757 related articles for article (PubMed ID: 17089835)
21. Design and implementation of a water phantom for IMRT, arc therapy, and tomotherapy dose distribution measurements. Pallotta S; Marrazzo L; Bucciolini M Med Phys; 2007 Oct; 34(10):3724-31. PubMed ID: 17985617 [TBL] [Abstract][Full Text] [Related]
22. EBT GAFCHROMIC(TM) film dosimetry in compensator-based intensity modulated radiation therapy. Vaezzadeh S; Allahverdi M; Nedaie HA; Ay M; Shirazi A; Yarahmadi M Med Dosim; 2013; 38(2):176-83. PubMed ID: 23290715 [TBL] [Abstract][Full Text] [Related]
23. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry. Chetty IJ; Charland PM Phys Med Biol; 2002 Oct; 47(20):3629-41. PubMed ID: 12433124 [TBL] [Abstract][Full Text] [Related]
24. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. Zhu XR; Jursinic PA; Grimm DF; Lopez F; Rownd JJ; Gillin MT Med Phys; 2002 Aug; 29(8):1687-92. PubMed ID: 12201414 [TBL] [Abstract][Full Text] [Related]
25. Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning. Fragoso M; Wen N; Kumar S; Liu D; Ryu S; Movsas B; Munther A; Chetty IJ Phys Med Biol; 2010 Aug; 55(16):4445-64. PubMed ID: 20668343 [TBL] [Abstract][Full Text] [Related]
26. Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: a comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations. Martens C; Reynaert N; De Wagter C; Nilsson P; Coghe M; Palmans H; Thierens H; De Neve W Med Phys; 2002 Jul; 29(7):1528-35. PubMed ID: 12148735 [TBL] [Abstract][Full Text] [Related]
27. Normalized sensitometric curves for the verification of hybrid IMRT treatment plans with multiple energies. Georg D; Kroupa B; Winkler P; Pötter R Med Phys; 2003 Jun; 30(6):1142-50. PubMed ID: 12852539 [TBL] [Abstract][Full Text] [Related]
28. A system for intensity modulated dose plan verification based on an experimental pencil beam kernel obtained by deconvolution. Azcona JD; Burguete J Med Phys; 2008 Jan; 35(1):248-59. PubMed ID: 18293580 [TBL] [Abstract][Full Text] [Related]
29. Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons. Charland PM; Chetty IJ; Yokoyama S; Fraass BA J Appl Clin Med Phys; 2003; 4(1):25-39. PubMed ID: 12540816 [TBL] [Abstract][Full Text] [Related]
30. Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code. Francescon P; Cora S; Chiovati P Med Phys; 2003 Feb; 30(2):144-57. PubMed ID: 12607832 [TBL] [Abstract][Full Text] [Related]
31. Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams. Sánchez-Doblado F; Andreo P; Capote R; Leal A; Perucha M; Arráns R; Núñez L; Mainegra E; Lagares JI; Carrasco E Phys Med Biol; 2003 Jul; 48(14):2081-99. PubMed ID: 12894972 [TBL] [Abstract][Full Text] [Related]
33. Three-dimensional dose verification for intensity modulated radiation therapy using optical CT based polymer gel dosimetry. Wuu CS; Xu Y Med Phys; 2006 May; 33(5):1412-9. PubMed ID: 16752577 [TBL] [Abstract][Full Text] [Related]
34. Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams. Greer PB; Vial P; Oliver L; Baldock C Med Phys; 2007 Nov; 34(11):4389-98. PubMed ID: 18072504 [TBL] [Abstract][Full Text] [Related]
35. Monte Carlo simulations of dose near a nonradioactive gold seed. Chow JC; Grigorov GN Med Phys; 2006 Dec; 33(12):4614-21. PubMed ID: 17278814 [TBL] [Abstract][Full Text] [Related]
36. Experimental measurements and Monte Carlo simulations for dosimetric evaluations of intrafraction motion for gated and ungated intensity modulated arc therapy deliveries. Oliver M; Gladwish A; Staruch R; Craig J; Gaede S; Chen J; Wong E Phys Med Biol; 2008 Nov; 53(22):6419-36. PubMed ID: 18941277 [TBL] [Abstract][Full Text] [Related]
37. Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries. Chakarova R; Gustafsson M; Bäck A; Drugge N; Palm Å; Lindberg A; Berglund M Radiother Oncol; 2012 Jan; 102(1):102-7. PubMed ID: 21741719 [TBL] [Abstract][Full Text] [Related]
38. Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy. Schembri V; Heijmen BJ Med Phys; 2007 Jun; 34(6):2113-8. PubMed ID: 17654914 [TBL] [Abstract][Full Text] [Related]
39. The response of Kodak EDR2 film in high-energy electron beams. Gerbi BJ; Dimitroyannis DA Med Phys; 2003 Oct; 30(10):2703-5. PubMed ID: 14596308 [TBL] [Abstract][Full Text] [Related]
40. Comparison of dose calculation algorithms in slab phantoms with cortical bone equivalent heterogeneities. Carrasco P; Jornet N; Duch MA; Panettieri V; Weber L; Eudaldo T; Ginjaume M; Ribas M Med Phys; 2007 Aug; 34(8):3323-33. PubMed ID: 17879796 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]