150 related articles for article (PubMed ID: 17097535)
1. Prediction and discrimination of osteoporotic hip fracture in postmenopausal women.
Durosier C; Hans D; Krieg MA; Schott AM
J Clin Densitom; 2006; 9(4):475-95. PubMed ID: 17097535
[TBL] [Abstract][Full Text] [Related]
2. Assessment of a new quantitative ultrasound calcaneus measurement: precision and discrimination of hip fractures in elderly women compared with dual X-ray absorptiometry.
He YQ; Fan B; Hans D; Li J; Wu CY; Njeh CF; Zhao S; Lu Y; Tsuda-Futami E; Fuerst T; Genant HK
Osteoporos Int; 2000; 11(4):354-60. PubMed ID: 10928226
[TBL] [Abstract][Full Text] [Related]
3. Do markers of bone resorption add to bone mineral density and ultrasonographic heel measurement for the prediction of hip fracture in elderly women? The EPIDOS prospective study.
Garnero P; Dargent-Molina P; Hans D; Schott AM; Bréart G; Meunier PJ; Delmas PD
Osteoporos Int; 1998; 8(6):563-9. PubMed ID: 10326062
[TBL] [Abstract][Full Text] [Related]
4. Device-specific weighted T-score for two quantitative ultrasounds: operational propositions for the management of osteoporosis for 65 years and older women in Switzerland.
Hans D; Hartl F; Krieg MA
Osteoporos Int; 2003 May; 14(3):251-8. PubMed ID: 12730788
[TBL] [Abstract][Full Text] [Related]
5. Discriminatory ability of quantitative ultrasound measurements is similar to dual-energy X-ray absorptiometry in a Brazilian women population with osteoporotic fracture.
Pinheiro MM; Castro CH; Frisoli A; Szejnfeld VL
Calcif Tissue Int; 2003 Dec; 73(6):555-64. PubMed ID: 14517710
[TBL] [Abstract][Full Text] [Related]
6. Is time since hip fracture influencing the discrimination between fractured and nonfractured subjects as assessed at the calcaneum by three technologically different quantitative ultrasound devices?
Hans D; Allaoua S; Genton L; Delmi M; Vuagnat H; Rizzoli R; Tahintzi-Zawadynski S; Perron C; Pichard C; Slosman DO
Calcif Tissue Int; 2002 Dec; 71(6):485-92. PubMed ID: 12232682
[TBL] [Abstract][Full Text] [Related]
7. Does the combination of quantitative ultrasound and dual-energy X-ray absorptiometry improve fracture discrimination?
Frost ML; Blake GM; Fogelman I
Osteoporos Int; 2001; 12(6):471-7. PubMed ID: 11446563
[TBL] [Abstract][Full Text] [Related]
8. [Bone mineral density in postmenopausal women with proximal femoral fractures--comparative study between quantitative ultrasonometry and gold standard DXA].
Schnabel M; Eser G; Ziller V; Mann D; Mann E; Hadji P
Zentralbl Chir; 2005 Oct; 130(5):469-75. PubMed ID: 16220445
[TBL] [Abstract][Full Text] [Related]
9. Quantitative ultrasound or clinical risk factors--which best identifies women at risk of osteoporosis?
Stewart A; Reid DM
Br J Radiol; 2000 Feb; 73(866):165-71. PubMed ID: 10884730
[TBL] [Abstract][Full Text] [Related]
10. Use of clinical risk factors in elderly women with low bone mineral density to identify women at higher risk of hip fracture: The EPIDOS prospective study.
Dargent-Molina P; Douchin MN; Cormier C; Meunier PJ; Bréart G;
Osteoporos Int; 2002 Jul; 13(7):593-9. PubMed ID: 12111021
[TBL] [Abstract][Full Text] [Related]
11. Association between low-frequency ultrasound and hip fractures -- comparison with DXA-based BMD.
Määttä M; Moilanen P; Timonen J; Pulkkinen P; Korpelainen R; Jämsä T
BMC Musculoskelet Disord; 2014 Jun; 15():208. PubMed ID: 24934318
[TBL] [Abstract][Full Text] [Related]
12. Ultrasound measurements at the proximal phalanges in healthy women and patients with hip fractures.
Alenfeld FE; Wüster C; Funck C; Pereira-Lima JF; Fritz T; Meeder PJ; Ziegler R
Osteoporos Int; 1998; 8(5):393-8. PubMed ID: 9850344
[TBL] [Abstract][Full Text] [Related]
13. Fracture risk prediction using BMD and clinical risk factors in early postmenopausal women: sensitivity of the WHO FRAX tool.
Trémollieres FA; Pouillès JM; Drewniak N; Laparra J; Ribot CA; Dargent-Molina P
J Bone Miner Res; 2010 May; 25(5):1002-9. PubMed ID: 20200927
[TBL] [Abstract][Full Text] [Related]
14. Predictive value of BMD for hip and other fractures.
Johnell O; Kanis JA; Oden A; Johansson H; De Laet C; Delmas P; Eisman JA; Fujiwara S; Kroger H; Mellstrom D; Meunier PJ; Melton LJ; O'Neill T; Pols H; Reeve J; Silman A; Tenenhouse A
J Bone Miner Res; 2005 Jul; 20(7):1185-94. PubMed ID: 15940371
[TBL] [Abstract][Full Text] [Related]
15. A comparison of fracture discrimination using calcaneal quantitative ultrasound and dual X-ray absorptiometry in women with a history of fracture at sites other than the spine and hip.
Frost ML; Blake GM; Fogelman I
Calcif Tissue Int; 2002 Sep; 71(3):207-11. PubMed ID: 12154392
[TBL] [Abstract][Full Text] [Related]
16. Health-economic comparison of three recommended drugs for the treatment of osteoporosis.
Brecht JG; Kruse HP; Möhrke W; Oestreich A; Huppertz E
Int J Clin Pharmacol Res; 2004; 24(1):1-10. PubMed ID: 15575171
[TBL] [Abstract][Full Text] [Related]
17. Primary care use of FRAX: absolute fracture risk assessment in postmenopausal women and older men.
Siris ES; Baim S; Nattiv A
Postgrad Med; 2010 Jan; 122(1):82-90. PubMed ID: 20107292
[TBL] [Abstract][Full Text] [Related]
18. Low bone mineral density and fracture burden in postmenopausal women.
Cranney A; Jamal SA; Tsang JF; Josse RG; Leslie WD
CMAJ; 2007 Sep; 177(6):575-80. PubMed ID: 17846439
[TBL] [Abstract][Full Text] [Related]
19. Low metacarpal index predicts hip fracture: a prospective population study of 3,561 subjects with 15 years of follow-up.
Haara M; Heliövaara M; Impivaara O; Arokoski JP; Manninen P; Knekt P; Kärkkäinen A; Reunanen A; Aromaa A; Kröger H
Acta Orthop; 2006 Feb; 77(1):9-14. PubMed ID: 16534696
[TBL] [Abstract][Full Text] [Related]
20. Does follow-up duration influence the ultrasound and DXA prediction of hip fracture? The EPIDOS prospective study.
Hans D; Schott AM; Duboeuf F; Durosier C; Meunier PJ;
Bone; 2004 Aug; 35(2):357-63. PubMed ID: 15268884
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]