BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

349 related articles for article (PubMed ID: 17269143)

  • 21. In vivo behavior and mechanical stability of surface-modified titanium implants by plasma spray coating and chemical treatments.
    Lee BH; Kim JK; Kim YD; Choi K; Lee KH
    J Biomed Mater Res A; 2004 May; 69(2):279-85. PubMed ID: 15058000
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Hydroxyapatite-coated strain gauges for long-term in vivo bone strain measurements.
    Maliniak MM; Szivek JA; DeYoung DW; Emmanual J
    J Appl Biomater; 1993; 4(2):143-52. PubMed ID: 10171661
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Extended bioactivity in the proximity of hydroxyapatite ceramic surfaces induced by polarization charges.
    Nakamura S; Kobayashi T; Yamashita K
    J Biomed Mater Res; 2002 Sep; 61(4):593-9. PubMed ID: 12115449
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of plasma-sprayed hydroxyapatite coatings and zirconia-reinforced hydroxyapatite composite coatings: in vivo study.
    Lee TM; Yang CY; Chang E; Tsai RS
    J Biomed Mater Res A; 2004 Dec; 71(4):652-60. PubMed ID: 15505828
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Improved osseointegration of PTFEP-coated titanium implants.
    Zeifang F; Grunze M; Delling G; Lorenz H; Heisel C; Tosounidis G; Sabo D; Simank HG; Holstein JH
    Med Sci Monit; 2008 Feb; 14(2):BR35-40. PubMed ID: 18227757
    [TBL] [Abstract][Full Text] [Related]  

  • 26. In vivo evaluation of plasma-sprayed titanium coating after alkali modification.
    Xue W; Liu X; Zheng X; Ding C
    Biomaterials; 2005 Jun; 26(16):3029-37. PubMed ID: 15603798
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Early bone apposition in vivo on plasma-sprayed and electrochemically deposited hydroxyapatite coatings on titanium alloy.
    Wang H; Eliaz N; Xiang Z; Hsu HP; Spector M; Hobbs LW
    Biomaterials; 2006 Aug; 27(23):4192-203. PubMed ID: 16618502
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Sphene ceramics for orthopedic coating applications: an in vitro and in vivo study.
    Ramaswamy Y; Wu C; Dunstan CR; Hewson B; Eindorf T; Anderson GI; Zreiqat H
    Acta Biomater; 2009 Oct; 5(8):3192-204. PubMed ID: 19457458
    [TBL] [Abstract][Full Text] [Related]  

  • 29. In vivo study on biocompatibility and bonding strength of hydroxyapatite-20vol%Ti composite with bone tissues in the rabbit.
    Chu CL; Xue XY; Zhu JC; Yin ZD
    Biomed Mater Eng; 2006; 16(3):203-13. PubMed ID: 16518019
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical and histomorphometric study on the bone-screw interface of bioactive ceramic-coated titanium screws.
    Lee JH; Ryu HS; Lee DS; Hong KS; Chang BS; Lee CK
    Biomaterials; 2005 Jun; 26(16):3249-57. PubMed ID: 15603820
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of a prostaglandin EP4 receptor agonist on early fixation of hydroxyapatite/titanium composite- and titanium-coated rough-surfaced implants in ovariectomized rats.
    Hayashi K; Fotovati A; Abu Ali S; Nakamura Y; Inagaki M; Naito M
    J Biomed Mater Res A; 2010 Mar; 92(3):1202-9. PubMed ID: 19322876
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The correlation between osseointegration and bonding strength at the bone-implant interface: In-vivo & ex-vivo investigations on hydroxyapatite and hydroxyapatite/titanium coatings.
    Ghadami F; Amani Hamedani M; Rouhi G; Saber-Samandari S; Mehdi Dehghan M; Farzad-Mohajeri S; Mashhadi-Abbas F
    J Biomech; 2022 Nov; 144():111310. PubMed ID: 36162145
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biological performance of chemical hydroxyapatite coating associated with implant surface modification by laser beam: biomechanical study in rabbit tibias.
    Faeda RS; Tavares HS; Sartori R; Guastaldi AC; Marcantonio E
    J Oral Maxillofac Surg; 2009 Aug; 67(8):1706-15. PubMed ID: 19615586
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Histomorphometric evaluation of alumina-blasted/acid-etched and thin ion beam-deposited bioceramic surfaces: an experimental study in dogs.
    Suzuki M; Guimaraes MV; Marin C; Granato R; Gil JN; Coelho PG
    J Oral Maxillofac Surg; 2009 Mar; 67(3):602-7. PubMed ID: 19231787
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Histological and biomechanical evaluation of phosphorylcholine-coated titanium implants.
    Susin C; Qahash M; Hall J; Sennerby L; Wikesjö UM
    J Clin Periodontol; 2008 Mar; 35(3):270-5. PubMed ID: 18269667
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Plasma-sprayed coatings of tetracalciumphosphate, hydroxyl-apatite, and alpha-TCP on titanium alloy: an interface study.
    Klein CP; Patka P; van der Lubbe HB; Wolke JG; de Groot K
    J Biomed Mater Res; 1991 Jan; 25(1):53-65. PubMed ID: 1850430
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Quantitative analysis of in vivo tissue responses to titanium-oxide- and hydroxyapatite-coated titanium alloy.
    Hayashi K; Uenoyama K; Matsuguchi N; Sugioka Y
    J Biomed Mater Res; 1991 Apr; 25(4):515-23. PubMed ID: 2050714
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Enhanced bone regeneration by electrical polarization of hydroxyapatite.
    Itoh S; Nakamura S; Nakamura M; Shinomiya K; Yamashita K
    Artif Organs; 2006 Nov; 30(11):863-9. PubMed ID: 17062109
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of modifications of dual acid-etched implant surfaces on periimplant bone formation. Part II: calcium phosphate coatings.
    Schliephake H; Aref A; Scharnweber D; Rösler S; Sewing A
    Clin Oral Implants Res; 2009 Jan; 20(1):38-44. PubMed ID: 19126106
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Bone formation on apatite-coated titanium with incorporated BMP-2/heparin in vivo.
    Ishibe T; Goto T; Kodama T; Miyazaki T; Kobayashi S; Takahashi T
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Dec; 108(6):867-75. PubMed ID: 19782617
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.