266 related articles for article (PubMed ID: 17126064)
1. Semi-automatic level-set based segmentation and stenosis quantification of the internal carotid artery in 3D CTA data sets.
Scherl H; Hornegger J; Prümmer M; Lell M
Med Image Anal; 2007 Feb; 11(1):21-34. PubMed ID: 17126064
[TBL] [Abstract][Full Text] [Related]
2. Level set based cerebral vasculature segmentation and diameter quantification in CT angiography.
Manniesing R; Velthuis BK; van Leeuwen MS; van der Schaaf IC; van Laar PJ; Niessen WJ
Med Image Anal; 2006 Apr; 10(2):200-14. PubMed ID: 16263325
[TBL] [Abstract][Full Text] [Related]
3. Evaluation framework for carotid bifurcation lumen segmentation and stenosis grading.
Hameeteman K; Zuluaga MA; Freiman M; Joskowicz L; Cuisenaire O; Valencia LF; Gülsün MA; Krissian K; Mille J; Wong WC; Orkisz M; Tek H; Hoyos MH; Benmansour F; Chung AC; Rozie S; van Gils M; van den Borne L; Sosna J; Berman P; Cohen N; Douek PC; Sánchez I; Aissat M; Schaap M; Metz CT; Krestin GP; van der Lugt A; Niessen WJ; van Walsum T
Med Image Anal; 2011 Aug; 15(4):477-88. PubMed ID: 21419689
[TBL] [Abstract][Full Text] [Related]
4. Automatic segmentation of intracranial arteries and veins in four-dimensional cerebral CT perfusion scans.
Mendrik A; Vonken EJ; van Ginneken B; Smit E; Waaije A; Bertolini G; Viergever MA; Prokop M
Med Phys; 2010 Jun; 37(6):2956-66. PubMed ID: 20632608
[TBL] [Abstract][Full Text] [Related]
5. 3D ultrasound analysis of carotid plaque volume and surface morphology.
Fenster A; Blake C; Gyacskov I; Landry A; Spence JD
Ultrasonics; 2006 Dec; 44 Suppl 1():e153-7. PubMed ID: 16844159
[TBL] [Abstract][Full Text] [Related]
6. Automatic initialization algorithm for carotid artery segmentation in CTA images.
Sanderse M; Marquering HA; Hendriks EA; van der Lugt A; Reiber JH
Med Image Comput Comput Assist Interv; 2005; 8(Pt 2):846-53. PubMed ID: 16686039
[TBL] [Abstract][Full Text] [Related]
7. Robust CTA lumen segmentation of the atherosclerotic carotid artery bifurcation in a large patient population.
Manniesing R; Schaap M; Rozie S; Hameeteman R; Vukadinovic D; van der Lugt A; Niessen W
Med Image Anal; 2010 Dec; 14(6):759-69. PubMed ID: 20605737
[TBL] [Abstract][Full Text] [Related]
8. Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography.
Kirişli HA; Schaap M; Metz CT; Dharampal AS; Meijboom WB; Papadopoulou SL; Dedic A; Nieman K; de Graaf MA; Meijs MF; Cramer MJ; Broersen A; Cetin S; Eslami A; Flórez-Valencia L; Lor KL; Matuszewski B; Melki I; Mohr B; Oksüz I; Shahzad R; Wang C; Kitslaar PH; Unal G; Katouzian A; Örkisz M; Chen CM; Precioso F; Najman L; Masood S; Ünay D; van Vliet L; Moreno R; Goldenberg R; Vuçini E; Krestin GP; Niessen WJ; van Walsum T
Med Image Anal; 2013 Dec; 17(8):859-76. PubMed ID: 23837963
[TBL] [Abstract][Full Text] [Related]
9. Semiautomatic vessel wall detection and quantification of wall thickness in computed tomography images of human abdominal aortic aneurysms.
Shum J; DiMartino ES; Goldhamme A; Goldman DH; Acker LC; Patel G; Ng JH; Martufi G; Finol EA
Med Phys; 2010 Feb; 37(2):638-48. PubMed ID: 20229873
[TBL] [Abstract][Full Text] [Related]
10. Nonrigid registration-based coronary artery motion correction for cardiac computed tomography.
Bhagalia R; Pack JD; Miller JV; Iatrou M
Med Phys; 2012 Jul; 39(7):4245-54. PubMed ID: 22830758
[TBL] [Abstract][Full Text] [Related]
11. Semiautomatic segmentation of atherosclerotic carotid artery wall volume using 3D ultrasound imaging.
Hossain MM; AlMuhanna K; Zhao L; Lal BK; Sikdar S
Med Phys; 2015 Apr; 42(4):2029-43. PubMed ID: 25832093
[TBL] [Abstract][Full Text] [Related]
12. Coronary lumen segmentation using graph cuts and robust kernel regression.
Schaap M; Neefjes L; Metz C; van der Giessen A; Weustink A; Mollet N; Wentzel J; van Walsum TW; Niessen W
Inf Process Med Imaging; 2009; 21():528-39. PubMed ID: 19694291
[TBL] [Abstract][Full Text] [Related]
13. Cranial computed tomography angiography with automated bone subtraction: a feasibility study.
Lell MM; Ruehm SG; Kramer M; Panknin C; Habibi R; Klotz E; Villablanca P
Invest Radiol; 2009 Jan; 44(1):38-43. PubMed ID: 18836384
[TBL] [Abstract][Full Text] [Related]
14. Fully automatic plaque segmentation in 3-D carotid ultrasound images.
Cheng J; Li H; Xiao F; Fenster A; Zhang X; He X; Li L; Ding M
Ultrasound Med Biol; 2013 Dec; 39(12):2431-46. PubMed ID: 24063959
[TBL] [Abstract][Full Text] [Related]
15. Internal carotid artery stenosis measurements from 3D reconstructed multi-directional views using phantom data set on MRA image sequence.
Kim DY; Park JW
Eur J Radiol; 2009 Oct; 72(1):65-74. PubMed ID: 18619751
[TBL] [Abstract][Full Text] [Related]
16. Quantification of coronary arterial stenoses in CTA using fuzzy distance transform.
Xu Y; Liang G; Hu G; Yang Y; Geng J; Saha PK
Comput Med Imaging Graph; 2012 Jan; 36(1):11-24. PubMed ID: 21555207
[TBL] [Abstract][Full Text] [Related]
17. Three-dimensional morphological analysis of intracranial aneurysms: a fully automated method for aneurysm sac isolation and quantification.
Larrabide I; Cruz Villa-Uriol M; Cárdenes R; Pozo JM; Macho J; San Roman L; Blasco J; Vivas E; Marzo A; Hose DR; Frangi AF
Med Phys; 2011 May; 38(5):2439-49. PubMed ID: 21776779
[TBL] [Abstract][Full Text] [Related]
18. Atlas-driven lung lobe segmentation in volumetric X-ray CT images.
Zhang L; Hoffman EA; Reinhardt JM
IEEE Trans Med Imaging; 2006 Jan; 25(1):1-16. PubMed ID: 16398410
[TBL] [Abstract][Full Text] [Related]
19. Carotid artery stenosis: performance of advanced vessel analysis software in evaluating CTA.
Tsiflikas I; Biermann C; Thomas C; Ketelsen D; Claussen CD; Heuschmid M
Eur J Radiol; 2012 Sep; 81(9):2255-9. PubMed ID: 21930358
[TBL] [Abstract][Full Text] [Related]
20. A segmentation and reconstruction technique for 3D vascular structures.
Luboz V; Wu X; Krissian K; Westin CF; Kikinis R; Cotin S; Dawson S
Med Image Comput Comput Assist Interv; 2005; 8(Pt 1):43-50. PubMed ID: 16685827
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]