  • 1. Myopotentials leading to ventricular fibrillation detection after advisory defibrillator generator replacement.
    Eckart RE; Hruczkowski TW; Stevenson WG; Epstein LM
    Pacing Clin Electrophysiol; 2006 Nov; 29(11):1273-6. PubMed ID: 17100683
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms.
    Kowalski M; Ellenbogen KA; Wood MA; Friedman PL
    Europace; 2008 Aug; 10(8):914-7. PubMed ID: 18565976
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Undersensing of ventricular fibrillation due to interference between a pacemaker and defibrillator in the same patient.
    Van Casteren L; Huybrechts W; Willems R
    Europace; 2009 Oct; 11(10):1390-1. PubMed ID: 19654130
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ventricular oversensing after replacement of an implantable cardioverter-defibrillator.
    Arias MA; Puchol A; Castellanos E; Pachón M; Rodríguez-Padial L
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):925-7. PubMed ID: 19572871
    [No Abstract]   [Full Text] [Related]  

  • 5. An algorithm to predict implantable cardioverter-defibrillator lead failure.
    Gunderson BD; Patel AS; Bounds CA; Shepard RK; Wood MA; Ellenbogen KA
    J Am Coll Cardiol; 2004 Nov; 44(9):1898-902. PubMed ID: 15519026
    [TBL] [Abstract][Full Text] [Related]  

  • 6. T-wave oversensing by an implantable cardioverter defibrillator after successful ablation of idiopathic ventricular fibrillation.
    Strohmer B; Schernthaner C; Pichler M
    Pacing Clin Electrophysiol; 2006 Apr; 29(4):431-5. PubMed ID: 16650276
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The "Pain wave": P‑wave oversensing in subcutaneous ICD.
    Kattih B; Duncker D; König T; Hohmann S; Oswald H; Veltmann C
    Herzschrittmacherther Elektrophysiol; 2016 Jun; 27(2):151-3. PubMed ID: 27084342
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrocautery-induced ventricular fibrillation during routine implantable cardioverter-defibrillator generator replacement.
    Cassagneau R; Hanninen M; Yee R
    Europace; 2014 Mar; 16(3):319. PubMed ID: 24068449
    [No Abstract]   [Full Text] [Related]  

  • 9. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years.
    Kleemann T; Becker T; Doenges K; Vater M; Senges J; Schneider S; Saggau W; Weisse U; Seidl K
    Circulation; 2007 May; 115(19):2474-80. PubMed ID: 17470696
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Early automatic remote detection of combined lead insulation defect and ICD damage.
    Neuzil P; Taborsky M; Holy F; Wallbrueck K
    Europace; 2008 May; 10(5):556-7. PubMed ID: 18227352
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Resolution of T-wave oversensing with implantable cardioverter defibrillator generator replacement in an adolescent.
    Tuzcu V
    Pacing Clin Electrophysiol; 2007 Jul; 30(7):929-32. PubMed ID: 17584279
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Left ventricular mechanical assist devices and cardiac device interactions: an observational case series.
    Foo D; Walker BD; Kuchar DL; Thorburn CW; Tay A; Hayward CS; Macdonald P; Keogh A; Kotlyar E; Spratt P; Jansz P
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):879-87. PubMed ID: 19572863
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inhibition of bradycardia pacing and detection of ventricular fibrillation due to far-field atrial sensing in a triple chamber implantable cardioverter defibrillator.
    Vollmann D; Lüthje L; Görtler G; Unterberg C
    Pacing Clin Electrophysiol; 2002 Oct; 25(10):1513-6. PubMed ID: 12418750
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multiple high lead impedances in an implantable-cardioverter defibrillator system: what is the mechanism?
    Ho RT
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1173-5. PubMed ID: 23594162
    [No Abstract]   [Full Text] [Related]  

  • 16. Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Stadler RW; Gillberg JM; Patel AS; Ellenbogen KA
    Circulation; 2008 Nov; 118(21):2122-9. PubMed ID: 18981299
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Near-fatal incident on routine induction of ventricular fibrillation at the replacement of an implantable cardioverter defibrillator.
    Kolb C; Zrenner B; Schmitt C
    Int J Cardiol; 2006 Oct; 112(3):e74-5. PubMed ID: 16859778
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of implantable defibrillator longevity under clinical circumstances: implications for device selection.
    Knops P; Theuns DA; Res JC; Jordaens L
    Pacing Clin Electrophysiol; 2009 Oct; 32(10):1276-85. PubMed ID: 19796344
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).
    Day JD; Doshi RN; Belott P; Birgersdotter-Green U; Behboodikhah M; Ott P; Glatter KA; Tobias S; Frumin H; Lee BK; Merillat J; Wiener I; Wang S; Grogin H; Chun S; Patrawalla R; Crandall B; Osborn JS; Weiss JP; Lappe DL; Neuman S
    Circulation; 2007 May; 115(18):2382-9. PubMed ID: 17470697
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Non-determinable defibrillation threshold and inefficacy of implantable cardioverter/defibrillator shocks due to defective connections of the defibrillator lead terminals in the device header port.
    Maagh P; Trappe HJ; Meissner A
    Europace; 2007 Dec; 9(12):1161-2. PubMed ID: 17913694
    [TBL] [Abstract][Full Text] [Related]  