic maps in humans: influence of hearing loss, hearing aids and cochlear implants.
    Thai-Van H; Veuillet E; Norena A; Guiraud J; Collet L
    Acta Otolaryngol; 2010 Mar; 130(3):333-7. PubMed ID: 19845491
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Bilateral Changes of Spontaneous Activity Within the Central Auditory Pathway Upon Chronic Unilateral Intracochlear Electrical Stimulation.
    Basta D; Götze R; Gröschel M; Jansen S; Janke O; Tzschentke B; Boyle P; Ernst A
    Otol Neurotol; 2015 Dec; 36(10):1759-65. PubMed ID: 26571409
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Cortical responses to cochlear implant stimulation: channel interactions.
    Bierer JA; Middlebrooks JC
    J Assoc Res Otolaryngol; 2004 Mar; 5(1):32-48. PubMed ID: 14564662
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Auditory brainstem implant in neurofibromatosis type 2 and non-neurofibromatosis type 2 patients.
    Grayeli AB; Kalamarides M; Bouccara D; Ambert-Dahan E; Sterkers O
    Otol Neurotol; 2008 Dec; 29(8):1140-6. PubMed ID: 18849886
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Processing of speech temporal and spectral information by users of auditory brainstem implants and cochlear implants.
    Azadpour M; McKay CM
    Ear Hear; 2014; 35(5):e192-203. PubMed ID: 25010634
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Auditory brainstem implants in NF2 patients: results and review of the literature.
    Sanna M; Di Lella F; Guida M; Merkus P
    Otol Neurotol; 2012 Feb; 33(2):154-64. PubMed ID: 22246383
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Spatial selectivity to intracochlear electrical stimulation in the inferior colliculus is degraded after long-term deafness in cats.
    Vollmer M; Beitel RE; Snyder RL; Leake PA
    J Neurophysiol; 2007 Nov; 98(5):2588-603. PubMed ID: 17855592
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Auditory Brainstem Implantation for Adults With Neurofibromatosis 2 or Severe Inner Ear Abnormalities: A Health Technology Assessment.
    Ontario Health (Quality)
    Ont Health Technol Assess Ser; 2020; 20(4):1-85. PubMed ID: 32190165
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.