These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
117 related articles for article (PubMed ID: 17132444)
1. Time-resolved Fourier transform infrared spectroscopy of chemical reactions in solution using a focal plane array detector. Kaun N; Vellekoop MJ; Lendl B Appl Spectrosc; 2006 Nov; 60(11):1273-8. PubMed ID: 17132444 [TBL] [Abstract][Full Text] [Related]
2. Chemical fingerprinting of Arabidopsis using Fourier transform infrared (FT-IR) spectroscopic approaches. Gorzsás A; Sundberg B Methods Mol Biol; 2014; 1062():317-52. PubMed ID: 24057375 [TBL] [Abstract][Full Text] [Related]
3. Time-resolved mid-IR spectroscopy of (bio)chemical reactions in solution utilizing a new generation of continuous-flow micro-mixers. Wagner C; Buchegger W; Vellekoop M; Kraft M; Lendl B Anal Bioanal Chem; 2011 Jun; 400(8):2487-97. PubMed ID: 21369756 [TBL] [Abstract][Full Text] [Related]
4. Design, simulation and application of a new micromixing device for time resolved infrared spectroscopy of chemical reactions in solution. Hinsmann P; Frank J; Svasek P; Harasek M; Lendl B Lab Chip; 2001 Sep; 1(1):16-21. PubMed ID: 15100884 [TBL] [Abstract][Full Text] [Related]
5. Fast infrared chemical imaging with a quantum cascade laser. Yeh K; Kenkel S; Liu JN; Bhargava R Anal Chem; 2015 Jan; 87(1):485-93. PubMed ID: 25474546 [TBL] [Abstract][Full Text] [Related]
6. Towards biochemical reaction monitoring using FT-IR synchrotron radiation. Kaun N; Kulka S; Frank J; Schade U; Vellekoop MJ; Harasek M; Lendl B Analyst; 2006 Apr; 131(4):489-94. PubMed ID: 16568164 [TBL] [Abstract][Full Text] [Related]
7. Performance and application of a new planar array infrared spectrograph operating in the mid-infrared (2000-975 cm(-1)) fingerprint region. Pellerin C; Snively CM; Chase DB; Rabolt JF Appl Spectrosc; 2004 Jun; 58(6):639-46. PubMed ID: 15198813 [TBL] [Abstract][Full Text] [Related]
8. High throughput operando studies using Fourier transform infrared imaging and Raman spectroscopy. Li G; Hu D; Xia G; White JM; Zhang C Rev Sci Instrum; 2008 Jul; 79(7):074101. PubMed ID: 18681719 [TBL] [Abstract][Full Text] [Related]
9. Fourier transform infrared imaging of human hair with a high spatial resolution without the use of a synchrotron. Chan KL; Kazarian SG; Mavraki A; Williams DR Appl Spectrosc; 2005 Feb; 59(2):149-55. PubMed ID: 15720754 [TBL] [Abstract][Full Text] [Related]
10. Orthogonal projections to latent structures discriminant analysis modeling on in situ FT-IR spectral imaging of liver tissue for identifying sources of variability. Stenlund H; Gorzsás A; Persson P; Sundberg B; Trygg J Anal Chem; 2008 Sep; 80(18):6898-906. PubMed ID: 18714965 [TBL] [Abstract][Full Text] [Related]
11. Fourier transform infrared imaging spectroscopy of the diffusion process of D2O into polyamide 11. Wessel E; Vogel C; Siesler HW Appl Spectrosc; 2009 Jan; 63(1):1-5. PubMed ID: 19146711 [TBL] [Abstract][Full Text] [Related]
12. Secondary structure of proteins analyzed ex vivo in vascular wall in diabetic animals using FT-IR spectroscopy. Majzner K; Wrobel TP; Fedorowicz A; Chlopicki S; Baranska M Analyst; 2013 Nov; 138(24):7400-10. PubMed ID: 24179990 [TBL] [Abstract][Full Text] [Related]
13. Time-resolved step-scan infrared imaging system utilizing a linear array detector. Sugiyama H; Koshoubu J; Kashiwabara S; Nagoshi T; Larsen RA; Akao K Appl Spectrosc; 2008 Jan; 62(1):17-23. PubMed ID: 18230202 [TBL] [Abstract][Full Text] [Related]
14. Detection of trace materials with Fourier transform infrared spectroscopy using a multi-channel detector. Chan KL; Kazarian SG Analyst; 2006 Jan; 131(1):126-31. PubMed ID: 16365673 [TBL] [Abstract][Full Text] [Related]
15. Cell-specific chemotyping and multivariate imaging by combined FT-IR microspectroscopy and orthogonal projections to latent structures (OPLS) analysis reveals the chemical landscape of secondary xylem. Gorzsás A; Stenlund H; Persson P; Trygg J; Sundberg B Plant J; 2011 Jun; 66(5):903-14. PubMed ID: 21332846 [TBL] [Abstract][Full Text] [Related]
16. Fourier transform spectroscopic imaging using an infrared focal-plane array detector. Lewis EN; Treado PJ; Reeder RC; Story GM; Dowrey AE; Marcott C; Levin IW Anal Chem; 1995 Oct; 67(19):3377-81. PubMed ID: 8686889 [TBL] [Abstract][Full Text] [Related]
17. Infrared microspectroscopic imaging using a large radius germanium internal reflection element and a focal plane array detector. Patterson BM; Havrilla GJ; Marcott C; Story GM Appl Spectrosc; 2007 Nov; 61(11):1147-52. PubMed ID: 18028692 [TBL] [Abstract][Full Text] [Related]
18. Fourier transform infrared spectrochemical imaging: review of design and applications with a focal plane array and multiple beam synchrotron radiation source. Hirschmugl CJ; Gough KM Appl Spectrosc; 2012 May; 66(5):475-91. PubMed ID: 22524953 [TBL] [Abstract][Full Text] [Related]
20. Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector. Russo P; Mettivier G Med Phys; 2011 Apr; 38(4):2099-115. PubMed ID: 21626943 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]