107 related articles for article (PubMed ID: 17251229)
1. Automatic detection of sleep-disordered breathing from a single-channel airflow record.
Nakano H; Tanigawa T; Furukawa T; Nishima S
Eur Respir J; 2007 Apr; 29(4):728-36. PubMed ID: 17251229
[TBL] [Abstract][Full Text] [Related]
2. Validation of a single-channel airflow monitor for screening of sleep-disordered breathing.
Nakano H; Tanigawa T; Ohnishi Y; Uemori H; Senzaki K; Furukawa T; Nishima S
Eur Respir J; 2008 Oct; 32(4):1060-7. PubMed ID: 18480104
[TBL] [Abstract][Full Text] [Related]
3. Nonlinear features for single-channel diagnosis of sleep-disordered breathing diseases.
Rathnayake SI; Wood IA; Abeyratne UR; Hukins C
IEEE Trans Biomed Eng; 2010 Aug; 57(8):1973-81. PubMed ID: 20211800
[TBL] [Abstract][Full Text] [Related]
4. Detection of apneic events from single channel nasal airflow using 2nd derivative method.
Han J; Shin HB; Jeong DU; Park KS
Comput Methods Programs Biomed; 2008 Sep; 91(3):199-207. PubMed ID: 18571281
[TBL] [Abstract][Full Text] [Related]
5. [Validation of microMESAM as screening device for sleep disordered breathing].
Wang Y; Teschler T; Weinreich G; Hess S; Wessendorf TE; Teschler H
Pneumologie; 2003 Dec; 57(12):734-40. PubMed ID: 14681746
[TBL] [Abstract][Full Text] [Related]
6. An invasive and a noninvasive approach for the automatic differentiation of obstructive and central hypopneas.
Morgenstern C; Schwaibold M; Randerath WJ; Bolz A; Jané R
IEEE Trans Biomed Eng; 2010 Aug; 57(8):1927-36. PubMed ID: 20403779
[TBL] [Abstract][Full Text] [Related]
7. Comparison of nasal prong pressure and thermistor measurements for detecting respiratory events during sleep.
BaHammam A
Respiration; 2004; 71(4):385-90. PubMed ID: 15316213
[TBL] [Abstract][Full Text] [Related]
8. Obstructive sleep apnoea syndrome: comparison between polysomnography and portable sleep monitoring based on jaw recordings.
Cheliout-Heraut F; Senny F; Djouadi F; Ouayoun M; Bour F
Neurophysiol Clin; 2011 Oct; 41(4):191-8. PubMed ID: 22078731
[TBL] [Abstract][Full Text] [Related]
9. Sleep apnea diagnosis using an ECG Holter device including a nasal pressure (NP) recording: validation of visual and automatic analysis of nasal pressure versus full polysomnography.
Pépin JL; Defaye P; Vincent E; Christophle-Boulard S; Tamisier R; Lévy P
Sleep Med; 2009 Jun; 10(6):651-6. PubMed ID: 19028140
[TBL] [Abstract][Full Text] [Related]
10. Feasibility of automated detection of advanced sleep disordered breathing utilizing an implantable pacemaker ventilation sensor.
Shalaby A; Atwood C; Hansen C; Konermann M; Jamnadas P; Lee K; Willems R; Hartley J; Stahmann J; Kwok J; Ni Q; Neuzner J
Pacing Clin Electrophysiol; 2006 Oct; 29(10):1036-43. PubMed ID: 17038134
[TBL] [Abstract][Full Text] [Related]
11. Assessment of sleep-disordered breathing using a non-contact bio-motion sensor.
Zaffaroni A; Kent B; O'Hare E; Heneghan C; Boyle P; O'Connell G; Pallin M; de Chazal P; McNicholas WT
J Sleep Res; 2013 Apr; 22(2):231-6. PubMed ID: 23176607
[TBL] [Abstract][Full Text] [Related]
12. Screening for sleep-related breathing disorders by transthoracic impedance recording integrated into a Holter ECG system.
Mueller A; Fietze I; Voelker R; Eddicks S; Glos M; Baumann G; Theres H
J Sleep Res; 2006 Dec; 15(4):455-62. PubMed ID: 17118103
[TBL] [Abstract][Full Text] [Related]
13. Scoring respiratory events in paediatric patients: evaluation of nasal pressure and thermistor recordings separately and in combination.
Verginis N; Davey MJ; Horne RS
Sleep Med; 2010 Apr; 11(4):400-5. PubMed ID: 20189872
[TBL] [Abstract][Full Text] [Related]
14. Validation of a self-applied unattended monitor for sleep disordered breathing.
Ayappa I; Norman RG; Seelall V; Rapoport DM
J Clin Sleep Med; 2008 Feb; 4(1):26-37. PubMed ID: 18350959
[TBL] [Abstract][Full Text] [Related]
15. Usefulness of ambulatory ECG in the diagnosis of sleep-related breathing disorders.
Ozegowski S; Wilczyńska E; Piorunek T; Szymanowska K; Paluszkiewicz L
Kardiol Pol; 2007 Nov; 65(11):1321-8; discussion 1329-30. PubMed ID: 18058583
[TBL] [Abstract][Full Text] [Related]
16. Analysis of the interbeat interval increment to detect obstructive sleep apnoea/hypopnoea.
Roche F; Celle S; Pichot V; Barthélémy JC; Sforza E
Eur Respir J; 2007 Jun; 29(6):1206-11. PubMed ID: 17301093
[TBL] [Abstract][Full Text] [Related]
17. Sleep/wake measurement using a non-contact biomotion sensor.
De Chazal P; Fox N; O'Hare E; Heneghan C; Zaffaroni A; Boyle P; Smith S; O'Connell C; McNicholas WT
J Sleep Res; 2011 Jun; 20(2):356-66. PubMed ID: 20704645
[TBL] [Abstract][Full Text] [Related]
18. [Evaluation of a new automatic CPAP algorithm in the treatment of obstructive sleep apnoea syndrome].
Galetke W; Stieglitz S; Anduleit N; Kenter M; Kühnel J; Osagie-Paech R; Richter K; Randerath W
Pneumologie; 2009 May; 63(5):261-5. PubMed ID: 19229797
[TBL] [Abstract][Full Text] [Related]
19. Mandibular position and movements: Suitability for diagnosis of sleep apnoea.
Martinot JB; Borel JC; Cuthbert V; Guénard HJ; Denison S; Silkoff PE; Gozal D; Pepin JL
Respirology; 2017 Apr; 22(3):567-574. PubMed ID: 28225162
[TBL] [Abstract][Full Text] [Related]
20. The minimum period of polysomnography required to confirm a diagnosis of severe obstructive sleep apnoea.
Chou KT; Chang YT; Chen YM; Su KC; Perng DW; Chang SC; Shiao GM
Respirology; 2011 Oct; 16(7):1096-102. PubMed ID: 21762445
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]