These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 17102841)

  • 1. Ultrasonic enhancement of bead-based bioaffinity assays.
    Wiklund M; Hertz HM
    Lab Chip; 2006 Oct; 6(10):1279-92. PubMed ID: 17102841
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Acoustofluidics 21: ultrasound-enhanced immunoassays and particle sensors.
    Wiklund M; Radel S; Hawkes JJ
    Lab Chip; 2013 Jan; 13(1):25-39. PubMed ID: 23138938
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rotavirus detection using ultrasound enhanced latex agglutination and turbidimetry.
    Sobanski MA; Ellis RW; Hastings JG
    J Immunoassay; 2000 Nov; 21(4):315-25. PubMed ID: 11071250
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Amplification of fluorescence with packed beads to enhance the sensitivity of miniaturized detection in microfluidic chip.
    Shin KS; Lee SW; Han KC; Kim SK; Yang EK; Park JH; Ju BK; Kang JY; Kim TS
    Biosens Bioelectron; 2007 Apr; 22(9-10):2261-7. PubMed ID: 17169549
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rapid detection of Mycoplasma pneumonia in a microfluidic device using immunoagglutination assay and static light scattering.
    Kim K; Jung HS; Song JY; Lee MR; Kim KS; Suh KY
    Electrophoresis; 2009 Sep; 30(18):3206-11. PubMed ID: 19722211
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid, femtomolar bioassays in complex matrices combining microfluidics and magnetoelectronics.
    Mulvaney SP; Cole CL; Kniller MD; Malito M; Tamanaha CR; Rife JC; Stanton MW; Whitman LJ
    Biosens Bioelectron; 2007 Sep; 23(2):191-200. PubMed ID: 17532619
    [TBL] [Abstract][Full Text] [Related]  

  • 7. On-chip immuno-agglutination assay with analyte capture by dynamic manipulation of superparamagnetic beads.
    Moser Y; Lehnert T; Gijs MA
    Lab Chip; 2009 Nov; 9(22):3261-7. PubMed ID: 19865734
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities.
    Choi JW; Oh KW; Thomas JH; Heineman WR; Halsall HB; Nevin JH; Helmicki AJ; Henderson HT; Ahn CH
    Lab Chip; 2002 Feb; 2(1):27-30. PubMed ID: 15100857
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Active bead-linked immunoassay on protein microarrays.
    Morozov VN; Morozova TY
    Anal Chim Acta; 2006 Mar; 564(1):40-52. PubMed ID: 17723360
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rapid analysis of alpha-fetoprotein by chemiluminescence microfluidic immunoassay system based on super-paramagnetic microbeads.
    Huang H; Zheng XL; Zheng JS; Pan J; Pu XY
    Biomed Microdevices; 2009 Feb; 11(1):213-6. PubMed ID: 18923903
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasonic standing wave manipulation technology integrated into a dielectrophoretic chip.
    Wiklund M; Günther C; Lemor R; Jäger M; Fuhr G; Hertz HM
    Lab Chip; 2006 Dec; 6(12):1537-44. PubMed ID: 17203158
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Applications of ultrasound streaming and radiation force in biosensors.
    Kuznetsova LA; Coakley WT
    Biosens Bioelectron; 2007 Mar; 22(8):1567-77. PubMed ID: 16979887
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bead-based immunoassays using a micro-chip flow cytometer.
    Holmes D; She JK; Roach PL; Morgan H
    Lab Chip; 2007 Aug; 7(8):1048-56. PubMed ID: 17653348
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasonic enhancement of coated particle agglutination immunoassays: influence of particle density and compressibility.
    Thomas NE; Sobanski MA; Coakley WT
    Ultrasound Med Biol; 1999 Mar; 25(3):443-50. PubMed ID: 10374987
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Using highly carboxylated microspheres to simplify immunoassays and enhance diffusional mixing in a microfluidic device.
    Lucas LJ; Han JH; Yoon JY
    Colloids Surf B Biointerfaces; 2006 May; 49(2):106-11. PubMed ID: 16621472
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bead-based microfluidic immunoassays: the next generation.
    Lim CT; Zhang Y
    Biosens Bioelectron; 2007 Feb; 22(7):1197-204. PubMed ID: 16857357
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diagnostic particle agglutination using ultrasound: a new technology to rejuvenate old microbiological methods.
    Ellis RW; Sobanski MA
    J Med Microbiol; 2000 Oct; 49(10):853-859. PubMed ID: 11023182
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rapid microfluidic separation of magnetic beads through dielectrophoresis and magnetophoresis.
    Krishnan JN; Kim C; Park HJ; Kang JY; Kim TS; Kim SK
    Electrophoresis; 2009 May; 30(9):1457-63. PubMed ID: 19425001
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultrasensitive protein detection: a case for microfluidic magnetic bead-based assays.
    Tekin HC; Gijs MA
    Lab Chip; 2013 Dec; 13(24):4711-39. PubMed ID: 24145920
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Direct manipulation and observation of the rotational motion of single optically trapped microparticles and biological cells in microvortices.
    Shelby JP; Mutch SA; Chiu DT
    Anal Chem; 2004 May; 76(9):2492-7. PubMed ID: 15117188
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.