BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 17237587)

  • 1. An inexpensive, MRI compatible device to measure tidal volume from chest-wall circumference.
    Binks AP; Banzett RB; Duvivier C
    Physiol Meas; 2007 Feb; 28(2):149-59. PubMed ID: 17237587
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Occlusion maneuver to detect the relative contribution of the rib cage and abdomen to tidal volume using respiratory inductive plethysmography in infants.
    Gagliardi L; Rusconi F; Aston H; Silverman M
    Pediatr Pulmonol; 1996 Feb; 21(2):132-7. PubMed ID: 8882215
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction.
    Cohen KP; Ladd WM; Beams DM; Sheers WS; Radwin RG; Tompkins WJ; Webster JG
    IEEE Trans Biomed Eng; 1997 Jul; 44(7):555-66. PubMed ID: 9210815
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Chest wall kinematics, respiratory muscle action and dyspnoea during arm vs. leg exercise in humans.
    Romagnoli I; Gorini M; Gigliotti F; Bianchi R; Lanini B; Grazzini M; Stendardi L; Scano G
    Acta Physiol (Oxf); 2006 Sep; 188(1):63-73. PubMed ID: 16911254
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of pulmonary flow using impedance pneumography.
    Seppä VP; Viik J; Hyttinen J
    IEEE Trans Biomed Eng; 2010 Sep; 57(9):2277-85. PubMed ID: 20542759
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of thoracic impedance sensors to screen for sleep-disordered breathing in patients with cardiovascular disease.
    Poupard L; Mathieu M; Sartène R; Goldman M
    Physiol Meas; 2008 Feb; 29(2):255-67. PubMed ID: 18256456
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Four methods of measuring tidal volume during high-frequency oscillatory ventilation.
    Hager DN; Fuld M; Kaczka DW; Fessler HE; Brower RG; Simon BA
    Crit Care Med; 2006 Mar; 34(3):751-7. PubMed ID: 16505661
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Respiratory inductance plethysmography: calibration techniques, their validation and the effects of posture.
    Stradling JR; Chadwick GA; Quirk C; Phillips T
    Bull Eur Physiopathol Respir; 1985; 21(4):317-24. PubMed ID: 4041657
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measuring tidal breathing parameters using a volumetric vest in neonates with and without lung disease.
    Olden C; Symes E; Seddon P
    Pediatr Pulmonol; 2010 Nov; 45(11):1070-5. PubMed ID: 20872815
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Chest wall kinematics and Hoover's sign.
    Binazzi B; Bianchi R; Romagnoli I; Lanini B; Stendardi L; Gigliotti F; Scano G
    Respir Physiol Neurobiol; 2008 Feb; 160(3):325-33. PubMed ID: 18088571
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reliability of respiratory tidal volume estimation by means of ambulatory inductive plethysmography.
    Grossman P; Spoerle M; Wilhelm FH
    Biomed Sci Instrum; 2006; 42():193-8. PubMed ID: 16817607
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Gas inertia and ventilatory measurements under pressure: methodological considerations.
    Hickey DD; Marky DC; Smith RJ
    Undersea Biomed Res; 1983 Dec; 10(4):273-9. PubMed ID: 6675225
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Breathing pattern and kinematics in normal subjects during speech, singing and loud whispering.
    Binazzi B; Lanini B; Bianchi R; Romagnoli I; Nerini M; Gigliotti F; Duranti R; Milic-Emili J; Scano G
    Acta Physiol (Oxf); 2006 Mar; 186(3):233-46. PubMed ID: 16497202
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Changes in the contribution of the rib cage to tidal breathing during infancy.
    Hershenson MB; Colin AA; Wohl ME; Stark AR
    Am Rev Respir Dis; 1990 Apr; 141(4 Pt 1):922-5. PubMed ID: 2139308
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Voluntary control of thoracic and abdominal respiratory movements].
    Miniaev VI; Petushkov MN
    Fiziol Cheloveka; 2005; 31(6):44-8. PubMed ID: 16366150
    [No Abstract]   [Full Text] [Related]  

  • 16. Evaluation of the respiratory inductive plethysmograph in man.
    Guyatt AR; McBride MJ; Meanock CI
    Eur J Respir Dis; 1983 Feb; 64(2):81-9. PubMed ID: 6832253
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Patterns of chest wall kinematics during volitional pursed-lip breathing in COPD at rest.
    Bianchi R; Gigliotti F; Romagnoli I; Lanini B; Castellani C; Binazzi B; Stendardi L; Grazzini M; Scano G
    Respir Med; 2007 Jul; 101(7):1412-8. PubMed ID: 17350815
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Speaking and breathing in high respiratory drive.
    Bailey EF; Hoit JD
    J Speech Lang Hear Res; 2002 Feb; 45(1):89-99. PubMed ID: 14748641
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of volume and leak measurements during CPAP using a neonatal lung model.
    Fischer HS; Roehr CC; Proquitté H; Wauer RR; Schmalisch G
    Physiol Meas; 2008 Jan; 29(1):95-107. PubMed ID: 18175862
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.