These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 1721207)

  • 1. Biomagnetic noninvasive localization of accessory pathways in Wolff-Parkinson-White syndrome.
    Weismüller P; Abraham-Fuchs K; Schneider S; Richter P; Kochs M; Edrich J; Hombach V
    Pacing Clin Electrophysiol; 1991 Nov; 14(11 Pt 2):1961-5. PubMed ID: 1721207
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Magnetocardiographic non-invasive localization of accessory pathways in the Wolff-Parkinson-White syndrome by a multichannel system.
    Weismüller P; Abraham-Fuchs K; Schneider S; Richter P; Kochs M; Hombach V
    Eur Heart J; 1992 May; 13(5):616-22. PubMed ID: 1618202
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Magnetocardiographic localization of an accessory pathway in patients with WPW syndrome].
    Nomura M; Watanabe K; Katayama M; Takeuchi A; Ishihara S; Kiyoshige K; Fujimoto T; Fujino K; Nakaya Y; Mori H
    J Cardiol; 1990; 20(1):227-39. PubMed ID: 2093756
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Magnetocardiography: clinical investigations with a biomagnetic multichannel system.
    Achenbach ST; Moshage W
    Physiol Meas; 1993 Nov; 14 Suppl 4A():A61-8. PubMed ID: 8274987
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Non-invasive magnetocardiographic localization of ventricular pre-excitation in the Wolff-Parkinson-White syndrome using a realistic torso model.
    Nenonen J; Mäkijärvi M; Toivonen L; Forsman K; Leiniö M; Montonen J; Järvinen A; Keto P; Hekali P; Katila T
    Eur Heart J; 1993 Feb; 14(2):168-74. PubMed ID: 8449192
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Localization of accessory pathways in Wolff-Parkinson-White syndrome by high-resolution magnetocardiographic mapping.
    Mäkijärvi M; Nenonen J; Leiniö M; Montonen J; Toivonen L; Nieminen MS; Katila T; Siltanen P
    J Electrocardiol; 1992 Apr; 25(2):143-55. PubMed ID: 1522398
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetocardiographic localization of ventricular pre-excitation in a child with a congenital heart defect.
    Nenonen J; Rovamo L; Toivonen L; Ilmoniemi R; Järvinen A; Leiniö M; Montonen J; Nisula L
    Pediatr Cardiol; 1995; 16(1):33-5. PubMed ID: 7753700
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Noninvasive localization of accessory pathways by magnetocardiographic imaging.
    Nomura M; Nakaya Y; Saito K; Kishi F; Watatsuki T; Miyoshi H; Nishikado A; Bando S; Ito S; Nishitani H
    Clin Cardiol; 1994 May; 17(5):239-44. PubMed ID: 8004837
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical magnetocardiography: experience with a biomagnetic multichannel system.
    Moshage W; Achenbach S; Weikl A; Göhl K; Bachmann K; Abraham-Fuchs K; Härer W; Schneider S
    Int J Card Imaging; 1991; 7(3-4):217-23. PubMed ID: 1726471
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Noninvasive study of ventricular preexcitation using multichannel magnetocardiography.
    Fenici R; Brisinda D; Nenonen J; Fenici P
    Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):431-5. PubMed ID: 12687860
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Magnetocardiographic localization of the origin of ventricular ectopic beats.
    Oeff M; Burghoff M
    Pacing Clin Electrophysiol; 1994 Mar; 17(3 Pt 2):517-22. PubMed ID: 7513881
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Magnetocardiographic localization of arrhythmia substrates: a methodology study with accessory pathway ablation as reference.
    Agren PL; Göranson H; Hindmarsh T; Knutsson E; Mohlkert D; Rosenqvist M; Bergfeldt L
    IEEE Trans Med Imaging; 1998 Jun; 17(3):479-85. PubMed ID: 9735912
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Concordance of distinguishing electrocardiographic features during sinus rhythm with the location of accessory pathways in the Wolff-Parkinson-White syndrome.
    Lindsay BD; Crossen KJ; Cain ME
    Am J Cardiol; 1987 May; 59(12):1093-102. PubMed ID: 3578049
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Localization of ectopic ventricular depolarization by ISPECT-radionuclide ventriculography and by magnetocardiography. ISPECT and MCG for ectopic mapping.
    Hombach V; Kochs M; Weismüller P; Clausen M; Henze E; Richter P; Höher M; Peper A; Eggeling T; Adam WE
    Int J Card Imaging; 1991; 7(3-4):225-35. PubMed ID: 1820403
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Classifying cases of fetal Wolff-Parkinson-White syndrome by estimating the accessory pathway from fetal magnetocardiograms.
    Kandori A; Hosono T; Chiba Y; Shinto M; Miyashita S; Murakami M; Miyashita T; Ogata K; Tsukada K
    Med Biol Eng Comput; 2003 Jan; 41(1):33-9. PubMed ID: 12572745
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Localization of accessory pathways in the Wolff-Parkinson-White syndrome.
    Szabo TS; Klein GJ; Guiraudon GM; Yee R; Sharma AD
    Pacing Clin Electrophysiol; 1989 Oct; 12(10):1691-705. PubMed ID: 2477825
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Magnetocardiographic functional localization using a current dipole in a realistic torso.
    Nenonen J; Purcell CJ; Horacek BM; Stroink G; Katila T
    IEEE Trans Biomed Eng; 1991 Jul; 38(7):658-64. PubMed ID: 1879858
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Localization of the accessory pathways using surface ECG in Wolff-Parkinson-White syndrome].
    Di Biase M; Tritto M; Pitzalis MV; Favale S; Rizzon P
    Cardiologia; 1991 Aug; 36(8 Suppl):71-4. PubMed ID: 1817774
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Magnetocardiographic functional localization using current multipole models.
    Nenonen J; Katila T; Leiniö M; Montonen J; Mäkijärvi M; Siltanen P
    IEEE Trans Biomed Eng; 1991 Jul; 38(7):648-57. PubMed ID: 1879857
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the non-invasive localization accuracy of cardiac arrhythmias attainable by multichannel magnetocardiography (MCG).
    Moshage W; Achenbach S; Göhl K; Bachmann K
    Int J Card Imaging; 1996 Mar; 12(1):47-59. PubMed ID: 8847454
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.