120 related articles for article (PubMed ID: 17125862)
1. Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning.
Bragg CM; Conway J
Radiother Oncol; 2006 Dec; 81(3):315-23. PubMed ID: 17125862
[TBL] [Abstract][Full Text] [Related]
2. Dosimetric verification of a commercial collapsed cone algorithm in simulated clinical situations.
Nisbet A; Beange I; Vollmar HS; Irvine C; Morgan A; Thwaites DI
Radiother Oncol; 2004 Oct; 73(1):79-88. PubMed ID: 15465150
[TBL] [Abstract][Full Text] [Related]
3. Clinical implications of the anisotropic analytical algorithm for IMRT treatment planning and verification.
Bragg CM; Wingate K; Conway J
Radiother Oncol; 2008 Feb; 86(2):276-84. PubMed ID: 18249453
[TBL] [Abstract][Full Text] [Related]
4. Validation of Varian's AAA algorithm with focus on lung treatments.
Rønde HS; Hoffmann L
Acta Oncol; 2009; 48(2):209-15. PubMed ID: 18803058
[TBL] [Abstract][Full Text] [Related]
5. On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations.
Fogliata A; Vanetti E; Albers D; Brink C; Clivio A; Knöös T; Nicolini G; Cozzi L
Phys Med Biol; 2007 Mar; 52(5):1363-85. PubMed ID: 17301460
[TBL] [Abstract][Full Text] [Related]
6. A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm.
Ding GX; Cygler JE; Yu CW; Kalach NI; Daskalov G
Int J Radiat Oncol Biol Phys; 2005 Oct; 63(2):622-33. PubMed ID: 16168854
[TBL] [Abstract][Full Text] [Related]
7. Application of GEANT4 radiation transport toolkit to dose calculations in anthropomorphic phantoms.
Rodrigues P; Trindade A; Peralta L; Alves C; Chaves A; Lopes MC
Appl Radiat Isot; 2004 Dec; 61(6):1451-61. PubMed ID: 15388147
[TBL] [Abstract][Full Text] [Related]
8. Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water.
Fogliata A; Nicolini G; Vanetti E; Clivio A; Cozzi L
Phys Med Biol; 2006 Mar; 51(6):1421-38. PubMed ID: 16510953
[TBL] [Abstract][Full Text] [Related]
9. Implementation and experimental validation of the high dose rate stereotactic treatment mode at Varian accelerators.
Hoffmann L
Acta Oncol; 2009; 48(2):201-8. PubMed ID: 18759143
[TBL] [Abstract][Full Text] [Related]
10. Comparison of 3D conformal breast radiation treatment plans using the anisotropic analytical algorithm and pencil beam convolution algorithm.
Yoo S; Wu Q; O'Daniel J; Horton J; Yin FF
Radiother Oncol; 2012 May; 103(2):172-7. PubMed ID: 22349127
[TBL] [Abstract][Full Text] [Related]
11. The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: implications for tumour coverage.
Aarup LR; Nahum AE; Zacharatou C; Juhler-Nøttrup T; Knöös T; Nyström H; Specht L; Wieslander E; Korreman SS
Radiother Oncol; 2009 Jun; 91(3):405-14. PubMed ID: 19297051
[TBL] [Abstract][Full Text] [Related]
12. Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases.
Hasenbalg F; Neuenschwander H; Mini R; Born EJ
Phys Med Biol; 2007 Jul; 52(13):3679-91. PubMed ID: 17664570
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric evaluation of a Monte Carlo IMRT treatment planning system incorporating the MIMiC.
Rassiah-Szegedi P; Fuss M; Sheikh-Bagheri D; Szegedi M; Stathakis S; Lancaster J; Papanikolaou N; Salter B
Phys Med Biol; 2007 Dec; 52(23):6931-41. PubMed ID: 18029985
[TBL] [Abstract][Full Text] [Related]
14. An independent dose calculation algorithm for MLC-based radiotherapy including the spatial dependence of MLC transmission.
Lorenz F; Nalichowski A; Rosca F; Killoran J; Wenz F; Zygmanski P
Phys Med Biol; 2008 Feb; 53(3):557-73. PubMed ID: 18199902
[TBL] [Abstract][Full Text] [Related]
15. A preliminary study of in-house Monte Carlo simulations: an integrated Monte Carlo verification system.
Mukumoto N; Tsujii K; Saito S; Yasunaga M; Takegawa H; Yamamoto T; Numasaki H; Teshima T
Int J Radiat Oncol Biol Phys; 2009 Oct; 75(2):571-9. PubMed ID: 19735883
[TBL] [Abstract][Full Text] [Related]
16. Patient-specific IMRT verification using independent fluence-based dose calculation software: experimental benchmarking and initial clinical experience.
Georg D; Stock M; Kroupa B; Olofsson J; Nyholm T; Ahnesjö A; Karlsson M
Phys Med Biol; 2007 Aug; 52(16):4981-92. PubMed ID: 17671348
[TBL] [Abstract][Full Text] [Related]
17. Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm.
Newhauser W; Fontenot J; Zheng Y; Polf J; Titt U; Koch N; Zhang X; Mohan R
Phys Med Biol; 2007 Aug; 52(15):4569-84. PubMed ID: 17634651
[TBL] [Abstract][Full Text] [Related]
18. SBRT of lung tumours: Monte Carlo simulation with PENELOPE of dose distributions including respiratory motion and comparison with different treatment planning systems.
Panettieri V; Wennberg B; Gagliardi G; Duch MA; Ginjaume M; Lax I
Phys Med Biol; 2007 Jul; 52(14):4265-81. PubMed ID: 17664607
[TBL] [Abstract][Full Text] [Related]
19. [Electron fields in clinical application. A comparison of pencil beam and Monte Carlo algorithm].
Treutwein M; Bogner L
Strahlenther Onkol; 2007 Aug; 183(8):454-8. PubMed ID: 17680226
[TBL] [Abstract][Full Text] [Related]
20. The implementation of an advanced treatment planning algorithm in the treatment of lung cancer with conventional radiotherapy.
Pearson M; Atherton P; McMenemin R; McDonald F; Mazdai G; Mulvenna P; Lambert G
Clin Oncol (R Coll Radiol); 2009 Apr; 21(3):168-74. PubMed ID: 19162457
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]