These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 17117766)

  • 1. Development of the mennen 3 peripro fixation plate for the treatment of periprosthetic fractures of the femur.
    Pappas CA; Young PG; Lee AJ
    Proc Inst Mech Eng H; 2006 Oct; 220(7):775-85. PubMed ID: 17117766
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Controlled plastic deformation for the fastening mechanism of an internal fixation device. The new Mennen 3 PeriPro plate.
    Pappas CA; Young PG; Lee AJ
    Comput Methods Biomech Biomed Engin; 2007 Apr; 10(2):111-20. PubMed ID: 18651277
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position.
    Dubov A; Kim SY; Shah S; Schemitsch EH; Zdero R; Bougherara H
    Proc Inst Mech Eng H; 2011 Sep; 225(9):857-65. PubMed ID: 22070023
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Mennen femoral plate for fixation of periprosthetic femoral fractures following hip arthroplasty.
    Ahuja S; Chatterji S
    Injury; 2002 Jan; 33(1):47-50. PubMed ID: 11879832
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mennen plate in hip and shoulder joint replacement.
    Kligman M; Othrimski I; Roffman M
    Bull Hosp Jt Dis; 1997; 56(2):84-7. PubMed ID: 9220096
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The biomechanical effect of bone quality and fracture topography on locking plate fixation in periprosthetic femoral fractures.
    Leonidou A; Moazen M; Lepetsos P; Graham SM; Macheras GA; Tsiridis E
    Injury; 2015 Feb; 46(2):213-7. PubMed ID: 25467710
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures.
    Floyd JC; O'Toole RV; Stall A; Forward DP; Nabili M; Shillingburg D; Hsieh A; Nascone JW
    J Orthop Trauma; 2009 Oct; 23(9):628-33. PubMed ID: 19897983
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Finite-element modelling of femoral shaft fracture fixation techniques post total hip arthroplasty.
    Mihalko WM; Beaudoin AJ; Cardea JA; Krause WR
    J Biomech; 1992 May; 25(5):469-76. PubMed ID: 1592852
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A biomechanical study comparing cortical onlay allograft struts and plates in the treatment of periprosthetic femoral fractures.
    Wilson D; Frei H; Masri BA; Oxland TR; Duncan CP
    Clin Biomech (Bristol); 2005 Jan; 20(1):70-6. PubMed ID: 15567539
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new, low cost, locking plate for the long-term fixation of a critical size bone defect in the ratfemur: in vivo performance, biomechanical and finite element analysis.
    Mataliotakis GI; Tsouknidas A; Panteliou S; Vekris MD; Mitsionis GI; Agathopoulos S; Beris AE
    Biomed Mater Eng; 2015; 25(4):335-46. PubMed ID: 26407196
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical evaluation of periprosthetic refractures following distal femur locking plate fixation.
    Alexander J; Morris RP; Kaimrajh D; Milne E; Latta L; Flink A; Lindsey RW
    Injury; 2015 Dec; 46(12):2368-73. PubMed ID: 26553428
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A short plate compression screw with diagonal bolts--a biomechanical evaluation performed experimentally and by numerical computation.
    Peleg E; Mosheiff R; Liebergall M; Mattan Y
    Clin Biomech (Bristol); 2006 Nov; 21(9):963-8. PubMed ID: 16893595
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Treatment of periprosthetic femur fractures around a well-fixed hip arthroplasty implant: span the whole bone.
    Moloney GB; Westrick ER; Siska PA; Tarkin IS
    Arch Orthop Trauma Surg; 2014 Jan; 134(1):9-14. PubMed ID: 24253261
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.
    Hoffmann MF; Burgers TA; Mason JJ; Williams BO; Sietsema DL; Jones CB
    Injury; 2014 Jul; 45(7):1035-41. PubMed ID: 24680467
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dall-Miles cable and plate fixation system in the treatment of periprosthetic femoral fractures: a review of 20 cases.
    Sandhu R; Avramidis K; Johnson-Nurse C
    J Orthop Surg (Hong Kong); 2005 Dec; 13(3):259-66. PubMed ID: 16365489
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Principles of internal fixation and selection of implants for periprosthetic femoral fractures.
    Giannoudis PV; Kanakaris NK; Tsiridis E
    Injury; 2007 Jun; 38(6):669-87. PubMed ID: 17467709
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mennen plate fixation for the treatment of periprosthetic femoral fractures.
    Mennen U
    J Bone Joint Surg Am; 2003 Nov; 85(11):2248-9; author reply 2249. PubMed ID: 14630863
    [No Abstract]   [Full Text] [Related]  

  • 18. Management of periprosthetic femur fractures with a first generation locking plate.
    Fulkerson E; Tejwani N; Stuchin S; Egol K
    Injury; 2007 Aug; 38(8):965-72. PubMed ID: 17561020
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cable plates and onlay allografts in periprosthetic femoral fractures after hip replacement: laboratory and clinical observations.
    Howell JR; Masri BA; Garbuz DS; Greidanus NV; Duncan CP
    Instr Course Lect; 2004; 53():99-110. PubMed ID: 15116604
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures.
    Buttaro MA; Farfalli G; Paredes Núñez M; Comba F; Piccaluga F
    J Bone Joint Surg Am; 2007 Sep; 89(9):1964-9. PubMed ID: 17768193
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.