These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 17106638)

  • 1. Modeling, design and validation of a novel microfluidic sensor for in-vitro isotonic measurement of microvessel contraction/dilation.
    Izzo I; Dario P
    Biomed Microdevices; 2007 Feb; 9(1):69-81. PubMed ID: 17106638
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A microfluidic manipulator for enrichment and alignment of moving cells and particles.
    Chen HH; Sun B; Tran KK; Shen H; Gao D
    J Biomech Eng; 2009 Jul; 131(7):074505. PubMed ID: 19640141
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite element modeling of a microparticle manipulator.
    Neild A; Oberti S; Haake A; Dual J
    Ultrasonics; 2006 Dec; 44 Suppl 1():e455-60. PubMed ID: 16797643
    [TBL] [Abstract][Full Text] [Related]  

  • 4. "Microfluidic drifting"--implementing three-dimensional hydrodynamic focusing with a single-layer planar microfluidic device.
    Mao X; Waldeisen JR; Huang TJ
    Lab Chip; 2007 Oct; 7(10):1260-2. PubMed ID: 17896008
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Photonic crystal-based all-optical on-chip sensor.
    Liu Y; Salemink HW
    Opt Express; 2012 Aug; 20(18):19912-20. PubMed ID: 23037043
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV system.
    Lima R; Wada S; Tanaka S; Takeda M; Ishikawa T; Tsubota K; Imai Y; Yamaguchi T
    Biomed Microdevices; 2008 Apr; 10(2):153-67. PubMed ID: 17885805
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design and dynamic evaluation for a linear ultrasonic stage using the thin-disc structure actuator.
    Wen F; Yen CY
    Ultrasonics; 2007 Dec; 47(1-4):23-31. PubMed ID: 17692880
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Novel liquid flow sensor based on differential pressure method.
    Liu Z; Hong T; Zhang W; Li Z; Chen H
    Rev Sci Instrum; 2007 Jan; 78(1):015108. PubMed ID: 17503947
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fundamental mechanics of aortic heart valve closure.
    Hose DR; Narracott AJ; Penrose JM; Baguley D; Jones IP; Lawford PV
    J Biomech; 2006; 39(5):958-67. PubMed ID: 16488234
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomimetic design of microfluidic manifolds based on a generalised Murray's law.
    Emerson DR; Cieślicki K; Gu X; Barber RW
    Lab Chip; 2006 Mar; 6(3):447-54. PubMed ID: 16511629
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hydrodynamic focusing investigation in a micro-flow cytometer.
    Yang AS; Hsieh WH
    Biomed Microdevices; 2007 Apr; 9(2):113-22. PubMed ID: 17151936
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simulation and experimentation of a microfluidic device based on electrowetting on dielectric.
    Jang LS; Lin GH; Lin YL; Hsu CY; Kan WH; Chen CH
    Biomed Microdevices; 2007 Dec; 9(6):777-86. PubMed ID: 17520369
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Diffusive spreading of time-dependent pressures in elastic microfluidic devices.
    Wunderlich BK; Klessinger UA; Bausch AR
    Lab Chip; 2010 Apr; 10(8):1025-9. PubMed ID: 20358110
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Micro flow sensor based on two closely spaced amperometric sensors.
    Wu J; Ye J
    Lab Chip; 2005 Dec; 5(12):1344-7. PubMed ID: 16286963
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Soft microflow sensors.
    Attia R; Pregibon DC; Doyle PS; Viovy JL; Bartolo D
    Lab Chip; 2009 May; 9(9):1213-8. PubMed ID: 19370239
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High performance microfluidic capillary electrophoresis devices.
    Fu LM; Leong JC; Lin CF; Tai CH; Tsai CH
    Biomed Microdevices; 2007 Jun; 9(3):405-12. PubMed ID: 17487587
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A method for dynamic system characterization using hydraulic series resistance.
    Kim D; Chesler NC; Beebe DJ
    Lab Chip; 2006 May; 6(5):639-44. PubMed ID: 16652179
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantitative characterization of magnetic separators: comparison of systems with and without integrated microfluidic mixers.
    Lund-Olesen T; Bruus H; Hansen MF
    Biomed Microdevices; 2007 Apr; 9(2):195-205. PubMed ID: 17165127
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modelling, fabrication and characterization of a polymeric micromixer based on sequential segmentation.
    Nguyen NT; Huang X
    Biomed Microdevices; 2006 Jun; 8(2):133-9. PubMed ID: 16688572
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hydrodynamically tunable optofluidic cylindrical microlens.
    Mao X; Waldeisen JR; Juluri BK; Huang TJ
    Lab Chip; 2007 Oct; 7(10):1303-8. PubMed ID: 17896014
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.