118 related articles for article (PubMed ID: 17260583)
1. Miniature LiF:Mg,Cu,P TLDs to study the effect of applicator material in 192-Ir brachytherapy.
Hood C; Duggan L; Bazley S; Denham J; Kron T
Australas Phys Eng Sci Med; 2006 Dec; 29(4):300-2. PubMed ID: 17260583
[TBL] [Abstract][Full Text] [Related]
2. LiF:Mg,Cu,P 'pin worms': miniature detectors for brachytherapy dosimetry.
Hood C; Duggan L; Bazley S; Denham J; Budzanowski M; Kron T
Radiat Prot Dosimetry; 2002; 101(1-4):407-10. PubMed ID: 12382778
[TBL] [Abstract][Full Text] [Related]
3. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source.
Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D
Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503
[TBL] [Abstract][Full Text] [Related]
4. Angular and radial dependence of the energy response factor for LIF-TLD micro-rods in 125L permanent implant source.
Mobit P; Badragan I
Radiat Prot Dosimetry; 2006; 120(1-4):70-3. PubMed ID: 16782977
[TBL] [Abstract][Full Text] [Related]
5. Comparison of the effects of exposure to light in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P.
Baker ST; Gilvin PJ
Radiat Prot Dosimetry; 2007; 125(1-4):258-60. PubMed ID: 16980318
[TBL] [Abstract][Full Text] [Related]
6. Energy response of LiF and Mg2SiO4 TLDs to 10-150 keV monoenergetic photons.
Konnai A; Nariyama N; Ohnishi S; Odano N
Radiat Prot Dosimetry; 2005; 115(1-4):334-6. PubMed ID: 16381741
[TBL] [Abstract][Full Text] [Related]
7. Doses to LiF :Ti, Mg chips encapsulated in plastic extremity rings as a result of radon gas exposure.
Kearfott KJ; Noon EP; Rafique M
J Radiol Prot; 2015 Jun; 35(2):265-70. PubMed ID: 25785500
[TBL] [Abstract][Full Text] [Related]
8. Variations in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: implications for clinical dosimetry.
Duggan L; Hood C; Warren-Forward H; Haque M; Kron T
Phys Med Biol; 2004 Sep; 49(17):3831-45. PubMed ID: 15470908
[TBL] [Abstract][Full Text] [Related]
9. Influence of the variation of energy spectra with depth in the dosimetry of 192Ir using LiF TLD.
Meigooni AS; Meli JA; Nath R
Phys Med Biol; 1988 Oct; 33(10):1159-70. PubMed ID: 3194446
[TBL] [Abstract][Full Text] [Related]
10. Dosimetry of densely ionising radiation with three LiF phosphors for space applications.
Bilski P
Radiat Prot Dosimetry; 2006; 120(1-4):397-400. PubMed ID: 16731689
[TBL] [Abstract][Full Text] [Related]
11. Correction factors kE and kQ for LiF-TLDs for dosimetry in megavoltage electron and photon beams.
Bruggmoser G; Saum R; Saum F; Gainey M; Pychlau C; Kapsch RP; Zink K
Z Med Phys; 2015 Jun; 25(2):186-91. PubMed ID: 24973310
[TBL] [Abstract][Full Text] [Related]
12. Comments on 'The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF: Mg.Ti (TLD-100)' by Y.S. Horowitz, L. Oster and H. Datz.
German U; Weinstein M; Abraham A; Alfassi ZB
Radiat Prot Dosimetry; 2008; 128(4):509-10; author reply 510-5. PubMed ID: 18420571
[No Abstract] [Full Text] [Related]
13. Low temperature radioluminescence of LiF:Mg,Cu,P.
Kurt K; Mathur VK; McKeever SW; Townsend PD; Valberg L
Radiat Prot Dosimetry; 2006; 119(1-4):134-8. PubMed ID: 16735562
[TBL] [Abstract][Full Text] [Related]
14. A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry.
Al-Haj A; Lagarde C; Mahyoub F
Radiat Prot Dosimetry; 2007; 125(1-4):399-402. PubMed ID: 17223633
[TBL] [Abstract][Full Text] [Related]
15. Further studies on the role of dopants in LiF:Mg,Cu,Si thermoluminescent material.
Tang K; Fan H; Cui H; Zhu H; Liu Z
Radiat Prot Dosimetry; 2015 Feb; 163(3):288-91. PubMed ID: 24966341
[TBL] [Abstract][Full Text] [Related]
16. Attenuation of intracavitary applicators in 192Ir-HDR brachytherapy.
Ye SJ; Brezovich IA; Shen S; Duan J; Popple RA; Pareek PN
Med Phys; 2004 Jul; 31(7):2097-106. PubMed ID: 15305463
[TBL] [Abstract][Full Text] [Related]
17. The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.
Moscovitch M; St John TJ; Cassata JR; Blake PK; Rotunda JE; Ramlo M; Velbeck KJ; Luo LZ
Radiat Prot Dosimetry; 2006; 119(1-4):248-54. PubMed ID: 16835277
[TBL] [Abstract][Full Text] [Related]
18. Determination of absorbed dose to water around a clinical HDR (192)Ir source using LiF:Mg,Ti TLDs demonstrates an LET dependence of detector response.
Carlsson Tedgren A; Elia R; Hedtjarn H; Olsson S; Alm Carlsson G
Med Phys; 2012 Feb; 39(2):1133-40. PubMed ID: 22320824
[TBL] [Abstract][Full Text] [Related]
19. On the roles of the dopants in LiF: Mg,Cu,Na,Si thermoluminescent material.
Lee JI; Kim JL; Chang SY; Chung KS; Choe HS
Radiat Prot Dosimetry; 2005; 115(1-4):340-4. PubMed ID: 16381743
[TBL] [Abstract][Full Text] [Related]
20. [In vivo dosimetry in interstitial "low dose rate" afterloading therapy with Ir-192 seeds exemplified with head-neck tumors].
Sadat Khonsari A; Grabenbauer G; Müller RG; Säbel M
Strahlenther Onkol; 1991 Jul; 167(7):407-11. PubMed ID: 1858017
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]