285 related articles for article (PubMed ID: 17124338)
1. Removal of ocular artifacts from EEG using adaptive thresholding of wavelet coefficients.
Krishnaveni V; Jayaraman S; Anitha L; Ramadoss K
J Neural Eng; 2006 Dec; 3(4):338-46. PubMed ID: 17124338
[TBL] [Abstract][Full Text] [Related]
2. Automatic removal of eye movement and blink artifacts from EEG data using blind component separation.
Joyce CA; Gorodnitsky IF; Kutas M
Psychophysiology; 2004 Mar; 41(2):313-25. PubMed ID: 15032997
[TBL] [Abstract][Full Text] [Related]
3. Removal of ocular artifact from the EEG: a review.
Croft RJ; Barry RJ
Neurophysiol Clin; 2000 Feb; 30(1):5-19. PubMed ID: 10740792
[TBL] [Abstract][Full Text] [Related]
4. Automatic removal of the eye blink artifact from EEG using an ICA-based template matching approach.
Li Y; Ma Z; Lu W; Li Y
Physiol Meas; 2006 Apr; 27(4):425-36. PubMed ID: 16537983
[TBL] [Abstract][Full Text] [Related]
5. A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements.
Kilicarslan A; Grossman RG; Contreras-Vidal JL
J Neural Eng; 2016 Apr; 13(2):026013. PubMed ID: 26863159
[TBL] [Abstract][Full Text] [Related]
6. Removing electroencephalographic artifacts by blind source separation.
Jung TP; Makeig S; Humphries C; Lee TW; McKeown MJ; Iragui V; Sejnowski TJ
Psychophysiology; 2000 Mar; 37(2):163-78. PubMed ID: 10731767
[TBL] [Abstract][Full Text] [Related]
7. Automatic removal of eye-movement and blink artifacts from EEG signals.
Gao JF; Yang Y; Lin P; Wang P; Zheng CX
Brain Topogr; 2010 Mar; 23(1):105-14. PubMed ID: 20039116
[TBL] [Abstract][Full Text] [Related]
8. Removing eye-movement artifacts from the EEG during the intracarotid amobarbital procedure.
Zhou W; Gotman J
Epilepsia; 2005 Mar; 46(3):409-14. PubMed ID: 15730538
[TBL] [Abstract][Full Text] [Related]
9. Removal of the ocular artifacts from EEG data using a cascaded spatio-temporal processing.
Liu T; Yao D
Comput Methods Programs Biomed; 2006 Aug; 83(2):95-103. PubMed ID: 16884816
[TBL] [Abstract][Full Text] [Related]
10. A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables: a simulation case.
Romero S; MaƱanas MA; Barbanoj MJ
Comput Biol Med; 2008 Mar; 38(3):348-60. PubMed ID: 18222418
[TBL] [Abstract][Full Text] [Related]
11. Artifact reduction for simultaneous EEG/fMRI recording: adaptive FIR reduction of imaging artifacts.
Wan X; Iwata K; Riera J; Kitamura M; Kawashima R
Clin Neurophysiol; 2006 Mar; 117(3):681-92. PubMed ID: 16458593
[TBL] [Abstract][Full Text] [Related]
12. A model-based objective evaluation of eye movement correction in EEG recordings.
Kierkels JJ; van Boxtel GJ; Vogten LL
IEEE Trans Biomed Eng; 2006 Feb; 53(2):246-53. PubMed ID: 16485753
[TBL] [Abstract][Full Text] [Related]
13. SURE-LET multichannel image denoising: interscale orthonormal wavelet thresholding.
Luisier F; Blu T
IEEE Trans Image Process; 2008 Apr; 17(4):482-92. PubMed ID: 18390357
[TBL] [Abstract][Full Text] [Related]
14. Online removal of eye movement and blink EEG artifacts using a high-speed eye tracker.
Noureddin B; Lawrence PD; Birch GE
IEEE Trans Biomed Eng; 2012 Aug; 59(8):2103-10. PubMed ID: 21278013
[TBL] [Abstract][Full Text] [Related]
15. Validation of ICA as a tool to remove eye movement artifacts from EEG/ERP.
Mennes M; Wouters H; Vanrumste B; Lagae L; Stiers P
Psychophysiology; 2010 Nov; 47(6):1142-50. PubMed ID: 20409015
[TBL] [Abstract][Full Text] [Related]
16. [Removal of artifacts from EEG signal].
Du X; Li Y; Zhu Y; Ren Q; Zhao L
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Apr; 25(2):464-7, 471. PubMed ID: 18610643
[TBL] [Abstract][Full Text] [Related]
17. An iterative subspace denoising algorithm for removing electroencephalogram ocular artifacts.
Sameni R; Gouy-Pailler C
J Neurosci Methods; 2014 Mar; 225():97-105. PubMed ID: 24486874
[TBL] [Abstract][Full Text] [Related]
18. High-throughput ocular artifact reduction in multichannel electroencephalography (EEG) using component subspace projection.
Ma J; Bayram S; Tao P; Svetnik V
J Neurosci Methods; 2011 Mar; 196(1):131-40. PubMed ID: 21236300
[TBL] [Abstract][Full Text] [Related]
19. Monte-Carlo sure: a black-box optimization of regularization parameters for general denoising algorithms.
Ramani S; Blu T; Unser M
IEEE Trans Image Process; 2008 Sep; 17(9):1540-54. PubMed ID: 18701393
[TBL] [Abstract][Full Text] [Related]
20. Removing muscle and eye artifacts using blind source separation techniques in ictal EEG source imaging.
Hallez H; De Vos M; Vanrumste B; Van Hese P; Assecondi S; Van Laere K; Dupont P; Van Paesschen W; Van Huffel S; Lemahieu I
Clin Neurophysiol; 2009 Jul; 120(7):1262-72. PubMed ID: 19539525
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]