BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 17169700)

  • 1. Investigating the nonlinear microbubble response to chirp encoded, multipulse sequences.
    Chetty K; Hajnal JV; Eckersley RJ
    Ultrasound Med Biol; 2006 Dec; 32(12):1887-95. PubMed ID: 17169700
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Amplitude-modulation chirp imaging for contrast detection.
    Li ML; Kuo YC; Yeh CK
    Ultrasound Med Biol; 2010 Sep; 36(9):1535-45. PubMed ID: 20800180
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microbubble contrast agent detection using binary coded pulses.
    Eckersley RJ; Tang MX; Chetty K; Hajnal JV
    Ultrasound Med Biol; 2007 Nov; 33(11):1787-95. PubMed ID: 17629609
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Chirp-encoded excitation for dual-frequency ultrasound tissue harmonic imaging.
    Shen CC; Lin CH
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Nov; 59(11):2420-30. PubMed ID: 23192805
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The feasibility of pulse compression by nonlinear effective bandwidth extension.
    Clement GT; Nomura H; Kamakura T
    J Acoust Soc Am; 2011 Oct; 130(4):1810-9. PubMed ID: 21973334
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of amplitude modulation on subharmonic imaging with chirp excitation.
    Harput S; Arif M; McLaughlan J; Cowell DM; Freear S
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Dec; 60(12):2532-44. PubMed ID: 24297019
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Observation of contrast agent response to chirp insonation with a simultaneous optical-acoustical system.
    Sun Y; Zhao S; Dayton PA; Ferrara KW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2006 Jun; 53(6):1130-7. PubMed ID: 16846145
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Contrast imaging with chirped excitation.
    Sun Y; Kruse DE; Ferrara KW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Mar; 54(3):520-9. PubMed ID: 17375821
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nonlinear pulse compression in pulse-inversion fundamental imaging.
    Cheng YC; Shen CC; Li PC
    Ultrason Imaging; 2007 Apr; 29(2):73-86. PubMed ID: 17679323
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Coded tissue harmonic imaging with nonlinear chirp signals.
    Song J; Chang JH; Song TK; Yoo Y
    Ultrasonics; 2011 May; 51(4):516-21. PubMed ID: 21216422
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ambient Pressure Evaluation Through Sub-Harmonic Response of Chirp-Sonicated Microbubbles.
    Liu S; Wu J; Gu Y; Guo X; Tu J; Xu D; Zhang D
    Ultrasound Med Biol; 2017 Jan; 43(1):332-340. PubMed ID: 27717516
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The response of phospholipid-encapsulated microbubbles to chirp-coded excitation: implications for high-frequency nonlinear imaging.
    Shekhar H; Doyley MM
    J Acoust Soc Am; 2013 May; 133(5):3145-58. PubMed ID: 23654417
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array.
    Novell A; Arena CB; Kasoji S; Dayton PA
    Phys Med Biol; 2015 Apr; 60(8):3111-27. PubMed ID: 25803232
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design of chirp excitation waveform for dual-frequency harmonic contrast detection.
    Shen CC; Chiu YY
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Oct; 56(10):2198-206. PubMed ID: 19942507
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bubble-based acoustic radiation force using chirp insonation to reduce standing wave effects.
    Erpelding TN; Hollman KW; O'Donnell M
    Ultrasound Med Biol; 2007 Feb; 33(2):263-9. PubMed ID: 17306697
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Enhancement of subharmonic emission from encapsulated microbubbles by using a chirp excitation technique.
    Zhang D; Gong Y; Gong X; Liu Z; Tan K; Zheng H
    Phys Med Biol; 2007 Sep; 52(18):5531-44. PubMed ID: 17804880
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Role of Microbubble Echo Phase Lag in Multipulse Contrast-Enhanced Ultrasound Imaging.
    Tremblay-Darveau C; Sheeran PS; Vu CK; Williams R; Zhang Z; Bruce M; Burns PN
    IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Aug; 65(8):1389-1401. PubMed ID: 29993575
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Adaptive Light Modulation for Improved Resolution and Efficiency in All-Optical Pulse-Echo Ultrasound.
    Alles EJ; Colchester RJ; Desjardins AE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Jan; 63(1):83-90. PubMed ID: 26552084
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Investigation of Non-linear Chirp Coding for Improved Second Harmonic Pulse Compression.
    Arif M; Ali MA; Shaikh MM; Freear S
    Ultrasound Med Biol; 2017 Aug; 43(8):1690-1702. PubMed ID: 28483580
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of chirp reversal power modulation sequence for contrast agent imaging.
    Novell A; Sennoga CA; Escoffre JM; Chaline J; Bouakaz A
    Phys Med Biol; 2014 Sep; 59(17):5101-17. PubMed ID: 25122547
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.