BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

567 related articles for article (PubMed ID: 17090006)

  • 1. Top-down ESI-ECD-FT-ICR mass spectrometry localizes noncovalent protein-ligand binding sites.
    Xie Y; Zhang J; Yin S; Loo JA
    J Am Chem Soc; 2006 Nov; 128(45):14432-3. PubMed ID: 17090006
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Studying noncovalent protein complexes by electrospray ionization mass spectrometry.
    Loo JA
    Mass Spectrom Rev; 1997; 16(1):1-23. PubMed ID: 9414489
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteins.
    Beck JL; Colgrave ML; Ralph SF; Sheil MM
    Mass Spectrom Rev; 2001; 20(2):61-87. PubMed ID: 11455562
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of droplet size, capillary-cone distance and selected instrumental parameters for the analysis of noncovalent protein-ligand complexes by nano-electrospray ionization mass spectrometry.
    Benkestock K; Sundqvist G; Edlund PO; Roeraade J
    J Mass Spectrom; 2004 Sep; 39(9):1059-67. PubMed ID: 15386746
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Gas-phase binding of non-covalent protein complexes between bovine pancreatic trypsin inhibitor and its target enzymes studied by electrospray ionization tandem mass spectrometry.
    Nesatyy VJ
    J Mass Spectrom; 2001 Aug; 36(8):950-9. PubMed ID: 11523096
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mapping a noncovalent protein-peptide interface by top-down FTICR mass spectrometry using electron capture dissociation.
    Clarke DJ; Murray E; Hupp T; Mackay CL; Langridge-Smith PR
    J Am Soc Mass Spectrom; 2011 Aug; 22(8):1432-40. PubMed ID: 21953198
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ligand-metal ion binding to proteins: investigation by ESI mass spectrometry.
    Potier N; Rogniaux H; Chevreux G; Van Dorsselaer A
    Methods Enzymol; 2005; 402():361-89. PubMed ID: 16401515
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of dissociation constants of inhibitors binding to Src SH2 domain protein by non-covalent electrospray ionization mass spectrometry.
    Bligh SW; Haley T; Lowe PN
    J Mol Recognit; 2003; 16(3):139-48. PubMed ID: 12833569
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mass spectrometry detection and characterization of noncovalent protein complexes.
    Yin S; Loo JA
    Methods Mol Biol; 2009; 492():273-82. PubMed ID: 19241039
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Consecutive ion activation for top down mass spectrometry: improved protein sequencing by nozzle-skimmer dissociation.
    Zhai H; Han X; Breuker K; McLafferty FW
    Anal Chem; 2005 Sep; 77(18):5777-84. PubMed ID: 16159106
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pulsed hydrogen/deuterium exchange MS/MS for studying the relationship between noncovalent protein complexes in solution and in the gas phase after electrospray ionization.
    Hossain BM; Konermann L
    Anal Chem; 2006 Mar; 78(5):1613-9. PubMed ID: 16503614
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reactive-electrospray-assisted laser desorption/ionization for characterization of peptides and proteins.
    Peng IX; Ogorzalek Loo RR; Shiea J; Loo JA
    Anal Chem; 2008 Sep; 80(18):6995-7003. PubMed ID: 18683952
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detection and localization of protein modifications by high resolution tandem mass spectrometry.
    Meng F; Forbes AJ; Miller LM; Kelleher NL
    Mass Spectrom Rev; 2005; 24(2):126-34. PubMed ID: 15389861
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The role of electron capture dissociation in biomolecular analysis.
    Cooper HJ; HÃ¥kansson K; Marshall AG
    Mass Spectrom Rev; 2005; 24(2):201-22. PubMed ID: 15389856
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrospray ionization mass spectrometry: a promising new technique in the study of protein/DNA noncovalent complexes.
    Veenstra TD
    Biochem Biophys Res Commun; 1999 Apr; 257(1):1-5. PubMed ID: 10092500
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Binding constant determination of high-affinity protein-ligand complexes by electrospray ionization mass spectrometry and ligand competition.
    Wortmann A; Jecklin MC; Touboul D; Badertscher M; Zenobi R
    J Mass Spectrom; 2008 May; 43(5):600-8. PubMed ID: 18074334
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Method for distinguishing specific from nonspecific protein-ligand complexes in nanoelectrospray ionization mass spectrometry.
    Sun J; Kitova EN; Wang W; Klassen JS
    Anal Chem; 2006 May; 78(9):3010-8. PubMed ID: 16642987
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 'Top down' protein characterization via tandem mass spectrometry.
    Reid GE; McLuckey SA
    J Mass Spectrom; 2002 Jul; 37(7):663-75. PubMed ID: 12124999
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hydrogen/deuterium exchange mass spectrometry with top-down electron capture dissociation for characterizing structural transitions of a 17 kDa protein.
    Pan J; Han J; Borchers CH; Konermann L
    J Am Chem Soc; 2009 Sep; 131(35):12801-8. PubMed ID: 19670873
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fourier-transform mass spectrometry for automated fragmentation and identification of 5-20 kDa proteins in mixtures.
    Johnson JR; Meng F; Forbes AJ; Cargile BJ; Kelleher NL
    Electrophoresis; 2002 Sep; 23(18):3217-23. PubMed ID: 12298093
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.