These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
162 related articles for article (PubMed ID: 17131070)
1. The single-staged approach to the surgical management of abdominal wall hernias in contaminated fields. Alaedeen DI; Lipman J; Medalie D; Rosen MJ Hernia; 2007 Feb; 11(1):41-5. PubMed ID: 17131070 [TBL] [Abstract][Full Text] [Related]
2. A 5-year clinical experience with single-staged repairs of infected and contaminated abdominal wall defects utilizing biologic mesh. Rosen MJ; Krpata DM; Ermlich B; Blatnik JA Ann Surg; 2013 Jun; 257(6):991-6. PubMed ID: 23426340 [TBL] [Abstract][Full Text] [Related]
3. Laparoscopic component separation in the single-stage treatment of infected abdominal wall prosthetic removal. Rosen MJ; Jin J; McGee MF; Williams C; Marks J; Ponsky JL Hernia; 2007 Oct; 11(5):435-40. PubMed ID: 17646896 [TBL] [Abstract][Full Text] [Related]
4. Preliminary results of a two-layered prosthetic repair for recurrent inguinal and ventral hernias combining open and laparoscopic techniques. Treviño JM; Franklin ME; Berghoff KR; Glass JL; Jaramillo EJ Hernia; 2006 Jun; 10(3):253-7. PubMed ID: 16609818 [TBL] [Abstract][Full Text] [Related]
5. Use of porcine small intestinal submucosa as a prosthetic device for laparoscopic repair of hernias in contaminated fields: 2-year follow-up. Franklin ME; Gonzalez JJ; Glass JL Hernia; 2004 Aug; 8(3):186-9. PubMed ID: 14991410 [TBL] [Abstract][Full Text] [Related]
6. Use of human acellular dermal matrix for hernia repair: friend or foe? Candage R; Jones K; Luchette FA; Sinacore JM; Vandevender D; Reed RL Surgery; 2008 Oct; 144(4):703-9; discussion 709-11. PubMed ID: 18847657 [TBL] [Abstract][Full Text] [Related]
7. Outcomes Analysis of Biologic Mesh Use for Abdominal Wall Reconstruction in Clean-Contaminated and Contaminated Ventral Hernia Repair. Sbitany H; Kwon E; Chern H; Finlayson E; Varma MG; Hansen SL Ann Plast Surg; 2015 Aug; 75(2):201-4. PubMed ID: 24317239 [TBL] [Abstract][Full Text] [Related]
8. Polyester-based mesh for ventral hernia repair: is it safe? Rosen MJ Am J Surg; 2009 Mar; 197(3):353-9. PubMed ID: 19245914 [TBL] [Abstract][Full Text] [Related]
9. Active Staphylococcus aureus infection: Is it a contra-indication to the repair of complex hernias with synthetic mesh? A prospective observational study on the outcomes of synthetic mesh replacement, in patients with chronic mesh infection caused by Staphylococcus aureus. Birolini C; de Miranda JS; Utiyama EM; Rasslan S; Birolini D Int J Surg; 2016 Apr; 28():56-62. PubMed ID: 26912016 [TBL] [Abstract][Full Text] [Related]
10. Reliable complex abdominal wall hernia repairs with a narrow, well-fixed retrorectus polypropylene mesh: A review of over 100 consecutive cases. Lanier ST; Fligor JE; Miller KR; Dumanian GA Surgery; 2016 Dec; 160(6):1508-1516. PubMed ID: 27545993 [TBL] [Abstract][Full Text] [Related]
11. Use of polypropylene mesh in the management of a contaminated large ventral hernia: a contraindication or a solution? Yang F Am Surg; 2013 Dec; 79(12):1298-303. PubMed ID: 24351360 [TBL] [Abstract][Full Text] [Related]
12. A dual-stage approach to contaminated, high-risk ventral hernia repairs. Kugler NW; Bobbs M; Webb T; Carver TW; Milia D; Paul JS J Surg Res; 2016 Jul; 204(1):200-4. PubMed ID: 27451887 [TBL] [Abstract][Full Text] [Related]
13. The safety and efficacy of prosthetic hernia repair in clean-contaminated and contaminated wounds. Kelly ME; Behrman SW Am Surg; 2002 Jun; 68(6):524-8; discussion 528-9. PubMed ID: 12079133 [TBL] [Abstract][Full Text] [Related]
14. Preliminary experience with new bioactive prosthetic material for repair of hernias in infected fields. Franklin ME; Gonzalez JJ; Michaelson RP; Glass JL; Chock DA Hernia; 2002 Dec; 6(4):171-4. PubMed ID: 12424595 [TBL] [Abstract][Full Text] [Related]
16. Open retromuscular mesh repair of complex incisional hernia: predictors of wound events and recurrence. Cobb WS; Warren JA; Ewing JA; Burnikel A; Merchant M; Carbonell AM J Am Coll Surg; 2015 Apr; 220(4):606-13. PubMed ID: 25797746 [TBL] [Abstract][Full Text] [Related]
17. Outcomes of the fascial component separation technique with synthetic mesh reinforcement for repair of complex ventral incisional hernias in the morbidly obese. Moore M; Bax T; MacFarlane M; McNevin MS Am J Surg; 2008 May; 195(5):575-9; discussion 579. PubMed ID: 18374893 [TBL] [Abstract][Full Text] [Related]
18. Complex abdominal wall reconstruction in the setting of active infection and contamination: a systematic review of hernia and fistula recurrence rates. Hodgkinson JD; Maeda Y; Leo CA; Warusavitarne J; Vaizey CJ Colorectal Dis; 2017 Apr; 19(4):319-330. PubMed ID: 28102927 [TBL] [Abstract][Full Text] [Related]
19. Pelvic, abdominal, and chest wall reconstruction with AlloDerm in patients at increased risk for mesh-related complications. Butler CE; Langstein HN; Kronowitz SJ Plast Reconstr Surg; 2005 Oct; 116(5):1263-75; discussion 1276-7. PubMed ID: 16217466 [TBL] [Abstract][Full Text] [Related]