529 related articles for article (PubMed ID: 17174320)
1. Use of monolithic supports in proteomics technology.
Josic D; Clifton JG
J Chromatogr A; 2007 Mar; 1144(1):2-13. PubMed ID: 17174320
[TBL] [Abstract][Full Text] [Related]
2. A bifunctional monolithic column for combined protein preconcentration and digestion for high throughput proteomics research.
Zhang K; Wu S; Tang X; Kaiser NK; Bruce JE
J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Apr; 849(1-2):223-30. PubMed ID: 17150420
[TBL] [Abstract][Full Text] [Related]
3. More sensitive and quantitative proteomic measurements using very low flow rate porous silica monolithic LC columns with electrospray ionization-mass spectrometry.
Luo Q; Tang K; Yang F; Elias A; Shen Y; Moore RJ; Zhao R; Hixson KK; Rossie SS; Smith RD
J Proteome Res; 2006 May; 5(5):1091-7. PubMed ID: 16674098
[TBL] [Abstract][Full Text] [Related]
4. Preparation of 20-microm-i.d. silica-based monolithic columns and their performance for proteomics analyses.
Luo Q; Shen Y; Hixson KK; Zhao R; Yang F; Moore RJ; Mottaz HM; Smith RD
Anal Chem; 2005 Aug; 77(15):5028-35. PubMed ID: 16053318
[TBL] [Abstract][Full Text] [Related]
5. Identification of membrane proteins from mammalian cell/tissue using methanol-facilitated solubilization and tryptic digestion coupled with 2D-LC-MS/MS.
Blonder J; Chan KC; Issaq HJ; Veenstra TD
Nat Protoc; 2006; 1(6):2784-90. PubMed ID: 17406535
[TBL] [Abstract][Full Text] [Related]
6. Immobilized trypsin systems coupled on-line to separation methods: recent developments and analytical applications.
Massolini G; Calleri E
J Sep Sci; 2005 Jan; 28(1):7-21. PubMed ID: 15688626
[TBL] [Abstract][Full Text] [Related]
7. Isotope-labeling and affinity enrichment of phosphopeptides for proteomic analysis using liquid chromatography-tandem mass spectrometry.
Kota U; Chien KY; Goshe MB
Methods Mol Biol; 2009; 564():303-21. PubMed ID: 19544030
[TBL] [Abstract][Full Text] [Related]
8. MicroSPE-nanoLC-ESI-MS/MS using 10-microm-i.d. silica-based monolithic columns for proteomics.
Luo Q; Page JS; Tang K; Smith RD
Anal Chem; 2007 Jan; 79(2):540-5. PubMed ID: 17222018
[TBL] [Abstract][Full Text] [Related]
9. Novel monolithic enzymatic microreactor based on single-enzyme nanoparticles for highly efficient proteolysis and its application in multidimensional liquid chromatography.
Gao M; Zhang P; Hong G; Guan X; Yan G; Deng C; Zhang X
J Chromatogr A; 2009 Oct; 1216(44):7472-7. PubMed ID: 19481218
[TBL] [Abstract][Full Text] [Related]
10. Fully automatic separation and identification of phosphopeptides by continuous pH-gradient anion exchange online coupled with reversed-phase liquid chromatography mass spectrometry.
Dai J; Wang LS; Wu YB; Sheng QH; Wu JR; Shieh CH; Zeng R
J Proteome Res; 2009 Jan; 8(1):133-41. PubMed ID: 19053533
[TBL] [Abstract][Full Text] [Related]
11. Automated 20 kpsi RPLC-MS and MS/MS with chromatographic peak capacities of 1000-1500 and capabilities in proteomics and metabolomics.
Shen Y; Zhang R; Moore RJ; Kim J; Metz TO; Hixson KK; Zhao R; Livesay EA; Udseth HR; Smith RD
Anal Chem; 2005 May; 77(10):3090-100. PubMed ID: 15889897
[TBL] [Abstract][Full Text] [Related]
12. Off-line two-dimensional liquid chromatography with maximized sample loading to reversed-phase liquid chromatography-electrospray ionization tandem mass spectrometry for shotgun proteome analysis.
Wang N; Xie C; Young JB; Li L
Anal Chem; 2009 Feb; 81(3):1049-60. PubMed ID: 19178338
[TBL] [Abstract][Full Text] [Related]
13. New monolithic chromatographic supports for macromolecules immobilization: challenges and opportunities.
Calleri E; Ambrosini S; Temporini C; Massolini G
J Pharm Biomed Anal; 2012 Oct; 69():64-76. PubMed ID: 22386208
[TBL] [Abstract][Full Text] [Related]
14. Multicolumn separation platform for simultaneous depletion and prefractionation prior to 2-DE for facilitating in-depth serum proteomics profiling.
Jmeian Y; El Rassi Z
J Proteome Res; 2009 Oct; 8(10):4592-603. PubMed ID: 19670910
[TBL] [Abstract][Full Text] [Related]
15. Citrate boosts the performance of phosphopeptide analysis by UPLC-ESI-MS/MS.
Winter D; Seidler J; Ziv Y; Shiloh Y; Lehmann WD
J Proteome Res; 2009 Jan; 8(1):418-24. PubMed ID: 19053530
[TBL] [Abstract][Full Text] [Related]
16. Silica-based monoliths for rapid peptide screening by capillary liquid chromatography hyphenated with electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.
Leinweber FC; Schmid DG; Lubda D; Wiesmüller KH; Jung G; Tallarek U
Rapid Commun Mass Spectrom; 2003; 17(11):1180-8. PubMed ID: 12772274
[TBL] [Abstract][Full Text] [Related]
17. Isocratic solid phase extraction-liquid chromatography (SPE-LC) interfaced to high-performance tandem mass spectrometry for rapid protein identification.
Hørning OB; Kjeldsen F; Theodorsen S; Vorm O; Jensen ON
J Proteome Res; 2008 Aug; 7(8):3159-67. PubMed ID: 18578518
[TBL] [Abstract][Full Text] [Related]
18. Fe3+ immobilized metal affinity chromatography with silica monolithic capillary column for phosphoproteome analysis.
Feng S; Pan C; Jiang X; Xu S; Zhou H; Ye M; Zou H
Proteomics; 2007 Feb; 7(3):351-60. PubMed ID: 17177250
[TBL] [Abstract][Full Text] [Related]
19. Short monolithic columns for purification and fractionation of peptide samples for matrix-assisted laser desorption/ionization time-of-flight/time-of-flight mass spectrometry analysis in proteomics.
Moravcová D; Kahle V; Rehulková H; Chmelík J; Rehulka P
J Chromatogr A; 2009 Apr; 1216(17):3629-36. PubMed ID: 19217112
[TBL] [Abstract][Full Text] [Related]
20. Phosphopeptides enrichment using on-line two-dimensional strong cation exchange followed by reversed-phase liquid chromatography/mass spectrometry.
Lim KB; Kassel DB
Anal Biochem; 2006 Jul; 354(2):213-9. PubMed ID: 16750159
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]