These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 17144025)

  • 1. [Keypoints in formation of a mitral valve using an artificial chorda tendinae].
    Okabayashi H
    Kyobu Geka; 2006 Oct; 59(11):972-3. PubMed ID: 17144025
    [No Abstract]   [Full Text] [Related]  

  • 2. Artificial chordae for chordal replacement: commentary.
    Gillinov AM
    J Card Surg; 2008; 23(3):207-8. PubMed ID: 18435633
    [No Abstract]   [Full Text] [Related]  

  • 3. Pre-measured artificial chordae for mitral valve repair.
    Gillinov AM; Banbury MK
    Ann Thorac Surg; 2007 Dec; 84(6):2127-9. PubMed ID: 18036962
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Devised loop-in-loop technique in mitral valve repair.
    Tokunaga S; Yasuda S; Masuda M
    Asian Cardiovasc Thorac Ann; 2014 Nov; 22(9):1132-4. PubMed ID: 24887864
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Robotic mitral valve repair using polytetrafluoroethylene neochordal resuspension: the "known and unknown knowns".
    Suri RM; Burkhart HM
    Ann Thorac Surg; 2013 Nov; 96(5):1914-5. PubMed ID: 24182500
    [No Abstract]   [Full Text] [Related]  

  • 6. [Surgical treatment of mitral valve prolapse using the mitral apparatus to adjust proper length of artificial chordae].
    Yasui H; Tomita Y; Imoto H; Tomihaga T; Morita S; Toshima Y; Fukumura F
    Jpn J Thorac Cardiovasc Surg; 1998 Apr; 46 Suppl():147-8. PubMed ID: 9642824
    [No Abstract]   [Full Text] [Related]  

  • 7. Preoperative determination of artificial chordae length.
    Mandegar MH; Yousefnia MA; Roshanali F
    Ann Thorac Surg; 2007 Aug; 84(2):680-2. PubMed ID: 17643670
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Longitudinal plication of the posterior leaflet in myxomatous disease of the mitral valve.
    Calafiore AM; Di Mauro M; Actis-Dato G; Iacò AL; Centofanti P; Forsennati P; Patanè F; Di Gioacchino L
    Ann Thorac Surg; 2006 May; 81(5):1909-10. PubMed ID: 16631710
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Mitral valve repair with artificial chordal creation].
    Okamoto K; Kudo M; Yozu R
    Kyobu Geka; 2012 Apr; 65(4):291-5. PubMed ID: 22485032
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application and adjustment of artificial chordae to the mitral valve using an approach through the aortic valve.
    Prêtre R; Khatchatourov G; Kadner A; Genoni M
    Ann Thorac Surg; 2006 Aug; 82(2):761-2. PubMed ID: 16863816
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [A case report on mitral valve prolapse syndrome with rapid and extensive rupture of the chordae tendineae of the mitral valve (author's transl)].
    Shomura T; Takeuchi Y; Hirata A; Fukuyama M; Okamoto K; Miyamoto S; Nishiuchi S; Nakamura T; Yamaga T; Hata H; Tatemichi K; Yoshizumi M; Okumachi F; Takagi Y; Yanagihara K; Kato H; Yoshikawa J; Morimoto S
    Kokyu To Junkan; 1981 Jul; 29(7):785-90. PubMed ID: 7291748
    [No Abstract]   [Full Text] [Related]  

  • 12. A simple method of preparing artificial chordae for mitral valve repair.
    Tam R; Joshi P; Konstantinov IE
    J Thorac Cardiovasc Surg; 2006 Dec; 132(6):1486-7. PubMed ID: 17140991
    [No Abstract]   [Full Text] [Related]  

  • 13. Ruptured synthetic expanded polytetrafluoroethylene chordae tendinae.
    Butany J; Collins MJ; David TE
    Cardiovasc Pathol; 2004; 13(3):182-4. PubMed ID: 15081477
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel technique of utilizing artificial chordae for repair of mitral valve prolapse.
    Scorsin M; Al-Attar N; Lessana A
    J Thorac Cardiovasc Surg; 2007 Oct; 134(4):1072-3. PubMed ID: 17903545
    [No Abstract]   [Full Text] [Related]  

  • 15. Adjusting the length of Goretex artificial chordae.
    Radermecker MA
    Ann Thorac Surg; 2010 Jan; 89(1):344-5; author reply 345. PubMed ID: 20103288
    [No Abstract]   [Full Text] [Related]  

  • 16. Artificial chordae for mitral valve repair: mid-term clinical and echocardiographic results.
    Risteski PS; Aybek T; Dzemali O; Doss M; Scherer M; Dogan S; Moritz A
    Thorac Cardiovasc Surg; 2007 Jun; 55(4):239-44. PubMed ID: 17546554
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Adjusting the length of artificial polytetrafluoroethylene chordae in mitral valve repair by a single loop technique.
    Moorjani N; Viola N; Janusauskas V; Livesey S
    J Thorac Cardiovasc Surg; 2009 Dec; 138(6):1441-2. PubMed ID: 19660314
    [No Abstract]   [Full Text] [Related]  

  • 18. [An infant case of a rupture of chordae tendineae; report of a case].
    Uehara K; Yamanaka K; Iwakura A; Ueyama K; Matsumura M; Yoshimura S; Sugita T; Nishimura K
    Kyobu Geka; 2007 Dec; 60(13):1185-7. PubMed ID: 18078087
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A simple method to obtain the correct length of the artificial chordae in complex chordal replacement.
    Calafiore AM; Scandura S; Iacò AL; Contini M; Di Mauro M; Bivona A; Giordano G; Bosco P
    J Card Surg; 2008; 23(3):204-6. PubMed ID: 18435632
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Neo-chordae length adjustment in mitral valve repair.
    Cimen S; Ketenci B; Ozay B; Demirtas M
    Eur J Cardiothorac Surg; 2006 May; 29(5):843-4. PubMed ID: 16520045
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.