166 related articles for article (PubMed ID: 17124539)
1. Lectin affinity chromatography using porous polymer monolith assisted nanoelectrospray MS/MS.
Bedair M; Oleschuk RD
Analyst; 2006 Dec; 131(12):1316-21. PubMed ID: 17124539
[TBL] [Abstract][Full Text] [Related]
2. Fabrication of porous polymer monoliths in polymeric microfluidic chips as an electrospray emitter for direct coupling to mass spectrometry.
Bedair MF; Oleschuk RD
Anal Chem; 2006 Feb; 78(4):1130-8. PubMed ID: 16478104
[TBL] [Abstract][Full Text] [Related]
3. High-performance affinity chromatography with immobilization of protein A and L-histidine on molded monolith.
Luo Q; Zou H; Zhang Q; Xiao X; Ni J
Biotechnol Bioeng; 2002 Dec; 80(5):481-9. PubMed ID: 12355458
[TBL] [Abstract][Full Text] [Related]
4. Multidimensional system enabling deglycosylation of proteins using a capillary reactor with peptide-N-glycosidase F immobilized on a porous polymer monolith and hydrophilic interaction liquid chromatography-mass spectrometry of glycans.
Krenkova J; Lacher NA; Svec F
J Chromatogr A; 2009 Apr; 1216(15):3252-9. PubMed ID: 19268959
[TBL] [Abstract][Full Text] [Related]
5. Integrated lectin affinity microfluidic chip for glycoform separation.
Mao X; Luo Y; Dai Z; Wang K; Du Y; Lin B
Anal Chem; 2004 Dec; 76(23):6941-7. PubMed ID: 15571345
[TBL] [Abstract][Full Text] [Related]
6. Preparation of glycerol dimethacrylate-based polymer monolith with unusual porous properties achieved via viscoelastic phase separation induced by monodisperse ultra high molecular weight poly(styrene) as a porogen.
Aoki H; Kubo T; Ikegami T; Tanaka N; Hosoya K; Tokuda D; Ishizuka N
J Chromatogr A; 2006 Jun; 1119(1-2):66-79. PubMed ID: 16513125
[TBL] [Abstract][Full Text] [Related]
7. Preparation of a monolithic capillary column with immobilized alpha-mannose for affinity chromatography of lectins.
Tetala KK; Chen B; Visser GM; Maruska A; Kornysova O; van Beek TA; Sudhölter EJ
J Biochem Biophys Methods; 2007 Feb; 70(1):63-9. PubMed ID: 17112595
[TBL] [Abstract][Full Text] [Related]
8. Analysis of glycopeptides using lectin affinity chromatography with MALDI-TOF mass spectrometry.
Kubota K; Sato Y; Suzuki Y; Goto-Inoue N; Toda T; Suzuki M; Hisanaga S; Suzuki A; Endo T
Anal Chem; 2008 May; 80(10):3693-8. PubMed ID: 18410132
[TBL] [Abstract][Full Text] [Related]
9. Porous polymer monolith assisted electrospray from a glass microdevice.
Koerner T; Oleschuk RD
Rapid Commun Mass Spectrom; 2005; 19(22):3279-86. PubMed ID: 16217844
[TBL] [Abstract][Full Text] [Related]
10. Development and characterization of an immunoaffinity monolith for selective on-line extraction of bisphenol A from environmental water samples.
Li L; Wang J; Zhou S; Zhao M
Anal Chim Acta; 2008 Jul; 620(1-2):1-7. PubMed ID: 18558118
[TBL] [Abstract][Full Text] [Related]
11. Poly (N-acryloxysuccinimide-co-ethylene glycol dimethacrylate) precursor monolith and its post polymerization modification with alkyl ligands, trypsin and lectins for reversed-phase chromatography, miniaturized enzyme reactors and lectin affinity chromatography, respectively.
Jonnada M; El Rassi Z
Electrophoresis; 2017 Nov; 38(22-23):2870-2879. PubMed ID: 28776699
[TBL] [Abstract][Full Text] [Related]
12. Porous polymer monolith assisted electrospray.
Koerner T; Turck K; Brown L; Oleschuk RD
Anal Chem; 2004 Nov; 76(21):6456-60. PubMed ID: 15516141
[TBL] [Abstract][Full Text] [Related]
13. Affinity monolithic capillary columns for glycomics/proteomics: 1. Polymethacrylate monoliths with immobilized lectins for glycoprotein separation by affinity capillary electrochromatography and affinity nano-liquid chromatography in either a single column or columns coupled in series.
Okanda FM; El Rassi Z
Electrophoresis; 2006 Mar; 27(5-6):1020-30. PubMed ID: 16470784
[TBL] [Abstract][Full Text] [Related]
14. Preparation and characterization of polyethyleneimine modified ion-exchanger based on poly(methacrylate-co-ethylene dimethacrylate) monolith.
Wang M; Xu J; Zhou X; Tan T
J Chromatogr A; 2007 Apr; 1147(1):24-9. PubMed ID: 17350638
[TBL] [Abstract][Full Text] [Related]
15. Affinity chromatography with monolithic capillary columns I. Polymethacrylate monoliths with immobilized mannan for the separation of mannose-binding proteins by capillary electrochromatography and nano-scale liquid chromatography.
Bedair M; El Rassi Z
J Chromatogr A; 2004 Jul; 1044(1-2):177-86. PubMed ID: 15354437
[TBL] [Abstract][Full Text] [Related]
16. Parameters governing reproducibility of flow properties of porous monoliths photopatterned within microfluidic channels.
He M; Bao JB; Zeng Y; Harrison DJ
Electrophoresis; 2010 Jul; 31(14):2422-8. PubMed ID: 20568261
[TBL] [Abstract][Full Text] [Related]
17. Preparation and evaluation of hydroxylated poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolithic capillary for in-tube solid-phase microextraction coupled to high-performance liquid chromatography.
Wen Y; Feng YQ
J Chromatogr A; 2007 Aug; 1160(1-2):90-8. PubMed ID: 17559862
[TBL] [Abstract][Full Text] [Related]
18. Development of an epoxy-based monolith used for the affinity capturing of Escherichia coli bacteria.
Peskoller C; Niessner R; Seidel M
J Chromatogr A; 2009 May; 1216(18):3794-801. PubMed ID: 19272606
[TBL] [Abstract][Full Text] [Related]
19. An evaluation of the performance of porous polymer monolith assisted electrospray.
Lee SS; Douma M; Koerner T; Oleschuk RD
Rapid Commun Mass Spectrom; 2005; 19(18):2671-80. PubMed ID: 16124028
[TBL] [Abstract][Full Text] [Related]
20. Effect of the matrix structure and concentration of polymer-immobilized Ni2+-iminodiacetic acid complexes on retention of IgG1.
Krácalíková K; Tishchenko G; Bleha M
J Biochem Biophys Methods; 2006 Apr; 67(1):7-25. PubMed ID: 16466797
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]