205 related articles for article (PubMed ID: 17259143)
1. [Genetic algorithm-based dose optimization in intensity modulated radiation therapy].
Zhou LH; Tang MT; Wang ZY; Chen CM; Lü QW; Jin HY
Nan Fang Yi Ke Da Xue Xue Bao; 2007 Jan; 27(1):46-8. PubMed ID: 17259143
[TBL] [Abstract][Full Text] [Related]
2. [A preliminary study of beam weight optimization of intensity-modulated radiation therapy with genetic algorithm].
Tang MT; Chen CM; Zhou LH; Lü QW; Wang ZY; Chen GJ
Nan Fang Yi Ke Da Xue Xue Bao; 2006 Apr; 26(4):456-8. PubMed ID: 16624751
[TBL] [Abstract][Full Text] [Related]
3. Development of methods for beam angle optimization for IMRT using an accelerated exhaustive search strategy.
Wang X; Zhang X; Dong L; Liu H; Wu Q; Mohan R
Int J Radiat Oncol Biol Phys; 2004 Nov; 60(4):1325-37. PubMed ID: 15519806
[TBL] [Abstract][Full Text] [Related]
4. A particle swarm optimization algorithm for beam angle selection in intensity-modulated radiotherapy planning.
Li Y; Yao D; Yao J; Chen W
Phys Med Biol; 2005 Aug; 50(15):3491-514. PubMed ID: 16030379
[TBL] [Abstract][Full Text] [Related]
5. The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework.
Kratt K; Scherrer A
Phys Med Biol; 2009 Jun; 54(12):N239-46. PubMed ID: 19478380
[TBL] [Abstract][Full Text] [Related]
6. Development of an optimization concept for arc-modulated cone beam therapy.
Ulrich S; Nill S; Oelfke U
Phys Med Biol; 2007 Jul; 52(14):4099-119. PubMed ID: 17664597
[TBL] [Abstract][Full Text] [Related]
7. A novel approach to multi-criteria inverse planning for IMRT.
Breedveld S; Storchi PR; Keijzer M; Heemink AW; Heijmen BJ
Phys Med Biol; 2007 Oct; 52(20):6339-53. PubMed ID: 17921588
[TBL] [Abstract][Full Text] [Related]
8. Using total-variation regularization for intensity modulated radiation therapy inverse planning with field-specific numbers of segments.
Zhu L; Lee L; Ma Y; Ye Y; Mazzeo R; Xing L
Phys Med Biol; 2008 Dec; 53(23):6653-72. PubMed ID: 18997262
[TBL] [Abstract][Full Text] [Related]
9. Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming.
Yang R; Dai J; Yang Y; Hu Y
Phys Med Biol; 2006 Aug; 51(15):3653-66. PubMed ID: 16861772
[TBL] [Abstract][Full Text] [Related]
10. A unified approach for inversion problems in intensity-modulated radiation therapy.
Censor Y; Bortfeld T; Martin B; Trofimov A
Phys Med Biol; 2006 May; 51(10):2353-65. PubMed ID: 16675857
[TBL] [Abstract][Full Text] [Related]
11. Patient-specific IMRT verification using independent fluence-based dose calculation software: experimental benchmarking and initial clinical experience.
Georg D; Stock M; Kroupa B; Olofsson J; Nyholm T; Ahnesjö A; Karlsson M
Phys Med Biol; 2007 Aug; 52(16):4981-92. PubMed ID: 17671348
[TBL] [Abstract][Full Text] [Related]
12. Clinical evaluation of direct aperture optimization when applied to head-and-neck IMRT.
Jones S; Williams M
Med Dosim; 2008; 33(1):86-92. PubMed ID: 18262129
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric and radiobiologic comparison of 3D conformal versus intensity modulated planning techniques for prostate bed radiotherapy.
Koontz BF; Das S; Temple K; Bynum S; Catalano S; Koontz JI; Montana GS; Oleson JR
Med Dosim; 2009; 34(3):256-60. PubMed ID: 19647638
[TBL] [Abstract][Full Text] [Related]
14. A comparison of conformal and intensity modulated treatment planning techniques for early prostate cancer.
Vaarkamp J; Malde R; Dixit S; Hamilton CS
J Med Imaging Radiat Oncol; 2009 Jun; 53(3):310-7. PubMed ID: 19624299
[TBL] [Abstract][Full Text] [Related]
15. Assessment and minimization of contralateral breast dose for conventional and intensity modulated breast radiotherapy.
Burmeister J; Alvarado N; Way S; McDermott P; Bossenberger T; Jaenisch H; Patel R; Washington T
Med Dosim; 2008; 33(1):6-13. PubMed ID: 18262117
[TBL] [Abstract][Full Text] [Related]
16. A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer.
Kim Y; Verhey LJ; Xia P
Phys Med Biol; 2007 Apr; 52(8):2147-56. PubMed ID: 17404460
[TBL] [Abstract][Full Text] [Related]
17. A Monte Carlo-based procedure for independent monitor unit calculation in IMRT treatment plans.
Pisaturo O; Moeckli R; Mirimanoff RO; Bochud FO
Phys Med Biol; 2009 Jul; 54(13):4299-310. PubMed ID: 19531844
[TBL] [Abstract][Full Text] [Related]
18. [The automatic optimization arithmetic of selecting beam arcs in X-knife radiotherapy planning system].
Liu YX; Li SX; Lu QW
Zhongguo Yi Liao Qi Xie Za Zhi; 2002 Jan; 26(1):20-2. PubMed ID: 16104151
[TBL] [Abstract][Full Text] [Related]
19. Sweeping-window arc therapy: an implementation of rotational IMRT with automatic beam-weight calculation.
Cameron C
Phys Med Biol; 2005 Sep; 50(18):4317-36. PubMed ID: 16148396
[TBL] [Abstract][Full Text] [Related]
20. Fast multifield optimization of the biological effect in ion therapy.
Wilkens JJ; Oelfke U
Phys Med Biol; 2006 Jun; 51(12):3127-40. PubMed ID: 16757867
[TBL] [Abstract][Full Text] [Related]