170 related articles for article (PubMed ID: 17131624)
1. Advances in serum protein electrophoresis.
Bossuyt X
Adv Clin Chem; 2006; 42():43-80. PubMed ID: 17131624
[TBL] [Abstract][Full Text] [Related]
2. Separation of serum proteins by automated capillary zone electrophoresis.
Bossuyt X
Clin Chem Lab Med; 2003 Jun; 41(6):762-72. PubMed ID: 12880139
[TBL] [Abstract][Full Text] [Related]
3. Automated serum protein electrophoresis by Capillarys.
Bossuyt X; Lissoir B; Mariƫn G; Maisin D; Vunckx J; Blanckaert N; Wallemacq P
Clin Chem Lab Med; 2003 May; 41(5):704-10. PubMed ID: 12812271
[TBL] [Abstract][Full Text] [Related]
4. Comparison of serum protein electrophoresis by agarose gel and capillary zone electrophoresis in a clinical setting.
Jolliff CR; Blessum CR
Electrophoresis; 1997 Sep; 18(10):1781-4. PubMed ID: 9372270
[TBL] [Abstract][Full Text] [Related]
5. Serum proteins by capillary zone electrophoresis: approaches to the definition of reference values.
Petrini C; Alessio MG; Scapellato L; Brambilla S; Franzini C
Clin Chem Lab Med; 1999 Oct; 37(10):975-80. PubMed ID: 10616752
[TBL] [Abstract][Full Text] [Related]
6. Performance of the Sebia CAPILLARYS 2 for detection and immunotyping of serum monoclonal paraproteins.
Yang Z; Harrison K; Park YA; Chaffin CH; Thigpen B; Easley PL; Smith JA; Robinson CA; Lorenz RG; Hardy RW
Am J Clin Pathol; 2007 Aug; 128(2):293-9. PubMed ID: 17638665
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of a capillary zone electrophoresis system versus a conventional agarose gel system for routine serum protein separation and monoclonal component typing.
Roudiere L; Boularan AM; Bonardet A; Vallat C; Cristol JP; Dupuy AM
Clin Lab; 2006; 52(1-2):19-27. PubMed ID: 16506360
[TBL] [Abstract][Full Text] [Related]
8. Multicenter evaluation of the Paragon CZE 2000 capillary zone electrophoresis system for serum protein electrophoresis and monoclonal component typing.
Bienvenu J; Graziani MS; Arpin F; Bernon H; Blessum C; Marchetti C; Righetti G; Somenzini M; Verga G; Aguzzi F
Clin Chem; 1998 Mar; 44(3):599-605. PubMed ID: 9510868
[TBL] [Abstract][Full Text] [Related]
9. Determination of poorly separated monoclonal serum proteins by capillary zone electrophoresis.
Le Bricon T; Launay E; Houze P; Bengoufa D; Bousquet B; Gourmel B
J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Jul; 775(1):63-70. PubMed ID: 12101061
[TBL] [Abstract][Full Text] [Related]
10. Measurement of serum monoclonal components: comparison between densitometry and capillary zone electrophoresis.
Mussap M; Pietrogrande F; Ponchia S; Stefani PM; Sartori R; Plebani M
Clin Chem Lab Med; 2006; 44(5):609-11. PubMed ID: 16681432
[TBL] [Abstract][Full Text] [Related]
11. Precision and long-term stability of capillary electrophoresis measurement of serum protein zones.
Luraschi P; Brambilla S; Infusino I; Franzini C
Clin Chim Acta; 2003 Jul; 333(1):41-5. PubMed ID: 12809733
[TBL] [Abstract][Full Text] [Related]
12. Routine differential diagnosis of proteinurias by capillary electrophoresis.
Kolios G; Bairaktari E; Tsolas O; Seferiadis K
Clin Chem Lab Med; 2001 Sep; 39(9):784-8. PubMed ID: 11601673
[TBL] [Abstract][Full Text] [Related]
13. [The Paragon CZE 2000 and the Hydrasys Hyrys for electrophoresis of serum proteins and serum monoclonal antibody typing].
Godey F; Ropert M; Bouasria A; Lucas-Clerc C; Guenet L; Savoure N; Treut AL
Ann Biol Clin (Paris); 1999 May; 57(3):337-44. PubMed ID: 10377487
[No Abstract] [Full Text] [Related]
14. [Serum protein electrophoresis: comparison of capillary zone electrophoresis Capillarys (Sebia) and agarose gel electrophoresis Hydrasys (Sebia)].
Lissoir B; Wallemacq P; Maisin D
Ann Biol Clin (Paris); 2003; 61(5):557-62. PubMed ID: 14671753
[TBL] [Abstract][Full Text] [Related]
15. Interpretation of capillary zone electrophoresis compared with cellulose acetate and agarose gel electrophoresis: reference intervals and diagnostic efficiency in dogs and cats.
Giordano A; Paltrinieri S
Vet Clin Pathol; 2010 Dec; 39(4):464-73. PubMed ID: 21039711
[TBL] [Abstract][Full Text] [Related]
16. Utility of serum indices in a particular case of serum protein electrophoresis.
Daves M; Piccin A; Vicidomini C; De Luisi A; Mega A
Biochem Med (Zagreb); 2022 Oct; 32(3):030802. PubMed ID: 35966258
[TBL] [Abstract][Full Text] [Related]
17. Rapid capillary electrophoretic analysis of human serum proteins: qualitative comparison with high-throughput agarose gel electrophoresis.
Clark R; Katzmann JA; Wiegert E; Namyst-Goldberg C; Sanders L; Oda RP; Kyle RA; Landers JP
J Chromatogr A; 1996 Sep; 744(1-2):205-13. PubMed ID: 8843669
[TBL] [Abstract][Full Text] [Related]
18. Serum protein electrophoresis by CZE 2000 clinical capillary electrophoresis system.
Bossuyt X; Schiettekatte G; Bogaerts A; Blanckaert N
Clin Chem; 1998 Apr; 44(4):749-59. PubMed ID: 9554485
[TBL] [Abstract][Full Text] [Related]
19. Comparison between a second generation automated multicapillary electrophoresis system with an automated agarose gel electrophoresis system for the detection of M-components.
Larsson A; Hansson LO
Ups J Med Sci; 2008; 113(1):65-72. PubMed ID: 18521800
[TBL] [Abstract][Full Text] [Related]
20. Capillary zone electrophoresis of serum proteins: effects of changed analytical conditions.
Luraschi P; Dea ED; Franzini C
Clin Chem Lab Med; 2003 Jun; 41(6):782-6. PubMed ID: 12880141
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]