These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 17171457)

  • 21. Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.
    Siskey R; Ciccarelli L; Lui MK; Kurtz SM
    Clin Orthop Relat Res; 2016 Nov; 474(11):2428-2440. PubMed ID: 27677290
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Wear of surface engineered metal-on-metal hip prostheses.
    Fisher J; Hu XQ; Stewart TD; Williams S; Tipper JL; Ingham E; Stone MH; Davies C; Hatto P; Bolton J; Riley M; Hardaker C; Isaac GH; Berry G
    J Mater Sci Mater Med; 2004 Mar; 15(3):225-35. PubMed ID: 15334994
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up.
    Wang S; Zhang S; Zhao Y
    J Orthop Surg Res; 2013 Jul; 8():20. PubMed ID: 23835248
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions.
    Kovochich M; Fung ES; Donovan E; Unice KM; Paustenbach DJ; Finley BL
    J Biomed Mater Res B Appl Biomater; 2018 Apr; 106(3):986-996. PubMed ID: 28480531
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Same survival but higher rate of osteolysis for metal-on-metal Ultamet versus ceramic-on-ceramic in patients undergoing primary total hip arthroplasty after 8 years of follow-up.
    Higuchi Y; Seki T; Takegami Y; Komatsu D; Morita D; Ishiguro N
    Orthop Traumatol Surg Res; 2018 Dec; 104(8):1155-1161. PubMed ID: 30269967
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Hard bearing surfaces in total hip arthroplasty.
    Jazrawi LM; Kummer FJ; Di Cesare PE
    Am J Orthop (Belle Mead NJ); 1998 Apr; 27(4):283-92. PubMed ID: 9586727
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces.
    Yoon TR; Rowe SM; Jung ST; Seon KJ; Maloney WJ
    J Bone Joint Surg Am; 1998 Oct; 80(10):1459-68. PubMed ID: 9801214
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Long-term performance of ceramic and metal femoral heads on conventional polyethylene in young and active patients: a matched-pair analysis.
    Meftah M; Klingenstein GG; Yun RJ; Ranawat AS; Ranawat CS
    J Bone Joint Surg Am; 2013 Jul; 95(13):1193-7. PubMed ID: 23824387
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses.
    Brown C; Fisher J; Ingham E
    Proc Inst Mech Eng H; 2006 Feb; 220(2):355-69. PubMed ID: 16669401
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Isolation and morphological characterisation of UHMWPE wear debris generated in vitro.
    Affatato S; Fernandes B; Tucci A; Esposito L; Toni A
    Biomaterials; 2001 Sep; 22(17):2325-31. PubMed ID: 11511029
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Scanning Electron Microscopy and Energy-Dispersive X-Ray Spectroscopy as a Valuable Tool to Investigate the Ultra-High-Molecular-Weight Polyethylene Wear Mechanisms and Debris in Hip Implants.
    Schappo H; Gindri IM; Cubillos PO; Maru MM; Salmoria GV; Roesler CRM
    J Arthroplasty; 2018 Jan; 33(1):258-262. PubMed ID: 28844766
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The in vitro genotoxicity of orthopaedic ceramic (Al2O3) and metal (CoCr alloy) particles.
    Tsaousi A; Jones E; Case CP
    Mutat Res; 2010 Mar; 697(1-2):1-9. PubMed ID: 20139029
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Understanding the differences between the wear of metal-on-metal and ceramic-on-metal total hip replacements.
    Figueiredo-Pina CG; Yan Y; Neville A; Fisher J
    Proc Inst Mech Eng H; 2008 Apr; 222(3):285-96. PubMed ID: 18491698
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris.
    Howling GI; Ingham E; Sakoda H; Stewart TD; Fisher J; Antonarulrajah A; Appleyard S; Rand B
    J Mater Sci Mater Med; 2004 Jan; 15(1):91-8. PubMed ID: 15338596
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A Randomized Seven-Year Study on Performance of the Stemmed Metal M2a-Magnum and Ceramic C2a-Taper, and the Resurfacing ReCap Hip Implants.
    Borgwardt A; Borgwardt L; Zerahn B; Daugaard H; Borgwardt L; Ribel-Madsen S
    J Arthroplasty; 2018 May; 33(5):1412-1420. PubMed ID: 29276121
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Microseparation and stripe wear in alumina-on-alumina hip implants.
    Affatato S; Traina F; Toni A
    Int J Artif Organs; 2011 Jun; 34(6):506-12. PubMed ID: 21725932
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. I. Analysis of particle size and shape.
    Catelas I; Bobyn JD; Medley JB; Krygier JJ; Zukor DJ; Petit A; Huk OL
    J Biomed Mater Res; 2001 Jun; 55(3):320-9. PubMed ID: 11255185
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Friction of total hip replacements with different bearings and loading conditions.
    Brockett C; Williams S; Jin Z; Isaac G; Fisher J
    J Biomed Mater Res B Appl Biomater; 2007 May; 81(2):508-15. PubMed ID: 17041924
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Serum-cobalt levels with metal-on-metal bearings in the cement-free total hip arthroplasty results covering two years; prospective study.
    Weissinger M; Grübl A; Pöll G
    Acta Chir Orthop Traumatol Cech; 2011; 78(5):410-5. PubMed ID: 22094154
    [TBL] [Abstract][Full Text] [Related]  

  • 40. How do alternative bearing surfaces influence wear behavior?
    Clarke IC; Manley MT;
    J Am Acad Orthop Surg; 2008; 16 Suppl 1():S86-93. PubMed ID: 18612022
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.