These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

757 related articles for article (PubMed ID: 17089835)

  • 21. Design and implementation of a water phantom for IMRT, arc therapy, and tomotherapy dose distribution measurements.
    Pallotta S; Marrazzo L; Bucciolini M
    Med Phys; 2007 Oct; 34(10):3724-31. PubMed ID: 17985617
    [TBL] [Abstract][Full Text] [Related]  

  • 22. EBT GAFCHROMIC(TM) film dosimetry in compensator-based intensity modulated radiation therapy.
    Vaezzadeh S; Allahverdi M; Nedaie HA; Ay M; Shirazi A; Yarahmadi M
    Med Dosim; 2013; 38(2):176-83. PubMed ID: 23290715
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry.
    Chetty IJ; Charland PM
    Phys Med Biol; 2002 Oct; 47(20):3629-41. PubMed ID: 12433124
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator.
    Zhu XR; Jursinic PA; Grimm DF; Lopez F; Rownd JJ; Gillin MT
    Med Phys; 2002 Aug; 29(8):1687-92. PubMed ID: 12201414
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Dosimetric verification and clinical evaluation of a new commercially available Monte Carlo-based dose algorithm for application in stereotactic body radiation therapy (SBRT) treatment planning.
    Fragoso M; Wen N; Kumar S; Liu D; Ryu S; Movsas B; Munther A; Chetty IJ
    Phys Med Biol; 2010 Aug; 55(16):4445-64. PubMed ID: 20668343
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: a comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations.
    Martens C; Reynaert N; De Wagter C; Nilsson P; Coghe M; Palmans H; Thierens H; De Neve W
    Med Phys; 2002 Jul; 29(7):1528-35. PubMed ID: 12148735
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Normalized sensitometric curves for the verification of hybrid IMRT treatment plans with multiple energies.
    Georg D; Kroupa B; Winkler P; Pötter R
    Med Phys; 2003 Jun; 30(6):1142-50. PubMed ID: 12852539
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A system for intensity modulated dose plan verification based on an experimental pencil beam kernel obtained by deconvolution.
    Azcona JD; Burguete J
    Med Phys; 2008 Jan; 35(1):248-59. PubMed ID: 18293580
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons.
    Charland PM; Chetty IJ; Yokoyama S; Fraass BA
    J Appl Clin Med Phys; 2003; 4(1):25-39. PubMed ID: 12540816
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code.
    Francescon P; Cora S; Chiovati P
    Med Phys; 2003 Feb; 30(2):144-57. PubMed ID: 12607832
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.
    Sánchez-Doblado F; Andreo P; Capote R; Leal A; Perucha M; Arráns R; Núñez L; Mainegra E; Lagares JI; Carrasco E
    Phys Med Biol; 2003 Jul; 48(14):2081-99. PubMed ID: 12894972
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Microionization chamber for reference dosimetry in IMRT verification: clinical implications on OAR dosimetric errors.
    Sánchez-Doblado F; Capote R; Leal A; Roselló JV; Lagares JI; Arráns R; Hartmann GH
    Phys Med Biol; 2005 Mar; 50(5):959-70. PubMed ID: 15798268
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Three-dimensional dose verification for intensity modulated radiation therapy using optical CT based polymer gel dosimetry.
    Wuu CS; Xu Y
    Med Phys; 2006 May; 33(5):1412-9. PubMed ID: 16752577
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams.
    Greer PB; Vial P; Oliver L; Baldock C
    Med Phys; 2007 Nov; 34(11):4389-98. PubMed ID: 18072504
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Monte Carlo simulations of dose near a nonradioactive gold seed.
    Chow JC; Grigorov GN
    Med Phys; 2006 Dec; 33(12):4614-21. PubMed ID: 17278814
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Experimental measurements and Monte Carlo simulations for dosimetric evaluations of intrafraction motion for gated and ungated intensity modulated arc therapy deliveries.
    Oliver M; Gladwish A; Staruch R; Craig J; Gaede S; Chen J; Wong E
    Phys Med Biol; 2008 Nov; 53(22):6419-36. PubMed ID: 18941277
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Superficial dose distribution in breast for tangential radiation treatment, Monte Carlo evaluation of Eclipse algorithms in case of phantom and patient geometries.
    Chakarova R; Gustafsson M; Bäck A; Drugge N; Palm Å; Lindberg A; Berglund M
    Radiother Oncol; 2012 Jan; 102(1):102-7. PubMed ID: 21741719
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy.
    Schembri V; Heijmen BJ
    Med Phys; 2007 Jun; 34(6):2113-8. PubMed ID: 17654914
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The response of Kodak EDR2 film in high-energy electron beams.
    Gerbi BJ; Dimitroyannis DA
    Med Phys; 2003 Oct; 30(10):2703-5. PubMed ID: 14596308
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of dose calculation algorithms in slab phantoms with cortical bone equivalent heterogeneities.
    Carrasco P; Jornet N; Duch MA; Panettieri V; Weber L; Eudaldo T; Ginjaume M; Ribas M
    Med Phys; 2007 Aug; 34(8):3323-33. PubMed ID: 17879796
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 38.