BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

241 related articles for article (PubMed ID: 17124844)

  • 1. Proximal interphalangeal joint arthrodesis using a combination plate-screw technique in 53 horses (1994-2003).
    Knox PM; Watkins JP
    Equine Vet J; 2006 Nov; 38(6):538-42. PubMed ID: 17124844
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Retrospective analysis of factors associated with outcome of proximal interphalangeal joint arthrodesis in 82 horses including Warmblood and Thoroughbred sport horses and Quarter Horses (1992-2014).
    Herthel TD; Rick MC; Judy CE; Cohen ND; Herthel DJ
    Equine Vet J; 2016 Sep; 48(5):557-64. PubMed ID: 26289294
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Proximal interphalangeal arthrodesis in 22 horses.
    Schaer TP; Bramlage LR; Embertson RM; Hance S
    Equine Vet J; 2001 Jul; 33(4):360-5. PubMed ID: 11469768
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A mechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial locking compression plate and two abaxial transarticular cortical screws versus an axial dynamic compression plate and two abaxial transarticular cortical screws.
    Sod GA; Riggs LM; Mitchell CF; Martin GS
    Vet Surg; 2011 Jul; 40(5):571-8. PubMed ID: 21521241
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion.
    Sod GA; Riggs LM; Mitchell CF; Hubert JD; Martin GS
    Vet Surg; 2010 Jan; 39(1):83-90. PubMed ID: 20210950
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Proximal interphalangeal joint arthrodesis in 34 horses using two parallel 5.5-mm cortical bone screws.
    MacLellan KN; Crawford WH; MacDonald DG
    Vet Surg; 2001; 30(5):454-9. PubMed ID: 11555821
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vitro biomechanical comparison of a 4.5 mm narrow locking compression plate construct versus a 4.5 mm limited contact dynamic compression plate construct for arthrodesis of the equine proximal interphalangeal joint.
    Ahern BJ; Showalter BL; Elliott DM; Richardson DW; Getman LM
    Vet Surg; 2013 Apr; 42(3):335-9. PubMed ID: 23445267
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion.
    Sod GA; Mitchell CF; Hubert JD; Martin GS; Gill MS
    Vet Surg; 2007 Dec; 36(8):792-9. PubMed ID: 18067621
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 3-hole 4.5 mm locking compression plate and 3-hole 4.5 mm narrow dynamic compression plate, with two transarticular 5.5 mm cortex screws.
    Zoppa AL; Santoni B; Puttlitz CM; Cochran K; Hendrickson DA
    Vet Surg; 2011 Feb; 40(2):253-9. PubMed ID: 21244444
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Proximal interphalangeal locking compression plate for pastern arthrodesis in horses.
    Hicks RB; Glass KG; Watkins JP
    Equine Vet J; 2021 Jun; ():. PubMed ID: 34060117
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Minimally invasive proximal interphalangeal joint arthrodesis using a locking compression plate and tissue engineering in horses: a pilot study.
    Seo JP; Yamaga T; Tsuzuki N; Yamada K; Haneda S; Furuoka H; Tabata Y; Sasaki N
    Can Vet J; 2014 Nov; 55(11):1050-6. PubMed ID: 25392547
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of two 7-hole 3.5-mm broad and two 5-hole 4.5-mm narrow dynamic compression plates.
    Watt BC; Edwards RB; Markel MD; McCabe R; Wilson DG
    Vet Surg; 2002; 31(1):85-93. PubMed ID: 11778172
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Arthrodesis of the proximal interphalangeal joint in the horse: a cyclic biomechanical comparison of two and three parallel cortical screws inserted in lag fashion.
    Carmalt JL; Delaney L; Wilson DG
    Vet Surg; 2010 Jan; 39(1):91-4. PubMed ID: 20210951
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Arthrodesis of the pastern joint in the horse.
    Steenhaut M; Verschooten F; De Moor A
    Equine Vet J; 1985 Jan; 17(1):35-40. PubMed ID: 3979371
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of a 3-hole 4.5-mm Dynamic Compression Plate and a 7-hole 5.5-mm Y Locking Compression Plate for Arthrodesis of the Proximal Interphalangeal Joint in Horses-an Ex Vivo Biomechanical Study.
    Latorre CAS; de Souza AF; Ramos PAR; Nóbrega FS; van de Graaf GMM; Pereira CAM; Ferrigno CRA; Hendrickson DA; De Zoppa ALDV
    J Equine Vet Sci; 2020 Nov; 94():103252. PubMed ID: 33077103
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: two parallel transarticular headless tapered variable pitch screws versus two parallel transarticular AO cortical bone screws inserted in lag fashion.
    Gudehus T; Sod GA; Riggs LM; Mitchell CF; Martin GS
    Vet Surg; 2011 Apr; 40(3):261-5. PubMed ID: 21361995
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro biomechanical comparison of a 5-hole 4.5 mm locking compression plate and 5-hole 4.5 mm dynamic compression plate for equine proximal interphalangeal joint arthrodesis.
    Seo JP; Yamaga T; Tsuzuki N; Yamada K; Haneda S; Furuoka H; Sasaki N
    Vet Surg; 2014 Jul; 43(5):606-11. PubMed ID: 24512440
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term results and complications of proximal interphalangeal arthrodesis in horses.
    Martin GS; McIlwraith CW; Turner AS; Nixon AJ; Stashak TS
    J Am Vet Med Assoc; 1984 May; 184(9):1136-40. PubMed ID: 6725132
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of a locking compression plate for equine proximal interphalangeal joint arthrodesis: 29 cases (2008-2014).
    Sakai RR; Goodrich LR; Katzman SA; Moorman VJ; Leise BS; Kawcak CE; Galuppo LD
    J Am Vet Med Assoc; 2018 Dec; 253(11):1460-1466. PubMed ID: 30451612
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical use of the locking compression plate (LCP) in horses: a retrospective study of 31 cases (2004-2006).
    Levine DG; Richardson DW
    Equine Vet J; 2007 Sep; 39(5):401-6. PubMed ID: 17910263
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.