BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

687 related articles for article (PubMed ID: 17078959)

  • 1. Modification of poly(dimethylsiloxane) microfluidic channels with silica nanoparticles based on layer-by-layer assembly technique.
    Wang W; Zhao L; Zhang JR; Wang XM; Zhu JJ; Chen HY
    J Chromatogr A; 2006 Dec; 1136(1):111-7. PubMed ID: 17078959
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Surface modification with BSA blocking based on in situ synthesized gold nanoparticles in poly(dimethylsiloxane) microchip.
    Fan DH; Yuan SW; Shen YM
    Colloids Surf B Biointerfaces; 2010 Feb; 75(2):608-11. PubMed ID: 19896345
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Controlling electroosmotic flow in poly(dimethylsiloxane) separation channels by means of prepolymer additives.
    Luo Y; Huang B; Wu H; Zare RN
    Anal Chem; 2006 Jul; 78(13):4588-92. PubMed ID: 16808469
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Proteins modification of poly(dimethylsiloxane) microfluidic channels for the enhanced microchip electrophoresis.
    Wang AJ; Xu JJ; Chen HY
    J Chromatogr A; 2006 Feb; 1107(1-2):257-64. PubMed ID: 16387312
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Generation of hydrophilic poly(dimethylsiloxane) for high-performance microchip electrophoresis.
    Vickers JA; Caulum MM; Henry CS
    Anal Chem; 2006 Nov; 78(21):7446-52. PubMed ID: 17073411
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electroosmotic flow-switchable poly(dimethylsiloxane) microfluidic channel modified with cysteine based on gold nanoparticles.
    Wang W; Zhao L; Zhou F; Zhu JJ; Zhang JR
    Talanta; 2007 Sep; 73(3):534-9. PubMed ID: 19073067
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multilayer poly(vinyl alcohol)-adsorbed coating on poly(dimethylsiloxane) microfluidic chips for biopolymer separation.
    Wu D; Luo Y; Zhou X; Dai Z; Lin B
    Electrophoresis; 2005 Jan; 26(1):211-8. PubMed ID: 15624173
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Self-assembled epoxy-modified polymer coating on a poly(dimethylsiloxane) microchip for EOF inhibition and biopolymers separation.
    Wu D; Qin J; Lin B
    Lab Chip; 2007 Nov; 7(11):1490-6. PubMed ID: 17960276
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microchip CE analysis of amino acids on a titanium dioxide nanoparticles-coated PDMS microfluidic device with in-channel indirect amperometric detection.
    Qiu JD; Wang L; Liang RP; Wang JW
    Electrophoresis; 2009 Oct; 30(19):3472-9. PubMed ID: 19757433
    [TBL] [Abstract][Full Text] [Related]  

  • 10. PDMS microchip coated with polydopamine/gold nanoparticles hybrid for efficient electrophoresis separation of amino acids.
    Liang RP; Meng XY; Liu CM; Qiu JD
    Electrophoresis; 2011 Nov; 32(23):3331-40. PubMed ID: 22134977
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surface modification of poly(dimethylsiloxane) microfluidic devices and its application in simultaneous analysis of uric acid and ascorbic acid in human urine.
    Liang RP; Gan GH; Qiu JD
    J Sep Sci; 2008 Aug; 31(15):2860-7. PubMed ID: 18655017
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultraviolet sealing and poly(dimethylacrylamide) modification for poly(dimethylsiloxane)/glass microchips.
    Chen L; Ren J; Bi R; Chen D
    Electrophoresis; 2004 Mar; 25(6):914-21. PubMed ID: 15004855
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bioactive heparin immobilized onto microfluidic channels in poly(dimethylsiloxane) results in hydrophilic surface properties.
    Thorslund S; Sanchez J; Larsson R; Nikolajeff F; Bergquist J
    Colloids Surf B Biointerfaces; 2005 Dec; 46(4):240-7. PubMed ID: 16352425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Electroosmotic flow in poly(dimethylsiloxane) microchannels.
    Bao N; Xu JJ; Zhang Q; Hang JL; Chen HY
    J Chromatogr A; 2005 Dec; 1099(1-2):203-6. PubMed ID: 16303131
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Capillary zone electrophoresis of amino acids on a hybrid poly(dimethylsiloxane)-glass chip.
    Mourzina Y; Steffen A; Kalyagin D; Carius R; Offenhäusser A
    Electrophoresis; 2005 May; 26(9):1849-60. PubMed ID: 15719361
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Grafting epoxy-modified hydrophilic polymers onto poly(dimethylsiloxane) microfluidic chip to resist nonspecific protein adsorption.
    Wu D; Zhao B; Dai Z; Qin J; Lin B
    Lab Chip; 2006 Jul; 6(7):942-7. PubMed ID: 16804600
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electroosmotic flow in a poly(dimethylsiloxane) channel does not depend on percent curing agent.
    Wheeler AR; Trapp G; Trapp O; Zare RN
    Electrophoresis; 2004 Apr; 25(7-8):1120-4. PubMed ID: 15095455
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sol-gel modified poly(dimethylsiloxane) microfluidic devices with high electroosmotic mobilities and hydrophilic channel wall characteristics.
    Roman GT; Hlaus T; Bass KJ; Seelhammer TG; Culbertson CT
    Anal Chem; 2005 Mar; 77(5):1414-22. PubMed ID: 15732926
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hydrophilic biopolymer grafted on poly(dimethylsiloxane) surface for microchip electrophoresis.
    Feng JJ; Wang AJ; Fan J; Xu JJ; Chen HY
    Anal Chim Acta; 2010 Jan; 658(1):75-80. PubMed ID: 20082777
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrochromatographic separation on a poly(dimethylsiloxane)/glass chip by integration of a capillary containing an acrylate monolithic stationary phase.
    Blas M; Delaunay N; Rocca JL
    J Sep Sci; 2007 Nov; 30(17):3043-9. PubMed ID: 17924367
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 35.