  • 1. Inappropriate shock: a failure of SVT discriminators in a dual chamber ICD?
    Al-Ahmad A; Tsiperfal A; Hsia HH; Wang PJ
    Pacing Clin Electrophysiol; 2006 Dec; 29(12):1413-5. PubMed ID: 17201851
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Therapeutic strategies in inappropriate ICD therapy].
    Klein G; Korte T
    Herz; 2005 Nov; 30(7):619-24. PubMed ID: 16333588
    [TBL] [Abstract][Full Text] [Related]  

  • 3. ICD proarrhythmia as a consequence of an interaction with an algorithm to prevent atrial arrhythmias.
    Martínez-Sánchez J; García-Alberola A; Sánchez-Muñoz JJ; Peñafiel-Verdú P; Giner-Caro JA; Valdés-Chávarri M
    Pacing Clin Electrophysiol; 2009 Aug; 32(8):1096-8. PubMed ID: 19659632
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Shocking truths about implantable cardioverter defibrillator monitoring zones.
    Mansour F; Thibault B; Dubuc M; Guerra PG; Macle L; Brugada R; Roy D; Talajic M; Khairy P
    Pacing Clin Electrophysiol; 2007 Sep; 30(9):1146-8. PubMed ID: 17725760
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improving SVT discrimination in single-chamber ICDs: a new electrogram morphology-based algorithm.
    Klein GJ; Gillberg JM; Tang A; Inbar S; Sharma A; Unterberg-Buchwald C; Dorian P; Moore H; Duru F; Rooney E; Becker D; Schaaf K; Benditt D;
    J Cardiovasc Electrophysiol; 2006 Dec; 17(12):1310-9. PubMed ID: 17096661
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Inappropriate implantable cardiac defibrillator shock due to couplet premature ventricular contractions.
    Wongcharoen W; Benjanuwattra T; Pongprot Y; Rachakhom C; Phrommintikul A
    Pacing Clin Electrophysiol; 2008 May; 31(5):609-12. PubMed ID: 18439177
    [No Abstract]   [Full Text] [Related]  

  • 7. Inappropriate shocks or inappropriate programming? A review of Guidant's reconfirmation algorithm.
    Mansour F; Guash E; Berruezo A; Brugada J; Tolosana JM; Mont L
    Europace; 2009 Aug; 11(8):1120-2. PubMed ID: 19443435
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis: the detect supraventricular tachycardia study.
    Friedman PA; McClelland RL; Bamlet WR; Acosta H; Kessler D; Munger TM; Kavesh NG; Wood M; Daoud E; Massumi A; Schuger C; Shorofsky S; Wilkoff B; Glikson M
    Circulation; 2006 Jun; 113(25):2871-9. PubMed ID: 16769912
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact.
    Daubert JP; Zareba W; Cannom DS; McNitt S; Rosero SZ; Wang P; Schuger C; Steinberg JS; Higgins SL; Wilber DJ; Klein H; Andrews ML; Hall WJ; Moss AJ;
    J Am Coll Cardiol; 2008 Apr; 51(14):1357-65. PubMed ID: 18387436
    [TBL] [Abstract][Full Text] [Related]  

  • 10. SVT discrimination algorithms significantly reduce the rate of inappropriate therapy in the setting of modern-day delayed high-rate detection programming.
    Cheng A; Auricchio A; Schloss EJ; Kurita T; Sterns LD; Gerritse B; Brown ML; Fagan DH; Lexcen DR; Ellenbogen KA
    J Cardiovasc Electrophysiol; 2019 Dec; 30(12):2877-2884. PubMed ID: 31646695
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Arrhythmia detection in single- and dual-chamber implantable cardioverter defibrillators: the more leads, the better?
    Francia P; Balla C; Uccellini A; Cappato R
    J Cardiovasc Electrophysiol; 2009 Sep; 20(9):1077-82. PubMed ID: 19500231
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Single and inappropriate shock delivered out of tachycardia: device dysfunction?
    Fontenla A; Carrero D; Salguero R; López-Gil M; De Riva M; Arribas F
    Pacing Clin Electrophysiol; 2012 Jul; 35(7):884-6. PubMed ID: 22248372
    [No Abstract]   [Full Text] [Related]  

  • 13. Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device.
    Francisco GM; Sharma S; Dougherty AH; Kantharia BK
    Cardiol J; 2009; 16(5):473-6. PubMed ID: 19753529
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Non-determinable defibrillation threshold and inefficacy of implantable cardioverter/defibrillator shocks due to defective connections of the defibrillator lead terminals in the device header port.
    Maagh P; Trappe HJ; Meissner A
    Europace; 2007 Dec; 9(12):1161-2. PubMed ID: 17913694
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Apparent inappropriate shocks from an implantable cardioverter defibrillator:
    Moore DR; Kok LC; Vijayaraman P
    J Cardiovasc Electrophysiol; 2004 Jan; 15(1):116-7. PubMed ID: 15028086
    [No Abstract]   [Full Text] [Related]  

  • 16. Atrial fibrillation in patients with implantable defibrillators.
    Sakhuja R; Shah AJ; Keebler M; Thakur RK
    Cardiol Clin; 2009 Feb; 27(1):151-61, ix-x. PubMed ID: 19111771
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study.
    Wilkoff BL; Williamson BD; Stern RS; Moore SL; Lu F; Lee SW; Birgersdotter-Green UM; Wathen MS; Van Gelder IC; Heubner BM; Brown ML; Holloman KK;
    J Am Coll Cardiol; 2008 Aug; 52(7):541-50. PubMed ID: 18687248
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Combining shock reduction strategies to enhance ICD therapy: a role for computer modeling.
    Volosin KJ; Exner DV; Wathen MS; Sherfesee L; Scinicariello AP; Gillberg JM
    J Cardiovasc Electrophysiol; 2011 Mar; 22(3):280-9. PubMed ID: 20958831
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contribution of morphology discrimination algorithm for improving rhythm discrimination in slow and fast ventricular tachycardia zones in dual-chamber implantable cardioverter-defibrillators.
    Boriani G; Occhetta E; Cesario S; Grossi S; Marconi M; Speca G; Silvestri P; Biffi M; Bortnik M; Martignani C; Branzi A
    Europace; 2008 Aug; 10(8):918-25. PubMed ID: 18541620
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Programming ICDs in the Modern Era beyond Out-of-the Box Settings.
    Mansour F; Khairy P
    Pacing Clin Electrophysiol; 2011 Apr; 34(4):506-20. PubMed ID: 21303392
    [TBL] [Abstract][Full Text] [Related]  