BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 17162516)

  • 1. Effects of fluid insert volume changes on socket pressures and shear stresses: case studies from two trans-tibial amputee subjects.
    Sanders JE; Jacobsen AK; Fergason JR
    Prosthet Orthot Int; 2006 Dec; 30(3):257-69. PubMed ID: 17162516
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of changes in cadence, prosthetic componentry, and time on interface pressures and shear stresses of three trans-tibial amputees.
    Sanders JE; Zachariah SG; Baker AB; Greve JM; Clinton C
    Clin Biomech (Bristol, Avon); 2000 Nov; 15(9):684-94. PubMed ID: 10946102
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of trans-tibial amputee suction and vacuum socket conditions.
    Board WJ; Street GM; Caspers C
    Prosthet Orthot Int; 2001 Dec; 25(3):202-9. PubMed ID: 11860094
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of alignment changes on stance phase pressures and shear stresses on transtibial amputees: measurements from 13 transducer sites.
    Sanders JE; Bell DM; Okumura RM; Dralle AJ
    IEEE Trans Rehabil Eng; 1998 Mar; 6(1):21-31. PubMed ID: 9535520
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Standing interface stresses as a predictor of walking interface stresses in the trans-tibial prosthesis.
    Zachariah SG; Sanders JE
    Prosthet Orthot Int; 2001 Apr; 25(1):34-40. PubMed ID: 11411003
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Walking in a vacuum-assisted socket shifts the stump fluid balance.
    Goswami J; Lynn R; Street G; Harlander M
    Prosthet Orthot Int; 2003 Aug; 27(2):107-13. PubMed ID: 14571940
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interface pressures and shear stresses: sagittal plane angular alignment effects in three trans-tibial amputee case studies.
    Sanders JE; Daly CH
    Prosthet Orthot Int; 1999 Apr; 23(1):21-9. PubMed ID: 10355640
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis.
    Zhang M; Turner-Smith AR; Tanner A; Roberts VC
    Med Eng Phys; 1998 Apr; 20(3):188-98. PubMed ID: 9690489
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical measurement of normal and shear stresses on a trans-tibial stump: characteristics of wave-form shapes during walking.
    Sanders JE; Daly CH; Burgess EM
    Prosthet Orthot Int; 1993 Apr; 17(1):38-48. PubMed ID: 8337099
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
    Lee VS; Solomonidis SE; Spence WD
    Proc Inst Mech Eng H; 1997; 211(2):167-80. PubMed ID: 9184457
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of heel lifting on transtibial amputee gait before and after treadmill walking: a case study.
    Yeung LF; Leung AK; Zhang M; Lee WC
    Prosthet Orthot Int; 2013 Aug; 37(4):317-23. PubMed ID: 23124990
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee wearing a hydrocast socket.
    Convery P; Buis AW
    Prosthet Orthot Int; 1999 Aug; 23(2):107-12. PubMed ID: 10493137
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of alignment on interface pressure for transtibial amputee during walking.
    Jia X; Suo S; Meng F; Wang R
    Disabil Rehabil Assist Technol; 2008 Nov; 3(6):339-43. PubMed ID: 19127605
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dynamic alignment using external socket reaction moments in trans-tibial amputees.
    Jonkergouw N; Prins MR; van der Wurff P; Gijsbers J; Houdijk H; Buis AWP
    Gait Posture; 2019 Feb; 68():122-129. PubMed ID: 30472524
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Changes in interface pressures and shear stresses over time on trans-tibial amputee subjects ambulating with prosthetic limbs: comparison of diurnal and six-month differences.
    Sanders JE; Zachariah SG; Jacobsen AK; Fergason JR
    J Biomech; 2005 Aug; 38(8):1566-73. PubMed ID: 15958212
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dynamic alignment of transtibial prostheses through visualization of socket reaction moments.
    Kobayashi T; Orendurff MS; Boone DA
    Prosthet Orthot Int; 2015 Dec; 39(6):512-6. PubMed ID: 25121726
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic foot.
    Wolf SI; Alimusaj M; Fradet L; Siegel J; Braatz F
    Clin Biomech (Bristol, Avon); 2009 Dec; 24(10):860-5. PubMed ID: 19744755
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Static and dynamic pressure prediction for prosthetic socket fitting assessment utilising an inverse problem approach.
    Sewell P; Noroozi S; Vinney J; Amali R; Andrews S
    Artif Intell Med; 2012 Jan; 54(1):29-41. PubMed ID: 21963113
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of lower limb prosthetic socket interface based on stress and motion measurements.
    Tang J; Jiang L; McGrath M; Bader D; Laszczak P; Moser D; Zahedi S
    Proc Inst Mech Eng H; 2022 Sep; 236(9):1349-1356. PubMed ID: 35821656
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of long-distance walking on socket-limb interface pressure, tactile sensitivity and subjective perceptions of trans-tibial amputees.
    Yeung LF; Leung AK; Zhang M; Lee WC
    Disabil Rehabil; 2013 Jun; 35(11):888-93. PubMed ID: 22992201
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.