276 related articles for article (PubMed ID: 17268013)
1. Artifacts from misaligned CT in cardiac perfusion PET/CT studies: frequency, effects, and potential solutions.
Martinez-Möller A; Souvatzoglou M; Navab N; Schwaiger M; Nekolla SG
J Nucl Med; 2007 Feb; 48(2):188-93. PubMed ID: 17268013
[TBL] [Abstract][Full Text] [Related]
2. Attenuation correction in myocardial perfusion SPECT/CT: effects of misregistration and value of reregistration.
Goetze S; Brown TL; Lavely WC; Zhang Z; Bengel FM
J Nucl Med; 2007 Jul; 48(7):1090-5. PubMed ID: 17574985
[TBL] [Abstract][Full Text] [Related]
3. Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: clinical significance, causes, and solutions.
Loghin C; Sdringola S; Gould KL
J Nucl Med; 2004 Jun; 45(6):1029-39. PubMed ID: 15181138
[TBL] [Abstract][Full Text] [Related]
4. Reducing radiation dose in rest-stress cardiac PET/CT by single poststress cine CT for attenuation correction: quantitative validation.
Gould KL; Pan T; Loghin C; Johnson NP; Sdringola S
J Nucl Med; 2008 May; 49(5):738-45. PubMed ID: 18413384
[TBL] [Abstract][Full Text] [Related]
5. Automatic registration of misaligned CT attenuation correction maps in Rb-82 PET/CT improves detection of angiographically significant coronary artery disease.
Slomka PJ; Diaz-Zamudio M; Dey D; Motwani M; Brodov Y; Choi D; Hayes S; Thomson L; Friedman J; Germano G; Berman D
J Nucl Cardiol; 2015 Dec; 22(6):1285-95. PubMed ID: 25698471
[TBL] [Abstract][Full Text] [Related]
6. The impact of transmission-emission misregistration on the interpretation of SPET/CT myocardial perfusion studies and the value of misregistration correction.
Apostolopoulos DJ; Gąsowska M; Savvopoulos CA; Skouras T; Spyridonidis T; Andrejczuk A; Vassilakos PJ
Hell J Nucl Med; 2015; 18(2):114-21. PubMed ID: 26187210
[TBL] [Abstract][Full Text] [Related]
7. Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: a definitive analysis of causes, consequences, and corrections.
Gould KL; Pan T; Loghin C; Johnson NP; Guha A; Sdringola S
J Nucl Med; 2007 Jul; 48(7):1112-21. PubMed ID: 17574974
[TBL] [Abstract][Full Text] [Related]
8. Attenuation correction of myocardial SPECT perfusion images with low-dose CT: evaluation of the method by comparison with perfusion PET.
Fricke E; Fricke H; Weise R; Kammeier A; Hagedorn R; Lotz N; Lindner O; Tschoepe D; Burchert W
J Nucl Med; 2005 May; 46(5):736-44. PubMed ID: 15872344
[TBL] [Abstract][Full Text] [Related]
9. Minimizing artifacts resulting from respiratory and cardiac motion by optimization of the transmission scan in cardiac PET/CT.
Nye JA; Esteves F; Votaw JR
Med Phys; 2007 Jun; 34(6):1901-6. PubMed ID: 17654891
[TBL] [Abstract][Full Text] [Related]
10. Comparison of myocardial perfusion 82Rb PET performed with CT- and transmission CT-based attenuation correction.
Slomka PJ; Le Meunier L; Hayes SW; Acampa W; Oba M; Haemer GG; Berman DS; Germano G
J Nucl Med; 2008 Dec; 49(12):1992-8. PubMed ID: 19038996
[TBL] [Abstract][Full Text] [Related]
11. Coronary calcium score scan-based attenuation correction in cardiovascular PET imaging.
Ghafarian P; Aghamiri SM; Ay MR; Fallahi B; Rahmim A; Schindler TH; Ratib O; Zaidi H
Nucl Med Commun; 2010 Sep; 31(9):780-7. PubMed ID: 20559155
[TBL] [Abstract][Full Text] [Related]
12. The Effect of Misregistration Between CT-Attenuation and PET-Emission Images in 13N-Ammonia Myocardial PET/CT.
Tomita Y; Ishida M; Ichikawa Y; Suzawa N; Kobayashi S; Maeda H; Takeda K; Sakuma H
J Nucl Med Technol; 2016 Jun; 44(2):73-7. PubMed ID: 27102660
[TBL] [Abstract][Full Text] [Related]
13. Directions and magnitudes of misregistration of CT attenuation-corrected myocardial perfusion studies: incidence, impact on image quality, and guidance for reregistration.
Kennedy JA; Israel O; Frenkel A
J Nucl Med; 2009 Sep; 50(9):1471-8. PubMed ID: 19690038
[TBL] [Abstract][Full Text] [Related]
14. Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT.
Goetze S; Wahl RL
J Nucl Cardiol; 2007 Apr; 14(2):200-6. PubMed ID: 17386382
[TBL] [Abstract][Full Text] [Related]
15. Attenuation-emission alignment in cardiac PET/CT based on consistency conditions.
Alessio AM; Kinahan PE; Champley KM; Caldwell JH
Med Phys; 2010 Mar; 37(3):1191-200. PubMed ID: 20384256
[TBL] [Abstract][Full Text] [Related]
16. Comparison of low-pitch and respiratory-averaged CT protocols for attenuation correction of cardiac PET studies.
Nye JA; Hamill J; Tudorascu D; Carew J; Esteves F; Votaw JR
Med Phys; 2009 May; 36(5):1618-23. PubMed ID: 19544778
[TBL] [Abstract][Full Text] [Related]
17. A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT Introduced by misalignment between emission scan and CT-derived attenuation maps.
Fricke H; Fricke E; Weise R; Kammeier A; Lindner O; Burchert W
J Nucl Med; 2004 Oct; 45(10):1619-25. PubMed ID: 15471824
[TBL] [Abstract][Full Text] [Related]
18. Single-phase CT aligned to gated PET for respiratory motion correction in cardiac PET/CT.
Wells RG; Ruddy TD; DeKemp RA; DaSilva JN; Beanlands RS
J Nucl Med; 2010 Aug; 51(8):1182-90. PubMed ID: 20660386
[TBL] [Abstract][Full Text] [Related]
19. Correction for oral contrast artifacts in CT attenuation-corrected PET images obtained by combined PET/CT.
Nehmeh SA; Erdi YE; Kalaigian H; Kolbert KS; Pan T; Yeung H; Squire O; Sinha A; Larson SM; Humm JL
J Nucl Med; 2003 Dec; 44(12):1940-4. PubMed ID: 14660720
[TBL] [Abstract][Full Text] [Related]
20. Automated cardiac motion compensation in PET/CT for accurate reconstruction of PET myocardial perfusion images.
Khurshid K; McGough RJ; Berger K
Phys Med Biol; 2008 Oct; 53(20):5705-18. PubMed ID: 18812649
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]