275 related articles for article (PubMed ID: 17224004)
1. Spurious counts and spurious results on haematology analysers: a review. Part I: platelets.
Zandecki M; Genevieve F; Gerard J; Godon A
Int J Lab Hematol; 2007 Feb; 29(1):4-20. PubMed ID: 17224004
[TBL] [Abstract][Full Text] [Related]
2. Spurious counts and spurious results on haematology analysers: a review. Part II: white blood cells, red blood cells, haemoglobin, red cell indices and reticulocytes.
Zandecki M; Genevieve F; Gerard J; Godon A
Int J Lab Hematol; 2007 Feb; 29(1):21-41. PubMed ID: 17224005
[TBL] [Abstract][Full Text] [Related]
3. [Automated hematology analysers and spurious counts. Part 1. Platelets].
Tessier-Marteau A; Geneviève F; Godon A; Macchi L; Zandecki M
Ann Biol Clin (Paris); 2010; 68(4):393-407. PubMed ID: 20650734
[TBL] [Abstract][Full Text] [Related]
4. [Automated hematology analysers and spurious counts Part 2. Leukocyte count and differential].
Geneviève F; Godon A; Marteau-Tessier A; Zandecki M
Ann Biol Clin (Paris); 2012; 70(2):141-54. PubMed ID: 22484525
[TBL] [Abstract][Full Text] [Related]
5. [Automated hematology analysers and spurious counts Part 3. Haemoglobin, red blood cells, cell count and indices, reticulocytes].
Godon A; Genevieve F; Marteau-Tessier A; Zandecki M
Ann Biol Clin (Paris); 2012; 70(2):155-68. PubMed ID: 22484526
[TBL] [Abstract][Full Text] [Related]
6. Accuracy of platelet counting haematology analysers in severe thrombocytopenia and potential impact on platelet transfusion.
Segal HC; Briggs C; Kunka S; Casbard A; Harrison P; Machin SJ; Murphy MF
Br J Haematol; 2005 Feb; 128(4):520-5. PubMed ID: 15686462
[TBL] [Abstract][Full Text] [Related]
7. [Reliability of low platelet counts--comparison of microscopic counts with automated hematology analyzer XE-2100].
Orito M; Shibayama M; Yoshida T; Takami A; Asakura H; Fujita S; Nakao S
Rinsho Byori; 2005 Sep; 53(9):793-801. PubMed ID: 16235831
[TBL] [Abstract][Full Text] [Related]
8. Inappropriate platelet transfusion in a patient with ethylenediamine tetra- acetic acid (EDTA)--induced pseudothrombocytopenia.
Kakkar N; Garg G
Indian J Pathol Microbiol; 2006 Jan; 49(1):29-31. PubMed ID: 16625970
[TBL] [Abstract][Full Text] [Related]
9. [EDTA-dependent pseudothrombocytopenia: clinical aspects and laboratory tests].
Saigo K; Sakota Y; Masuda Y
Rinsho Byori; 2005 Jul; 53(7):646-53. PubMed ID: 16104534
[TBL] [Abstract][Full Text] [Related]
10. Problems with platelet counting in thrombocytopenia. A rapid manual method to measure low platelet counts.
Sutor AH; Grohmann A; Kaufmehl K; Wündisch T
Semin Thromb Hemost; 2001 Jun; 27(3):237-43. PubMed ID: 11446657
[TBL] [Abstract][Full Text] [Related]
11. [A marginal zone-B cell lymphoma revealed by platelet satellitism and lympho-agglutination phenomenon around atypical lymphocytes].
Debourgogne A; Latger-Cannard V; Montagne K; Plénat F; Lecompte T
Ann Biol Clin (Paris); 2007; 65(3):287-90. PubMed ID: 17502302
[TBL] [Abstract][Full Text] [Related]
12. [Diagnostic performance of graphical anomalies in the detection of large platelets and platelet clumps].
Sassi M; Dibej W; Abdi B; Abderrazak F; Hassine M; Babba H
Pathol Biol (Paris); 2015 Dec; 63(6):248-51. PubMed ID: 26524955
[TBL] [Abstract][Full Text] [Related]
13. [Platelet satellitism].
Kasprzycka E; Zak J; Ratomski K; Wysocka J; Hryniewicz K
Wiad Lek; 2006; 59(7-8):557-9. PubMed ID: 17209359
[TBL] [Abstract][Full Text] [Related]
14. Reticulated platelet counts correlate with treatment response in patients with idiopathic thrombocytopenic purpura and help identify the complex causes of thrombocytopenia in patients after allogeneic hematopoietic stem cell transplantation.
Thomas-Kaskel AK; Mattern D; Köhler G; Finke J; Behringer D
Cytometry B Clin Cytom; 2007 Jul; 72(4):241-8. PubMed ID: 17266149
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of the coulter LH 750 haematology analyzer compared with flow cytometry as the reference method for WBC, platelet and nucleated RBC count.
Igout J; Fretigny M; Vasse M; Callat MP; Silva M; Willemont L; Gelle M; Lenormand B
Clin Lab Haematol; 2004 Feb; 26(1):1-7. PubMed ID: 14738430
[TBL] [Abstract][Full Text] [Related]
16. The Haematology Analyser SF-3000: performance of the automated white blood cell differential count in comparison to the Haematology Analyser NE-1500.
Korninger L; Mustafa G; Schwarzinger I
Clin Lab Haematol; 1998 Apr; 20(2):81-6. PubMed ID: 9681217
[TBL] [Abstract][Full Text] [Related]
17. Platelet large cell ratio in the differential diagnosis of abnormal platelet counts.
Babu E; Basu D
Indian J Pathol Microbiol; 2004 Apr; 47(2):202-5. PubMed ID: 16295468
[TBL] [Abstract][Full Text] [Related]
18. [Four cases of pseudothrombocytopenia due to platelet cold agglutinins].
Kurata Y; Hayashi S; Jouzaki K; Konishi I; Kashiwagi H; Tomiyama Y
Rinsho Ketsueki; 2006 Aug; 47(8):781-6. PubMed ID: 16986719
[TBL] [Abstract][Full Text] [Related]
19. Comparison of platelet clumping and complete blood count results with Sysmex XT-2000iV in feline blood sampled on EDTA or EDTA plus CTAD (citrate, theophylline, adenosine and dipyridamole).
Granat F; Geffré A; Braun JP; Trumel C
J Feline Med Surg; 2011 Dec; 13(12):953-8. PubMed ID: 22079363
[TBL] [Abstract][Full Text] [Related]
20. Feline platelet counting with prostaglandin E1 on the Sysmex XT-2000iV.
Tvedten H; Johansson P
Vet Clin Pathol; 2010 Jun; 39(2):190-2. PubMed ID: 20059753
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]