125 related articles for article (PubMed ID: 17260355)
21. Macroscopic susceptibility in ultra high field MRI.
Abduljalil AM; Robitaille PM
J Comput Assist Tomogr; 1999; 23(6):832-41. PubMed ID: 10589555
[TBL] [Abstract][Full Text] [Related]
22. Macroscopic susceptibility in ultra high field MRI. II: acquisition of spin echo images from the human head.
Abduljalil AM; Kangarlu A; Yu Y; Robitaille PM
J Comput Assist Tomogr; 1999; 23(6):842-4. PubMed ID: 10589556
[TBL] [Abstract][Full Text] [Related]
23. Asymmetric spin-echo (ASE) spiral improves BOLD fMRI in inhomogeneous regions.
Brewer KD; Rioux JA; D'Arcy RC; Bowen CV; Beyea SD
NMR Biomed; 2009 Jul; 22(6):654-62. PubMed ID: 19382109
[TBL] [Abstract][Full Text] [Related]
24. An efficient automated z-shim based method to correct through-slice signal loss in EPI at 3T.
Marshall H; Hajnal JV; Warren JE; Wise RJ; Larkman DJ
MAGMA; 2009 Jun; 22(3):187-200. PubMed ID: 19238472
[TBL] [Abstract][Full Text] [Related]
25. Automated slice-specific z-shimming for functional magnetic resonance imaging of the human spinal cord.
Kaptan M; Vannesjo SJ; Mildner T; Horn U; Hartley-Davies R; Oliva V; Brooks JCW; Weiskopf N; Finsterbusch J; Eippert F
Hum Brain Mapp; 2022 Dec; 43(18):5389-5407. PubMed ID: 35938527
[TBL] [Abstract][Full Text] [Related]
26. Multi-gradient echo with susceptibility inhomogeneity compensation (MGESIC): demonstration of fMRI in the olfactory cortex at 3.0 T.
Yang QX; Dardzinski BJ; Li S; Eslinger PJ; Smith MB
Magn Reson Med; 1997 Mar; 37(3):331-5. PubMed ID: 9055220
[TBL] [Abstract][Full Text] [Related]
27. Dynamic shim updating on the human brain.
Koch KM; McIntyre S; Nixon TW; Rothman DL; de Graaf RA
J Magn Reson; 2006 Jun; 180(2):286-96. PubMed ID: 16574443
[TBL] [Abstract][Full Text] [Related]
28. Integration of EEG source imaging and fMRI during continuous viewing of natural movies.
Whittingstall K; Bartels A; Singh V; Kwon S; Logothetis NK
Magn Reson Imaging; 2010 Oct; 28(8):1135-42. PubMed ID: 20579829
[TBL] [Abstract][Full Text] [Related]
29. Mitigation of susceptibility-induced signal loss in neuroimaging using localized shim coils.
Hsu JJ; Glover GH
Magn Reson Med; 2005 Feb; 53(2):243-8. PubMed ID: 15678531
[TBL] [Abstract][Full Text] [Related]
30. Positive or negative blips? The effect of phase encoding scheme on susceptibility-induced signal losses in EPI.
De Panfilis C; Schwarzbauer C
Neuroimage; 2005 Mar; 25(1):112-21. PubMed ID: 15734348
[TBL] [Abstract][Full Text] [Related]
31. Reducing image artefacts in concurrent TMS/fMRI by passive shimming.
Bungert A; Chambers CD; Phillips M; Evans CJ
Neuroimage; 2012 Feb; 59(3):2167-74. PubMed ID: 22019878
[TBL] [Abstract][Full Text] [Related]
32. Dynamic shim updating (DSU) for multislice signal acquisition.
de Graaf RA; Brown PB; McIntyre S; Rothman DL; Nixon TW
Magn Reson Med; 2003 Mar; 49(3):409-16. PubMed ID: 12594742
[TBL] [Abstract][Full Text] [Related]
33. Comparison of fMRI activation as measured with gradient- and spin-echo EPI during visual perception.
Schmidt CF; Boesiger P; Ishai A
Neuroimage; 2005 Jul; 26(3):852-9. PubMed ID: 15955495
[TBL] [Abstract][Full Text] [Related]
34. Real-time autoshimming for echo planar timecourse imaging.
Ward HA; Riederer SJ; Jack CR
Magn Reson Med; 2002 Nov; 48(5):771-80. PubMed ID: 12417991
[TBL] [Abstract][Full Text] [Related]
35. Parallel imaging with asymmetric acceleration to reduce Gibbs artifacts and to increase signal-to-noise ratio of the gradient echo echo-planar imaging sequence for functional MRI.
Jung KJ; Zhao T
Magn Reson Med; 2012 Feb; 67(2):419-27. PubMed ID: 21713976
[TBL] [Abstract][Full Text] [Related]
36. Microimaging at 14 tesla using GESEPI for removal of magnetic susceptibility artifacts in T(2)(*)-weighted image contrast.
Yang QX; Smith MB; Briggs RW; Rycyna RE
J Magn Reson; 1999 Nov; 141(1):1-6. PubMed ID: 10527737
[TBL] [Abstract][Full Text] [Related]
37. Detectability and reproducibility of the olfactory fMRI signal under the influence of magnetic susceptibility artifacts in the primary olfactory cortex.
Lu J; Wang X; Qing Z; Li Z; Zhang W; Liu Y; Yuan L; Cheng L; Li M; Zhu B; Zhang X; Yang QX; Zhang B
Neuroimage; 2018 Sep; 178():613-621. PubMed ID: 29885483
[TBL] [Abstract][Full Text] [Related]
38. On the artifact of a subvoxel susceptibility deviation in spoiled gradient-echo imaging.
Bos C; Viergever MA; Bakker CJ
Magn Reson Med; 2003 Aug; 50(2):400-4. PubMed ID: 12876717
[TBL] [Abstract][Full Text] [Related]
39. Volumetric R2 * mapping using z-shim multi-echo gradient echo imaging.
Han D; Nam Y; Gho SM; Kim DH
Magn Reson Med; 2015 Mar; 73(3):1164-70. PubMed ID: 24664576
[TBL] [Abstract][Full Text] [Related]
40. High-resolution fMRI with higher-order generalized series imaging and parallel imaging techniques (HGS-parallel).
Yun S; Oh SS; Han Y; Park H
J Magn Reson Imaging; 2009 Apr; 29(4):924-36. PubMed ID: 19306432
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]