584 related articles for article (PubMed ID: 17260077)
1. Bi-functionalization of a patterned Prussian blue array for amperometric measurement of glucose via two integrated detection schemes.
Zhang N; Wilkop T; Lee S; Cheng Q
Analyst; 2007 Feb; 132(2):164-72. PubMed ID: 17260077
[TBL] [Abstract][Full Text] [Related]
2. Amperometric glucose biosensors based on layer-by-layer assembly of chitosan and glucose oxidase on the Prussian blue-modified gold electrode.
Yin B; Yuan R; Chai Y; Chen S; Cao S; Xu Y; Fu P
Biotechnol Lett; 2008 Feb; 30(2):317-22. PubMed ID: 17912595
[TBL] [Abstract][Full Text] [Related]
3. Multilayer membranes via layer-by-layer deposition of organic polymer protected Prussian blue nanoparticles and glucose oxidase for glucose biosensing.
Zhao W; Xu JJ; Shi CG; Chen HY
Langmuir; 2005 Oct; 21(21):9630-4. PubMed ID: 16207046
[TBL] [Abstract][Full Text] [Related]
4. DNA as a support for glucose oxidase immobilization at Prussian blue-modified glassy carbon electrode in biosensor preparation.
Kafi AK; Lee DY; Park SH; Kwon YS
J Nanosci Nanotechnol; 2006 Nov; 6(11):3539-42. PubMed ID: 17252806
[TBL] [Abstract][Full Text] [Related]
5. A glucose biosensor based on Prussian blue/chitosan hybrid film.
Wang X; Gu H; Yin F; Tu Y
Biosens Bioelectron; 2009 Jan; 24(5):1527-30. PubMed ID: 19010659
[TBL] [Abstract][Full Text] [Related]
6. Pt based enzyme electrode probes assembled with Prussian Blue and conducting polymer nanostructures.
Curulli A; Valentini F; Orlanduci S; Terranova ML; Palleschi G
Biosens Bioelectron; 2004 Dec; 20(6):1223-32. PubMed ID: 15556371
[TBL] [Abstract][Full Text] [Related]
7. Preparation and characterization of Prussian blue nanowire array and bioapplication for glucose biosensing.
Qu F; Shi A; Yang M; Jiang J; Shen G; Yu R
Anal Chim Acta; 2007 Dec; 605(1):28-33. PubMed ID: 18022407
[TBL] [Abstract][Full Text] [Related]
8. Fabrication of self-assembled oligophenylethynylenethiol monolayer for electrochemical glucose biosensor.
Jung SK; Namgung MO; Oh SY; Oh BK
Ultramicroscopy; 2009 Jul; 109(8):911-5. PubMed ID: 19369004
[TBL] [Abstract][Full Text] [Related]
9. Multilayer assembly of Prussian blue nanoclusters and enzyme-immobilized poly(toluidine blue) films and its application in glucose biosensor construction.
Zhang D; Zhang K; Yao YL; Xia XH; Chen HY
Langmuir; 2004 Aug; 20(17):7303-7. PubMed ID: 15301519
[TBL] [Abstract][Full Text] [Related]
10. Incorporation of glucose oxidase into Langmuir-Blodgett films based on Prussian blue applied to amperometric glucose biosensor.
Ohnuki H; Saiki T; Kusakari A; Endo H; Ichihara M; Izumi M
Langmuir; 2007 Apr; 23(8):4675-81. PubMed ID: 17367170
[TBL] [Abstract][Full Text] [Related]
11. Novel planar glucose biosensors for continuous monitoring use.
Ricci F; Moscone D; Tuta CS; Palleschi G; Amine A; Poscia A; Valgimigli F; Messeri D
Biosens Bioelectron; 2005 Apr; 20(10):1993-2000. PubMed ID: 15741068
[TBL] [Abstract][Full Text] [Related]
12. A novel method for glucose determination based on electrochemical impedance spectroscopy using glucose oxidase self-assembled biosensor.
Shervedani RK; Mehrjardi AH; Zamiri N
Bioelectrochemistry; 2006 Oct; 69(2):201-8. PubMed ID: 16580891
[TBL] [Abstract][Full Text] [Related]
13. Electropolymerization of preoxidized catecholamines on Prussian blue matrix to immobilize glucose oxidase for sensitive amperometric biosensing.
Chen C; Fu Y; Xiang C; Xie Q; Zhang Q; Su Y; Wang L; Yao S
Biosens Bioelectron; 2009 Apr; 24(8):2726-9. PubMed ID: 19167205
[TBL] [Abstract][Full Text] [Related]
14. Template synthesis of highly ordered Prussian blue array and its application to the glucose biosensing.
Xian Y; Hu Y; Liu F; Xian Y; Feng L; Jin L
Biosens Bioelectron; 2007 Jun; 22(12):2827-33. PubMed ID: 17188857
[TBL] [Abstract][Full Text] [Related]
15. Bienzyme HRP-GOx-modified gold nanoelectrodes for the sensitive amperometric detection of glucose at low overpotentials.
Delvaux M; Walcarius A; Demoustier-Champagne S
Biosens Bioelectron; 2005 Feb; 20(8):1587-94. PubMed ID: 15626613
[TBL] [Abstract][Full Text] [Related]
16. Improvement of homogeneity of analytical biodevices by gene manipulation.
Shi JX; Zhang XE; Xie WH; Zhou YF; Zhang ZP; Deng JY; Cass AE; Zhang ZL; Pang DW; Zhang CG
Anal Chem; 2004 Feb; 76(3):632-8. PubMed ID: 14750857
[TBL] [Abstract][Full Text] [Related]
17. Redox polymer and probe DNA tethered to gold electrodes for enzyme-amplified amperometric detection of DNA hybridization.
Kavanagh P; Leech D
Anal Chem; 2006 Apr; 78(8):2710-6. PubMed ID: 16615783
[TBL] [Abstract][Full Text] [Related]
18. Improved sensitivity and stability of amperometric enzyme microbiosensors by covalent attachment to gold electrodes.
Masson JF; Kranz C; Booksh KS; Mizaikoff B
Biosens Bioelectron; 2007 Oct; 23(3):355-61. PubMed ID: 17560101
[TBL] [Abstract][Full Text] [Related]
19. Amperometric glucose biosensor based on layer-by-layer covalent attachment of AMWNTs and IO(4)(-)-oxidized GOx.
Sun Y; Wang H; Sun C
Biosens Bioelectron; 2008 Sep; 24(1):22-8. PubMed ID: 18440797
[TBL] [Abstract][Full Text] [Related]
20. Multilayered construction of glucose oxidase and silica nanoparticles on Au electrodes based on layer-by-layer covalent attachment.
Sun Y; Yan F; Yang W; Sun C
Biomaterials; 2006 Jul; 27(21):4042-9. PubMed ID: 16566998
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]