These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 17202622)

  • 1. Two-dimensional multi-level strain estimation for discontinuous tissue.
    Shi H; Varghese T
    Phys Med Biol; 2007 Jan; 52(2):389-401. PubMed ID: 17202622
    [TBL] [Abstract][Full Text] [Related]  

  • 2. MUlti-Dimensional Spline-Based Estimator (MUSE) for motion estimation: algorithm development and initial results.
    Viola F; Coe RL; Owen K; Guenther DA; Walker WF
    Ann Biomed Eng; 2008 Dec; 36(12):1942-60. PubMed ID: 18807190
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simulation of ultrasound radio-frequency signals in deformed tissue for validation of 2D motion estimation with sub-sample accuracy.
    Goksel O; Zahiri-Azar R; Salcudean SE
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():2159-62. PubMed ID: 18002416
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A motion estimation refinement framework for real-time tissue axial strain estimation with freehand ultrasound.
    Zhou Y; Zheng YP
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Sep; 57(9):1943-51. PubMed ID: 20875984
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance evaluation of methods for two-dimensional displacement and strain estimation using ultrasound radio frequency data.
    Lopata RG; Nillesen MM; Hansen HH; Gerrits IH; Thijssen JM; de Korte CL
    Ultrasound Med Biol; 2009 May; 35(5):796-812. PubMed ID: 19282094
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Phase-sensitive lateral motion estimator for measurement of artery-wall displacement--phantom study.
    Hasegawa H; Kanai H
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Nov; 56(11):2450-62. PubMed ID: 19942531
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multi-frame elastography using a handheld force-controlled ultrasound probe.
    Kuzmin A; Zakrzewski AM; Anthony BW; Lempitsky V
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Aug; 62(8):1486-500. PubMed ID: 26276958
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Large displacement optical flow: descriptor matching in variational motion estimation.
    Brox T; Malik J
    IEEE Trans Pattern Anal Mach Intell; 2011 Mar; 33(3):500-13. PubMed ID: 20714020
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noninvasive two-dimensional strain imaging of arteries: validation in phantoms and preliminary experience in carotid arteries in vivo.
    Ribbers H; Lopata RG; Holewijn S; Pasterkamp G; Blankensteijn JD; de Korte CL
    Ultrasound Med Biol; 2007 Apr; 33(4):530-40. PubMed ID: 17280769
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improvement of elastographic displacement estimation using a two-step cross-correlation method.
    Chen H; Shi H; Varghese T
    Ultrasound Med Biol; 2007 Jan; 33(1):48-56. PubMed ID: 17189046
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sub-sample displacement estimation from digitized ultrasound RF signals using multi-dimensional polynomial fitting of the cross-correlation function.
    Zahiri Azar R; Goksel O; Salcudean SE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Nov; 57(11):2403-20. PubMed ID: 21041129
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Deformable image registration by combining uncertainty estimates from supervoxel belief propagation.
    Heinrich MP; Simpson IJ; Papież BW; Brady SM; Schnabel JA
    Med Image Anal; 2016 Jan; 27():57-71. PubMed ID: 26545720
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An adaptive displacement estimation algorithm for improved reconstruction of thermal strain.
    Ding X; Dutta D; Mahmoud AM; Tillman B; Leers SA; Kim K
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Jan; 62(1):138-51. PubMed ID: 25585398
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measuring submicrometer displacement vectors using high-frame-rate ultrasound imaging.
    Kruizinga P; Mastik F; Bosch JG; de Jong N; van der Steen AF; van Soest G
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Oct; 62(10):1733-44. PubMed ID: 26470036
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Precision estimation and imaging of normal and shear components of the 3D strain tensor in elastography.
    Konofagou EE; Ophir J
    Phys Med Biol; 2000 Jun; 45(6):1553-63. PubMed ID: 10870710
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3D dynamic model of healthy and pathologic arteries for ultrasound technique evaluation.
    Balocco S; Basset O; Azencot J; Tortoli P; Cachard C
    Med Phys; 2008 Dec; 35(12):5440-50. PubMed ID: 19175104
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental three dimensional strain estimation from ultrasonic sectorial data.
    Said G; Basset O; Mari JM; Cachard C; Brusseau E; Vray D
    Ultrasonics; 2006 Dec; 44 Suppl 1():e189-93. PubMed ID: 16870223
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 2-D locally regularized tissue strain estimation from radio-frequency ultrasound images: theoretical developments and results on experimental data.
    Brusseau E; Kybic J; Deprez JF; Basset O
    IEEE Trans Med Imaging; 2008 Feb; 27(2):145-60. PubMed ID: 18334437
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving IVUS palpography by incorporation of motion compensation based on block matching and optical flow.
    Danilouchkine MG; Mastik F; van der Steen AF
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Nov; 55(11):2392-404. PubMed ID: 19049919
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Towards pointwise motion tracking in echocardiographic image sequences--comparing the reliability of different features for speckle tracking.
    Yu W; Yan P; Sinusas AJ; Thiele K; Duncan JS
    Med Image Anal; 2006 Aug; 10(4):495-508. PubMed ID: 16574465
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.