These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

87 related articles for article (PubMed ID: 17271241)

  • 1. A 96-channel neural stimulation system for driving AIROF microelectrodes.
    Hu Z; Troyk P; Cogan S
    Conf Proc IEEE Eng Med Biol Soc; 2004; 2004():4244-7. PubMed ID: 17271241
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A laboratory testing and driving system for AIROF microelectrodes.
    Srivastava NR; Troyk PR; Cogan SF
    Conf Proc IEEE Eng Med Biol Soc; 2004; 2004():4271-4. PubMed ID: 17271248
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes.
    Cogan SF; Troyk PR; Ehrlich J; Plante TD; Detlefsen DE
    IEEE Trans Biomed Eng; 2006 Feb; 53(2):327-32. PubMed ID: 16485762
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intrinsic activation of iridium electrodes over a wireless link.
    Hu Z; Troyk P; DeMichele G; Kayvani K; Suh S
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():2788-91. PubMed ID: 23366504
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Activated iridium oxide film (AIROF) electrodes for neural tissue stimulation.
    Frederick RA; Meliane IY; Joshi-Imre A; Troyk PR; Cogan SF
    J Neural Eng; 2020 Oct; 17(5):056001. PubMed ID: 32947268
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation.
    Cogan SF; Guzelian AA; Agnew WF; Yuen TG; McCreery DB
    J Neurosci Methods; 2004 Aug; 137(2):141-50. PubMed ID: 15262054
    [TBL] [Abstract][Full Text] [Related]  

  • 7. "Safe" charge-injection waveforms for iridium oxide (AIROF) microelectrodes.
    Troyk PR; Detlefsen DE; Cogan SF; Ehrlich J; Bak M; McCreery DB; Bullara L; Schmidt E
    Conf Proc IEEE Eng Med Biol Soc; 2004; 2004():4141-4. PubMed ID: 17271213
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessing polarization of AIROF microelectrodes.
    Troyk PR; Hu Z; Cogan SF
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1726-9. PubMed ID: 18002309
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro comparison of the charge-injection limits of activated iridium oxide (AIROF) and platinum-iridium microelectrodes.
    Cogan SF; Troyk PR; Ehrlich J; Plante TD
    IEEE Trans Biomed Eng; 2005 Sep; 52(9):1612-4. PubMed ID: 16189975
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of electrolyte composition on the in vitro charge-injection limits of activated iridium oxide (AIROF) stimulation electrodes.
    Cogan SF; Troyk PR; Ehrlich J; Gasbarro CM; Plante TD
    J Neural Eng; 2007 Jun; 4(2):79-86. PubMed ID: 17409482
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 16-Channel biphasic current-mode programmable charge balanced neural stimulation.
    Li X; Zhong S; Morizio J
    Biomed Eng Online; 2017 Aug; 16(1):104. PubMed ID: 28806960
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vitro and in vivo charge capacity of AIROF microelectrodes.
    Hu Z; Troyk PR; Brawn TP; Margoliash D; Cogan SF
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():886-9. PubMed ID: 17946869
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A portable neurostimulator circuit with anodic bias enhances stimulation injection capacity.
    Ersöz A; Kim I; Han M
    J Neural Eng; 2022 Oct; 19(5):. PubMed ID: 36067737
    [No Abstract]   [Full Text] [Related]  

  • 14. Fabrication and electrochemical comparison of SIROF-AIROF-EIROF microelectrodes for neural interfaces.
    Kang XY; Liu JQ; Tian HC; Yang B; NuLi Y; Yang CS
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():478-81. PubMed ID: 25570000
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An Automatic Monitor System for AIROF Microelectrodes.
    Hu Z; Troyk P; Cogan S
    Conf Proc IEEE Eng Med Biol Soc; 2005; 2005():7386-8. PubMed ID: 17281987
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vivo and in vitro differences in the charge-injection and electrochemical properties of iridium oxide electrodes.
    Cogan SF
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():882-5. PubMed ID: 17946868
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electrodeposited iridium oxide for neural stimulation and recording electrodes.
    Meyer RD; Cogan SF; Nguyen TH; Rauh RD
    IEEE Trans Neural Syst Rehabil Eng; 2001 Mar; 9(1):2-11. PubMed ID: 11482359
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro and in vivo evaluation of PEDOT microelectrodes for neural stimulation and recording.
    Venkatraman S; Hendricks J; King ZA; Sereno AJ; Richardson-Burns S; Martin D; Carmena JM
    IEEE Trans Neural Syst Rehabil Eng; 2011 Jun; 19(3):307-16. PubMed ID: 21292598
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Chronic stability of activated iridium oxide film voltage transients from wireless floating microelectrode arrays.
    Frederick RA; Shih E; Towle VL; Joshi-Imre A; Troyk PR; Cogan SF
    Front Neurosci; 2022; 16():876032. PubMed ID: 36003961
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro study of iridium electrodes for neural stimulation.
    Aryan NP; Brendler C; Rieger V; Schleehauf S; Heusel G; Rothermel A
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():819-22. PubMed ID: 23366018
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.