These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
125 related articles for article (PubMed ID: 17171913)
1. Intraoperative stroke during carotid endarterectomy without a change in the spectral edge frequency of the compressed spectral array. Bowdle TA; Rooke GA; Kazmers A J Cardiothorac Anesth; 1988 Apr; 2(2):204-6. PubMed ID: 17171913 [No Abstract] [Full Text] [Related]
2. The role of monitoring the depth of anesthesia in a case of hereditary sensory and autonomic neuropathy (Riley Day syndrome). Adhikary SD; Korula PJ Paediatr Anaesth; 2007 Apr; 17(4):402-3; author reply 403. PubMed ID: 17359420 [No Abstract] [Full Text] [Related]
3. QEEG changes during carotid clamping in carotid endarterectomy: spectral edge frequency parameters and relative band power parameters. Laman DM; Wieneke GH; van Duijn H; Veldhuizen RJ; van Huffelen AC J Clin Neurophysiol; 2005 Aug; 22(4):244-52. PubMed ID: 16093896 [TBL] [Abstract][Full Text] [Related]
4. Intraoperative monitoring with somatosensory evoked potentials in carotid artery surgery--less reliable in patients with preoperative neurologic deficiency? Linstedt U; Maier C; Petry A Acta Anaesthesiol Scand; 1998 Jan; 42(1):13-6. PubMed ID: 9527736 [TBL] [Abstract][Full Text] [Related]
5. Detection of ischemic electroencephalography changes during carotid endarterectomy using synchronization likelihood analysis. Rijsdijk M; Ferrier C; Laman M; Kesecioglu J; Stam K; Slooter A J Neurosurg Anesthesiol; 2009 Oct; 21(4):302-6. PubMed ID: 19955892 [TBL] [Abstract][Full Text] [Related]
6. Carotid endarterectomy with routine electroencephalography and selective shunting. Schneider JR; Novak KE Semin Vasc Surg; 2004 Sep; 17(3):230-5. PubMed ID: 15449246 [TBL] [Abstract][Full Text] [Related]
7. Carotid endarterectomy without shunt: the role of cerebral metabolic protection. Melgar MA; Mariwalla N; Madhusudan H; Weinand M Neurol Res; 2005 Dec; 27(8):850-6. PubMed ID: 16354546 [TBL] [Abstract][Full Text] [Related]
8. The choice of anaesthetic for carotid endarterectomy: does it matter? Archer DP; Tang TK Can J Anaesth; 1995 Jul; 42(7):566-70. PubMed ID: 7553991 [No Abstract] [Full Text] [Related]
9. Association of intraoperative transcranial Doppler monitoring variables with stroke from carotid endarterectomy. Rabb CH Stroke; 2001 Mar; 32(3):812-3. PubMed ID: 11239208 [No Abstract] [Full Text] [Related]
10. Local anesthetic infiltration of the wound for supplemental postoperative pain management in a pediatric liver transplant patient. Kim TW; Chan CC Paediatr Anaesth; 2007 Jan; 17(1):87-8. PubMed ID: 17184441 [No Abstract] [Full Text] [Related]
11. Correlation of carotid artery stump pressure and neurologic changes during 474 carotid endarterectomies performed in awake patients. Calligaro KD; Dougherty MJ J Vasc Surg; 2005 Oct; 42(4):684-9. PubMed ID: 16242555 [TBL] [Abstract][Full Text] [Related]
12. The influence of the alpha2-adrenoceptor agonist, clonidine, on the EEG and on the MAC of isoflurane. El-Kerdawy HM; Zalingen EE; Bovill JG Eur J Anaesthesiol; 2000 Feb; 17(2):105-10. PubMed ID: 10758454 [TBL] [Abstract][Full Text] [Related]
13. Is Two Really Better Than One? Examining the Superiority of Dual Modality Neurophysiological Monitoring During Carotid Endarterectomy: A Meta-Analysis. Thiagarajan K; Cheng HL; Huang JE; Natarajan P; Crammond DJ; Balzer JR; Thirumala PD World Neurosurg; 2015 Dec; 84(6):1941-9.e1. PubMed ID: 26341440 [TBL] [Abstract][Full Text] [Related]
14. Haemodynamic instability and myocardial ischaemia during carotid endarterectomy: a comparison of propofol and isoflurane. Mutch WA; White IW; Donen N; Thomson IR; Rosenbloom M; Cheang M; West M Can J Anaesth; 1995 Jul; 42(7):577-87. PubMed ID: 7553993 [TBL] [Abstract][Full Text] [Related]
15. Awareness during laryngoscopy and intubation: quantitating incidence following induction of balanced anesthesia with etomidate and cisatracurium as detected with the isolated forearm technique. St Pierre M; Landsleitner B; Schwilden H; Schuettler J J Clin Anesth; 2000 Mar; 12(2):104-8. PubMed ID: 10818323 [TBL] [Abstract][Full Text] [Related]
16. Con: Routine shunting is not the optimal management of the patient undergoing carotid endarterectomy, but neither is neuromonitoring. Kalkman CJ J Cardiothorac Vasc Anesth; 2004 Jun; 18(3):381-3. PubMed ID: 15232822 [No Abstract] [Full Text] [Related]
17. Computer-derived density spectral array in detection of mild analog electroencephalographic ischemic pattern changes during carotid endarterectomy. Kearse LA; Martin D; McPeck K; Lopez-Bresnahan M J Neurosurg; 1993 Jun; 78(6):884-90. PubMed ID: 8487070 [TBL] [Abstract][Full Text] [Related]
18. Experience of 500 cases of neurophysiological monitoring in carotid endarterectomy. Stejskal L; Kramár F; Ostrý S; Benes V; Mohapl M; Limberk B Acta Neurochir (Wien); 2007; 149(7):681-8; discussion 689. PubMed ID: 17585364 [TBL] [Abstract][Full Text] [Related]
19. Spectral edge frequency of the electroencephalogram to monitor "depth" of anaesthesia with isoflurane or propofol. Schwender D; Daunderer M; Mulzer S; Klasing S; Finsterer U; Peter K Br J Anaesth; 1996 Aug; 77(2):179-84. PubMed ID: 8881621 [TBL] [Abstract][Full Text] [Related]
20. Prospective evaluation of electroencephalography, carotid artery stump pressure, and neurologic changes during 314 consecutive carotid endarterectomies performed in awake patients. Hans SS; Jareunpoon O J Vasc Surg; 2007 Mar; 45(3):511-5. PubMed ID: 17275248 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]