These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
272 related articles for article (PubMed ID: 17089834)
1. Energy and integrated dose dependence of MOSFET dosimeter sensitivity for irradiation energies between 30 kV and 60Co. Lavallée MC; Gingras L; Beaulieu L Med Phys; 2006 Oct; 33(10):3683-9. PubMed ID: 17089834 [TBL] [Abstract][Full Text] [Related]
2. Response of an implantable MOSFET dosimeter to 192Ir HDR radiation. Fagerstrom JM; Micka JA; DeWerd LA Med Phys; 2008 Dec; 35(12):5729-37. PubMed ID: 19175130 [TBL] [Abstract][Full Text] [Related]
3. Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code. Panettieri V; Duch MA; Jornet N; Ginjaume M; Carrasco P; Badal A; Ortega X; Ribas M Phys Med Biol; 2007 Jan; 52(1):303-16. PubMed ID: 17183143 [TBL] [Abstract][Full Text] [Related]
4. Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams. Jornet N; Carrasco P; Jurado D; Ruiz A; Eudaldo T; Ribas M Med Phys; 2004 Sep; 31(9):2534-42. PubMed ID: 15487735 [TBL] [Abstract][Full Text] [Related]
5. Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV. Ehringfeld C; Schmid S; Poljanc K; Kirisits C; Aiginger H; Georg D Phys Med Biol; 2005 Jan; 50(2):289-303. PubMed ID: 15742945 [TBL] [Abstract][Full Text] [Related]
6. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV). Tedgren AC; Hedman A; Grindborg JE; Carlsson GA Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372 [TBL] [Abstract][Full Text] [Related]
7. Characterization of a cable-free system based on p-type MOSFET detectors for "in vivo" entrance skin dose measurements in interventional radiology. Falco MD; D'Andrea M; Strigari L; D'Alessio D; Quagliani F; Santoni R; Bosco AL Med Phys; 2012 Aug; 39(8):4866-74. PubMed ID: 22894413 [TBL] [Abstract][Full Text] [Related]
8. Characterization of responses and comparison of calibration factor for commercial MOSFET detectors. Bharanidharan G; Manigandan D; Devan K; Subramani V; Gopishankar N; Ganesh T; Joshi R; Rath G; Velmurugan J; Aruna P; Ganesan S Med Dosim; 2005; 30(4):213-8. PubMed ID: 16275563 [TBL] [Abstract][Full Text] [Related]
9. MOSFET dosimetry with high spatial resolution in intense synchrotron-generated x-ray microbeams. Siegbahn EA; Bräuer-Krisch E; Bravin A; Nettelbeck H; Lerch ML; Rosenfeld AB Med Phys; 2009 Apr; 36(4):1128-37. PubMed ID: 19472618 [TBL] [Abstract][Full Text] [Related]
10. Monte Carlo calculations of the ionization chamber wall correction factors for 192Ir and 60Co gamma rays and 250 kV x-rays for use in calibration of 192Ir HDR brachytherapy sources. Ferreira IH; de Almeida CE; Marre D; Marechal MH; Bridier A; Chavaudra J Phys Med Biol; 1999 Aug; 44(8):1897-904. PubMed ID: 10473203 [TBL] [Abstract][Full Text] [Related]
11. Verification of the plan dosimetry for high dose rate brachytherapy using metal-oxide-semiconductor field effect transistor detectors. Qi ZY; Deng XW; Huang SM; Lu J; Lerch M; Cutajar D; Rosenfeld A Med Phys; 2007 Jun; 34(6):2007-13. PubMed ID: 17654904 [TBL] [Abstract][Full Text] [Related]
12. Comparison of angular free-in-air and tissue-equivalent phantom response measurements in p-MOSFET dosimeters. Pomije BD; Huh CH; Tressler MA; Hintenlang DE; Bolch WE Health Phys; 2001 May; 80(5):497-505. PubMed ID: 11316081 [TBL] [Abstract][Full Text] [Related]
13. An in-house developed resettable MOSFET dosimeter for radiotherapy. Verellen D; Van Vaerenbergh S; Tournel K; Heuninckx K; Joris L; Duchateau M; Linthout N; Gevaert T; Reynders T; Van de Vondel I; Coppens L; Depuydt T; De Ridder M; Storme G Phys Med Biol; 2010 Feb; 55(4):N97-109. PubMed ID: 20090184 [TBL] [Abstract][Full Text] [Related]
14. Characteristics and performance of a micro-MOSFET: an "imageable" dosimeter for image-guided radiotherapy. Rowbottoma CG; Jaffray DA Med Phys; 2004 Mar; 31(3):609-15. PubMed ID: 15070261 [TBL] [Abstract][Full Text] [Related]
15. In vivo dosimetry with MOSFETs: dosimetric characterization and first clinical results in intraoperative radiotherapy. Consorti R; Petrucci A; Fortunato F; Soriani A; Marzi S; Iaccarino G; Landoni V; Benassi M Int J Radiat Oncol Biol Phys; 2005 Nov; 63(3):952-60. PubMed ID: 16199324 [TBL] [Abstract][Full Text] [Related]
16. Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams. Manigandan D; Bharanidharan G; Aruna P; Devan K; Elangovan D; Patil V; Tamilarasan R; Vasanthan S; Ganesan S Phys Med; 2009 Sep; 25(3):141-7. PubMed ID: 19128995 [TBL] [Abstract][Full Text] [Related]
17. Performance characteristics of a microMOSFET as an in vivo dosimeter in radiation therapy. Ramaseshan R; Kohli KS; Zhang TJ; Lam T; Norlinger B; Hallil A; Islam M Phys Med Biol; 2004 Sep; 49(17):4031-48. PubMed ID: 15470921 [TBL] [Abstract][Full Text] [Related]
18. MOSFET detectors in quality assurance of tomotherapy treatments. Cherpak A; Studinski RC; Cygler JE Radiother Oncol; 2008 Feb; 86(2):242-50. PubMed ID: 18037519 [TBL] [Abstract][Full Text] [Related]
19. Characterization of a new MOSFET detector configuration for in vivo skin dosimetry. Scalchi P; Francescon P; Rajaguru P Med Phys; 2005 Jun; 32(6):1571-8. PubMed ID: 16013716 [TBL] [Abstract][Full Text] [Related]
20. Dosimetric evaluation of a MOSFET detector for clinical application in photon therapy. Kohno R; Hirano E; Nishio T; Miyagishi T; Goka T; Kawashima M; Ogino T Radiol Phys Technol; 2008 Jan; 1(1):55-61. PubMed ID: 20821164 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]