552 related articles for article (PubMed ID: 17228114)
1. Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation.
Yang Y; Schreibmann E; Li T; Wang C; Xing L
Phys Med Biol; 2007 Feb; 52(3):685-705. PubMed ID: 17228114
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of on-board kV cone beam computed tomography-based dose calculation with deformable image registration using Hounsfield unit modifications.
Onozato Y; Kadoya N; Fujita Y; Arai K; Dobashi S; Takeda K; Kishi K; Umezawa R; Matsushita H; Jingu K
Int J Radiat Oncol Biol Phys; 2014 Jun; 89(2):416-23. PubMed ID: 24685445
[TBL] [Abstract][Full Text] [Related]
3. Validation of a deformable image registration technique for cone beam CT-based dose verification.
Moteabbed M; Sharp GC; Wang Y; Trofimov A; Efstathiou JA; Lu HM
Med Phys; 2015 Jan; 42(1):196-205. PubMed ID: 25563260
[TBL] [Abstract][Full Text] [Related]
4. Correction for 'artificial' electron disequilibrium due to cone-beam CT density errors: implications for on-line adaptive stereotactic body radiation therapy of lung.
Disher B; Hajdok G; Wang A; Craig J; Gaede S; Battista JJ
Phys Med Biol; 2013 Jun; 58(12):4157-74. PubMed ID: 23689060
[TBL] [Abstract][Full Text] [Related]
5. Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning.
Yoo S; Yin FF
Int J Radiat Oncol Biol Phys; 2006 Dec; 66(5):1553-61. PubMed ID: 17056197
[TBL] [Abstract][Full Text] [Related]
6. Assessment of image quality and dose calculation accuracy on kV CBCT, MV CBCT, and MV CT images for urgent palliative radiotherapy treatments.
Held M; Cremers F; Sneed PK; Braunstein S; Fogh SE; Nakamura J; Barani I; Perez-Andujar A; Pouliot J; Morin O
J Appl Clin Med Phys; 2016 Mar; 17(2):279-290. PubMed ID: 27074487
[TBL] [Abstract][Full Text] [Related]
7. Dose calculation on kV cone beam CT images: an investigation of the Hu-density conversion stability and dose accuracy using the site-specific calibration.
Rong Y; Smilowitz J; Tewatia D; Tomé WA; Paliwal B
Med Dosim; 2010; 35(3):195-207. PubMed ID: 19931031
[TBL] [Abstract][Full Text] [Related]
8. A new strategy for online adaptive prostate radiotherapy based on cone-beam CT.
Boggula R; Lorenz F; Abo-Madyan Y; Lohr F; Wolff D; Boda-Heggemann J; Hesser J; Wenz F; Wertz H
Z Med Phys; 2009; 19(4):264-76. PubMed ID: 19962084
[TBL] [Abstract][Full Text] [Related]
9. Technical note: Characterization of novel iterative reconstructed cone beam CT images for dose tracking and adaptive radiotherapy on L-shape linacs.
Lim R; Penoncello GP; Hobbis D; Harrington DP; Rong Y
Med Phys; 2022 Dec; 49(12):7715-7732. PubMed ID: 36031929
[TBL] [Abstract][Full Text] [Related]
10. Dual-energy imaging method to improve the image quality and the accuracy of dose calculation for cone-beam computed tomography.
Men K; Dai J; Chen X; Li M; Zhang K; Huang P
Phys Med; 2017 Apr; 36():110-118. PubMed ID: 28410679
[TBL] [Abstract][Full Text] [Related]
11. The impact of CBCT reconstruction and calibration for radiotherapy planning in the head and neck region - a phantom study.
Elstrøm UV; Olsen SR; Muren LP; Petersen JB; Grau C
Acta Oncol; 2014 Aug; 53(8):1114-24. PubMed ID: 24975372
[TBL] [Abstract][Full Text] [Related]
12. Investigation into image quality and dose for different patient geometries with multiple cone-beam CT systems.
Gardner SJ; Studenski MT; Giaddui T; Cui Y; Galvin J; Yu Y; Xiao Y
Med Phys; 2014 Mar; 41(3):031908. PubMed ID: 24593726
[TBL] [Abstract][Full Text] [Related]
13. Dose calculation accuracy of different image value to density tables for cone-beam CT planning in head & neck and pelvic localizations.
Barateau A; Garlopeau C; Cugny A; De Figueiredo BH; Dupin C; Caron J; Antoine M
Phys Med; 2015 Mar; 31(2):146-51. PubMed ID: 25595131
[TBL] [Abstract][Full Text] [Related]
14. Radiotherapy dose calculation on KV cone-beam CT image for lung tumor using the CIRS calibration.
Ma C; Cao J; Yin Y; Zhu J
Thorac Cancer; 2014 Jan; 5(1):68-73. PubMed ID: 26766975
[TBL] [Abstract][Full Text] [Related]
15. Dose calculation accuracy using cone-beam CT (CBCT) for pelvic adaptive radiotherapy.
Guan H; Dong H
Phys Med Biol; 2009 Oct; 54(20):6239-50. PubMed ID: 19794241
[TBL] [Abstract][Full Text] [Related]
16. Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients.
Létourneau D; Martinez AA; Lockman D; Yan D; Vargas C; Ivaldi G; Wong J
Int J Radiat Oncol Biol Phys; 2005 Jul; 62(4):1239-46. PubMed ID: 15913917
[TBL] [Abstract][Full Text] [Related]
17. Feasibility of CBCT-based proton dose calculation using a histogram-matching algorithm in proton beam therapy.
Arai K; Kadoya N; Kato T; Endo H; Komori S; Abe Y; Nakamura T; Wada H; Kikuchi Y; Takai Y; Jingu K
Phys Med; 2017 Jan; 33():68-76. PubMed ID: 27998666
[TBL] [Abstract][Full Text] [Related]
18. Comparison of CBCT-based dose calculation methods in head and neck cancer radiotherapy: from Hounsfield unit to density calibration curve to deep learning.
Barateau A; De Crevoisier R; Largent A; Mylona E; Perichon N; Castelli J; Chajon E; Acosta O; Simon A; Nunes JC; Lafond C
Med Phys; 2020 Oct; 47(10):4683-4693. PubMed ID: 32654160
[TBL] [Abstract][Full Text] [Related]
19. An evaluation of techniques for dose calculation on cone beam computed tomography.
Giacometti V; King RB; Agnew CE; Irvine DM; Jain S; Hounsell AR; McGarry CK
Br J Radiol; 2019 Apr; 92(1096):20180383. PubMed ID: 30433821
[TBL] [Abstract][Full Text] [Related]
20. 2D antiscatter grid and scatter sampling based CBCT method for online dose calculations during CBCT guided radiation therapy of pelvis.
Bayat F; Miller B; Park Y; Yu Z; Alexeev T; Thomas D; Stuhr K; Kavanagh B; Miften M; Altunbas C
Med Phys; 2024 Apr; 51(4):3053-3066. PubMed ID: 38043086
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]