These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 17090433)

  • 1. Microbiological quality assurance of purified water by ozonization of storage and distribution system.
    Florjanic M; Kristl J
    Drug Dev Ind Pharm; 2006; 32(10):1113-21. PubMed ID: 17090433
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of pipe materials and VBNC cells on culturable bacteria in a chlorinated drinking water model system.
    Lee DG; Park SJ; Kim SJ
    J Microbiol Biotechnol; 2007 Sep; 17(9):1558-62. PubMed ID: 18062238
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The control of biofilm formation by hydrodynamics of purified water in industrial distribution system.
    Florjanič M; Kristl J
    Int J Pharm; 2011 Feb; 405(1-2):16-22. PubMed ID: 21129467
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of microbial quality of household water output from desalination systems by the heterotrophic plate count method.
    Yari AR; Mohammadi MJ; Geravandi S; Doosti Z; Matboo SA; Jang SA; Nazari S
    J Water Health; 2018 Dec; 16(6):930-937. PubMed ID: 30540267
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Tracking the concentration of heterotrophic plate count bacteria from the source to the consumer's tap.
    Pepper IL; Rusin P; Quintanar DR; Haney C; Josephson KL; Gerba CP
    Int J Food Microbiol; 2004 May; 92(3):289-95. PubMed ID: 15145587
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Understanding the distribution system as a bioreactor: a framework for managing heterotrophic plate count levels.
    Huck PM; Gagnon GA
    Int J Food Microbiol; 2004 May; 92(3):347-53. PubMed ID: 15145593
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Resistance of Legionella to disinfection in hot water distribution systems.
    Saby S; Vidal A; Suty H
    Water Sci Technol; 2005; 52(8):15-28. PubMed ID: 16312947
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Establishment of HPC(R2A) for regrowth control in non-chlorinated distribution systems.
    Uhl W; Schaule G
    Int J Food Microbiol; 2004 May; 92(3):317-25. PubMed ID: 15145590
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Control of bacterial contamination in microfiltered water dispensers (MWDs) by disinfection.
    Zanetti F; De Luca G; Sacchetti R
    Int J Food Microbiol; 2009 Jan; 128(3):446-52. PubMed ID: 19017550
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Applicability of solid-phase cytometry and epifluorescence microscopy for rapid assessment of the microbiological quality of dialysis water.
    Riepl M; Schauer S; Knetsch S; Holzhammer E; Farnleitner AH; Sommer R; Kirschner AK
    Nephrol Dial Transplant; 2011 Nov; 26(11):3640-5. PubMed ID: 21948860
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Water and air ozone treatment as an alternative sanitizing technology.
    Martinelli M; Giovannangeli F; Rotunno S; Trombetta CM; Montomoli E
    J Prev Med Hyg; 2017 Mar; 58(1):E48-E52. PubMed ID: 28515631
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Microbiological contamination of drinking water in a commercial household water filter system.
    Daschner FD; Rüden H; Simon R; Clotten J
    Eur J Clin Microbiol Infect Dis; 1996 Mar; 15(3):233-7. PubMed ID: 8740859
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Factors affecting bacterial growth in drinking water distribution system.
    Lu W; Zhang XJ
    Biomed Environ Sci; 2005 Apr; 18(2):137-40. PubMed ID: 16001834
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monitoring of dialysis water systems--is there a need for increased sampling?
    James R
    EDTNA ERCA J; 2006; 32(2):74-7. PubMed ID: 16898097
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Disinfectant efficacy of chlorite and chlorine dioxide in drinking water biofilms.
    Gagnon GA; Rand JL; O'leary KC; Rygel AC; Chauret C; Andrews RC
    Water Res; 2005 May; 39(9):1809-17. PubMed ID: 15899279
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Modeling of heterotrophic bacteria counts in a water distribution system.
    Francisque A; Rodriguez MJ; Miranda-Moreno LF; Sadiq R; Proulx F
    Water Res; 2009 Mar; 43(4):1075-87. PubMed ID: 19070348
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of phosphate-enhanced ozone/biofiltration on formation of disinfection byproducts and occurrence of opportunistic pathogens in drinking water distribution systems.
    Xing X; Wang H; Hu C; Liu L
    Water Res; 2018 Aug; 139():168-176. PubMed ID: 29635153
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of an automated dental unit water system's contamination control protocol.
    Puttaiah R; Svoboda KK; Lin SM; Montebugnoli L; Dolci G; Spratt D; Siebert J
    J Contemp Dent Pract; 2012 Jan; 13(1):1-10. PubMed ID: 22430686
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of cavitation on chemical disinfection efficiency.
    Jyoti KK; Pandit AB
    Water Res; 2004 May; 38(9):2248-57. PubMed ID: 15142785
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Identification of bacteria in drinking and purified water during the monitoring of a typical water purification system.
    Penna VT; Martins SA; Mazzola PG
    BMC Public Health; 2002 Aug; 2():13. PubMed ID: 12182763
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.