These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

353 related articles for article (PubMed ID: 17126038)

  • 21. Effect of spatial smoothing on physiological noise in high-resolution fMRI.
    Triantafyllou C; Hoge RD; Wald LL
    Neuroimage; 2006 Aug; 32(2):551-7. PubMed ID: 16815038
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Improving the spatial accuracy in functional magnetic resonance imaging (fMRI) based on the blood oxygenation level dependent (BOLD) effect: benefits from parallel imaging and a 32-channel head array coil at 1.5 Tesla.
    Fellner C; Doenitz C; Finkenzeller T; Jung EM; Rennert J; Schlaier J
    Clin Hemorheol Microcirc; 2009; 43(1-2):71-82. PubMed ID: 19713602
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Analysis of physiological noise in quantitative cardiac magnetic resonance.
    Jao T; Nayak K
    PLoS One; 2019; 14(8):e0214566. PubMed ID: 31454354
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Physiological noise effects on the flip angle selection in BOLD fMRI.
    Gonzalez-Castillo J; Roopchansingh V; Bandettini PA; Bodurka J
    Neuroimage; 2011 Feb; 54(4):2764-78. PubMed ID: 21073963
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Physiological Contribution in Spontaneous Oscillations: An Approximate Quality-Assurance Index for Resting-State fMRI Signals.
    Hsu AL; Chou KH; Chao YP; Fan HY; Wu CW; Chen JH
    PLoS One; 2016; 11(2):e0148393. PubMed ID: 26871897
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Improved BOLD detection in the medial temporal region using parallel imaging and voxel volume reduction.
    Bellgowan PS; Bandettini PA; van Gelderen P; Martin A; Bodurka J
    Neuroimage; 2006 Feb; 29(4):1244-51. PubMed ID: 16242347
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A geometric view of signal sensitivity metrics in multi-echo fMRI.
    Liu TT; Li B; Fernandez B; Banerjee S
    Neuroimage; 2022 Oct; 259():119409. PubMed ID: 35752411
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Detectability and reproducibility of the olfactory fMRI signal under the influence of magnetic susceptibility artifacts in the primary olfactory cortex.
    Lu J; Wang X; Qing Z; Li Z; Zhang W; Liu Y; Yuan L; Cheng L; Li M; Zhu B; Zhang X; Yang QX; Zhang B
    Neuroimage; 2018 Sep; 178():613-621. PubMed ID: 29885483
    [TBL] [Abstract][Full Text] [Related]  

  • 29. EEG-assisted retrospective motion correction for fMRI: E-REMCOR.
    Zotev V; Yuan H; Phillips R; Bodurka J
    Neuroimage; 2012 Nov; 63(2):698-712. PubMed ID: 22836172
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Trading off spatio-temporal properties in 3D high-speed fMRI using interleaved stack-of-spirals trajectories.
    Riemenschneider B; Akin B; LeVan P; Hennig J
    Magn Reson Med; 2021 Aug; 86(2):777-790. PubMed ID: 33749021
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Information content of SNR/resolution trade-offs in three-dimensional magnetic resonance imaging.
    Portnoy S; Kale SC; Feintuch A; Tardif C; Pike GB; Henkelman RM
    Med Phys; 2009 Apr; 36(4):1442-51. PubMed ID: 19472651
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of SLIce Dithered Enhanced Resolution Simultaneous MultiSlice (SLIDER-SMS) for human fMRI.
    Vu AT; Beckett A; Setsompop K; Feinberg DA
    Neuroimage; 2018 Jan; 164():164-171. PubMed ID: 28185951
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Signal fluctuations in fMRI data acquired with 2D-EPI and 3D-EPI at 7 Tesla.
    Jorge J; Figueiredo P; van der Zwaag W; Marques JP
    Magn Reson Imaging; 2013 Feb; 31(2):212-20. PubMed ID: 22921734
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Multiband echo-shifted echo planar imaging.
    Boyacioğlu R; Schulz J; Norris DG
    Magn Reson Med; 2017 May; 77(5):1981-1986. PubMed ID: 27297682
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of matched BOLD and FAIR 4.0T-fMRI with [15O]water PET brain volumes.
    Zaini MR; Strother SC; Anderson JR; Liow JS; Kjems U; Tegeler C; Kim SG
    Med Phys; 1999 Aug; 26(8):1559-67. PubMed ID: 10501056
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters.
    Triantafyllou C; Hoge RD; Krueger G; Wiggins CJ; Potthast A; Wiggins GC; Wald LL
    Neuroimage; 2005 May; 26(1):243-50. PubMed ID: 15862224
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The Impact of Spatial Normalization Strategies on the Temporal Features of the Resting-State Functional MRI: Spatial Normalization Before rs-fMRI Features Calculation May Reduce the Reliability.
    Qing Z; Zhang X; Ye M; Wu S; Wang X; Nedelska Z; Hort J; Zhu B; Zhang B
    Front Neurosci; 2019; 13():1249. PubMed ID: 31849578
    [TBL] [Abstract][Full Text] [Related]  

  • 38. High spatio-temporal resolution in functional MRI with 3D echo planar imaging using cylindrical excitation and a CAIPIRINHA undersampling pattern.
    van der Zwaag W; Reynaud O; Narsude M; Gallichan D; Marques JP
    Magn Reson Med; 2018 May; 79(5):2589-2596. PubMed ID: 28905414
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Integration of EEG source imaging and fMRI during continuous viewing of natural movies.
    Whittingstall K; Bartels A; Singh V; Kwon S; Logothetis NK
    Magn Reson Imaging; 2010 Oct; 28(8):1135-42. PubMed ID: 20579829
    [TBL] [Abstract][Full Text] [Related]  

  • 40. High-resolution whole-brain diffusion MRI at 7T using radiofrequency parallel transmission.
    Wu X; Auerbach EJ; Vu AT; Moeller S; Lenglet C; Schmitter S; Van de Moortele PF; Yacoub E; Uğurbil K
    Magn Reson Med; 2018 Nov; 80(5):1857-1870. PubMed ID: 29603381
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.