These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 17255183)

  • 1. Noninvasive temperature estimation using sonographic digital images.
    Abolhassani MD; Norouzy A; Takavar A; Ghanaati H
    J Ultrasound Med; 2007 Feb; 26(2):215-22. PubMed ID: 17255183
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An efficient temperature estimation using optical-flow in ultrasound B-mode digital images.
    Mehrabani BM; Tavakoli V; Abolhassani MD; Alirezaie J; Ahmadian A
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():86-9. PubMed ID: 19162600
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers.
    Bazán I; Vazquez M; Ramos A; Vera A; Leija L
    Ultrasonics; 2009 Mar; 49(3):358-76. PubMed ID: 19100591
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On the possibility of non-invasive multilayer temperature estimation using soft-computing methods.
    Teixeira CA; Pereira WC; Ruano AE; Ruano MG
    Ultrasonics; 2010 Jan; 50(1):32-43. PubMed ID: 19695653
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determining temperature distribution in tissue in the focal plane of the high (>100 W/cm(2)) intensity focused ultrasound beam using phase shift of ultrasound echoes.
    Karwat P; Kujawska T; Lewin PA; Secomski W; Gambin B; Litniewski J
    Ultrasonics; 2016 Feb; 65():211-9. PubMed ID: 26498063
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimized noninvasive monitoring of thermal changes on digital B-mode renal sonography during revascularization therapy.
    Abolhassani MD; Tavakoli V; Sahba N
    J Ultrasound Med; 2009 Nov; 28(11):1535-47. PubMed ID: 19854969
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Temperature dependence of ultrasonic backscattered energy in motion-compensated images.
    Arthur RM; Trobaugh JW; Straube WL; Moros EG
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Oct; 52(10):1644-52. PubMed ID: 16382617
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Temperature estimation using ultrasonic spatial compound imaging.
    Pernot M; Tanter M; Bercoff J; Waters KR; Fink M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2004 May; 51(5):606-15. PubMed ID: 15217237
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three-dimensional spatial and temporal temperature imaging in gel phantoms using backscattered ultrasound.
    Anand A; Savéry D; Hall C
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Jan; 54(1):23-31. PubMed ID: 17225797
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasound thermal mapping based on a hybrid method combining physical and statistical models.
    Chen BT; Shieh J; Huang CW; Chen WS; Chen SR; Chen CS
    Ultrasound Med Biol; 2014 Jan; 40(1):115-29. PubMed ID: 24210856
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Non-invasive ultrasound-based temperature imaging for monitoring radiofrequency heating-phantom results.
    Daniels MJ; Varghese T; Madsen EL; Zagzebski JA
    Phys Med Biol; 2007 Aug; 52(16):4827-43. PubMed ID: 17671338
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Motion estimation in ultrasound images using time domain cross correlation with prior estimates.
    Zahiri-Azar R; Salcudean SE
    IEEE Trans Biomed Eng; 2006 Oct; 53(10):1990-2000. PubMed ID: 17019863
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo ultrasound thermography in presence of temperature heterogeneity and natural motions.
    Bayat M; Ballard JR; Ebbini ES
    IEEE Trans Biomed Eng; 2015 Feb; 62(2):450-457. PubMed ID: 25248172
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasound phase-contrast transmission imaging of localized thermal variation and the identification of fat/tissue boundaries.
    Clement GT; Hynynen K
    Phys Med Biol; 2005 Apr; 50(7):1585-600. PubMed ID: 15798345
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vivo noninvasive temperature measurement by B-mode ultrasound imaging.
    Pouch AM; Cary TW; Schultz SM; Sehgal CM
    J Ultrasound Med; 2010 Nov; 29(11):1595-606. PubMed ID: 20966471
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analysis of motion tracking in echocardiographic image sequences: influence of system geometry and point-spread function.
    Touil B; Basarab A; Delachartre P; Bernard O; Friboulet D
    Ultrasonics; 2010 Mar; 50(3):373-86. PubMed ID: 19837445
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrasound thermal change detection based on steerable filters.
    Sahba N; Tavakoli V; Nambakhsh M
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():2984-7. PubMed ID: 19163333
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A multi-gate time-of-flight technique for estimation of temperature distribution in heated tissue: theory and computer simulation.
    Sun Z; Ying H
    Ultrasonics; 1999 Feb; 37(2):107-22. PubMed ID: 10209554
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thermoacoustic and photoacoustic sensing of temperature.
    Pramanik M; Wang LV
    J Biomed Opt; 2009; 14(5):054024. PubMed ID: 19895126
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Estimation of average speed of sound using deconvolution of medical ultrasound data.
    Shin HC; Prager R; Gomersall H; Kingsbury N; Treece G; Gee A
    Ultrasound Med Biol; 2010 Apr; 36(4):623-36. PubMed ID: 20350687
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.