404 related articles for article (PubMed ID: 17183123)
1. Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID.
Mohammadi M; Bezak E
Phys Med Biol; 2007 Jan; 52(1):N21-33. PubMed ID: 17183123
[TBL] [Abstract][Full Text] [Related]
2. Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.
Baker SJ; Budgell GJ; MacKay RI
Phys Med Biol; 2005 Apr; 50(7):1377-92. PubMed ID: 15798330
[TBL] [Abstract][Full Text] [Related]
3. Verification of dose delivery for a prostate sIMRT treatment using a SLIC-EPID.
Mohammadi M; Bezak E; Reich P
Appl Radiat Isot; 2008 Dec; 66(12):1930-8. PubMed ID: 18583141
[TBL] [Abstract][Full Text] [Related]
4. Dosimetric assessment of the field abutment region in head and neck treatments using a multileaf collimator.
Abdel-Hakim K; Nishimura T; Takaih M; Suzuki S; Sakahara H
Strahlenther Onkol; 2003 May; 179(5):312-9. PubMed ID: 12740658
[TBL] [Abstract][Full Text] [Related]
5. Two-dimensional transmitted dose measurements using a scanning liquid ionization chamber EPID.
Mohammadi M; Bezak E
Phys Med Biol; 2006 Jun; 51(11):2971-85. PubMed ID: 16723778
[TBL] [Abstract][Full Text] [Related]
6. An experimental investigation into the radiation field offset of a dynamic multileaf collimator.
Vial P; Oliver L; Greer PB; Baldock C
Phys Med Biol; 2006 Nov; 51(21):5517-38. PubMed ID: 17047267
[TBL] [Abstract][Full Text] [Related]
7. Analysis of the measurement precision of an amorphous silicon EPID used for MLC leaf position quality control and the long-term calibration stability of an optically controlled MLC.
Budgell GJ; Clarke MF
Phys Med Biol; 2008 Aug; 53(15):N297-306. PubMed ID: 18635894
[TBL] [Abstract][Full Text] [Related]
8. [Dosimetric characterization of a multileaf collimator].
Stasi M; Baiotto B; Palamara F; Gabriele P; Scielzo G
Radiol Med; 1999 May; 97(5):382-8. PubMed ID: 10432971
[TBL] [Abstract][Full Text] [Related]
9. Verification of a rounded leaf-end MLC model used in a radiotherapy treatment planning system.
Williams MJ; Metcalfe P
Phys Med Biol; 2006 Feb; 51(4):N65-78. PubMed ID: 16467576
[TBL] [Abstract][Full Text] [Related]
10. Siemens multileaf collimator characterization and quality assurance approaches for intensity-modulated radiotherapy.
Bayouth JE
Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S93-7. PubMed ID: 18406947
[TBL] [Abstract][Full Text] [Related]
11. Radiotherapy of prostate cancer with multileaf collimators (MLCs) optimization of the undulating dose distribution at the MLC edge.
Koelbl O; Schwab F; Bratengeier K; Vordermark D; Flentje M
Strahlenther Onkol; 2005 Feb; 181(2):108-12. PubMed ID: 15702299
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of MLC leaf positioning accuracy for static and dynamic IMRT treatments using DAVID in vivo dosimetric system.
Karagoz G; Zorlu F; Yeginer M; Yildiz D; Ozyigit G
J Appl Clin Med Phys; 2016 Mar; 17(2):14-23. PubMed ID: 27074451
[TBL] [Abstract][Full Text] [Related]
13. MLC leaf width impact on the clinical dose distribution: a Monte Carlo approach.
Leal A; Sánchez-Doblado F; Arráns R; Capote R; Lagares JI; Pavón EC; Roselló J
Int J Radiat Oncol Biol Phys; 2004 Aug; 59(5):1548-59. PubMed ID: 15275743
[TBL] [Abstract][Full Text] [Related]
14. The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields.
Van Esch A; Depuydt T; Huyskens DP
Radiother Oncol; 2004 May; 71(2):223-34. PubMed ID: 15110457
[TBL] [Abstract][Full Text] [Related]
15. Fast, daily linac verification for segmented IMRT using electronic portal imaging.
Vieira SC; Bolt RA; Dirkx ML; Visser AG; Heijmen BJ
Radiother Oncol; 2006 Jul; 80(1):86-92. PubMed ID: 16854483
[TBL] [Abstract][Full Text] [Related]
16. [Application of amorphous silicon electronic portal imaging device (a-Si EPID) to dosimetry quality assurance of radiation therapy].
Chen MW; Deng XW; Huang SM; Chen L; Kang DH
Ai Zheng; 2007 Nov; 26(11):1272-5. PubMed ID: 17991332
[TBL] [Abstract][Full Text] [Related]
17. An independent dose calculation algorithm for MLC-based radiotherapy including the spatial dependence of MLC transmission.
Lorenz F; Nalichowski A; Rosca F; Killoran J; Wenz F; Zygmanski P
Phys Med Biol; 2008 Feb; 53(3):557-73. PubMed ID: 18199902
[TBL] [Abstract][Full Text] [Related]
18. A novel method for patient exit and entrance dose prediction based on water equivalent path length measured with an amorphous silicon electronic portal imaging device.
Kavuma A; Glegg M; Metwaly M; Currie G; Elliott A
Phys Med Biol; 2010 Jan; 55(2):435-52. PubMed ID: 20019398
[TBL] [Abstract][Full Text] [Related]
19. Quantitative measurement of MLC leaf displacements using an electronic portal image device.
Yang Y; Xing L
Phys Med Biol; 2004 Apr; 49(8):1521-33. PubMed ID: 15152689
[TBL] [Abstract][Full Text] [Related]
20. An oscillating sweeping gap test for VMAT quality assurance.
Bhagwat MS; Han Z; Ng SK; Zygmanski P
Phys Med Biol; 2010 Sep; 55(17):5029-44. PubMed ID: 20702923
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]